The P56201BUF thermostat is designed for controlling underfloor heating. Important • Read the thermostat manual carefully before using the device for the first time. • Turn off power before installing the thermostat! • Follow prescribed standards during installation. GB | 2...
Technical specifications 86 mm 43 mm Switched load: max. 230 V AC; 16 A for resistive load Temperature measurement: 0 °C to 95 °C, 0.5 °C resolution Temperature setting: 1 °C to 70 °C, in 0.5 °C increments Temperature differential setting: 0.5 °C to 2.5 °C, in 0.5 °C increments Calibration of set temperature: -9 °C to 9 °C, in 1 °C increments...
Description of the Thermostat Screen – Icons and Buttons GB | 4...
Page 5
1 – The indicates the day of the week. 2 – Number of the day of the week (1 – Monday, 2 – Tuesday, 3 – Wednesday, 4 – Thursday, 5 – Friday, 6 – Saturday, 7 – Sunday). 3 – The icon appearing on the screen indicates that the screen is showing the temperature you have set for the given mode.
Installing the Thermostat Attention: Before changing the thermostat, disconnect the heating system from the mains power in your flat. This will prevent potential injury by electric current. Placement of the Thermostat The placement of the thermostat significantly affects its functioning. Choose a location where members of the family spend most of their time, preferably on the inside wall where air circulates freely, with no direct sunlight.
Mobile Application The thermostat can be controlled using a mobile application for iOS or Android. Download the EMOS GoSmart app for your device. Tap the Log In button if you‘ve used the app before. Otherwise, tap the Sign Up button and register.
Page 9
• Allows setting up to 6 time periods for each type of day. Time periods can be set in the Weekly Mode Settings tab in the EMOS GoSmart app. For each time period, set the temperature that should be set on the thermostat from the time you specify in time period settings.
• Example: The thermostat shows room temperature of 22 °C; setting calibration to +1 °C will cause the thermostat to display 23 °C instead. • Calibration can be set in EMOS GoSmart in a range of -9 °C to 9 °C with 1 °C resolution. Temperature Differential •...
Page 11
Temporary Manual Mode • Temporary manual mode activates if Weekly Mode is set on the thermostat and you press the arrow. • When it is active, the screen will show both the Weekly Mode and Manual Mode icon. • This mode is turned off only by changing to a different mode. Holiday Mode •...
Page 12
• A3 – Screen child lock • Can be set to 0 or 1. • 0 = lock off. • 1 = lock on. • The default value is 0. • A4 – Status of the device after reconnecting to power after a power outage •...
Page 13
Setting B Modes and Functions on an Inactive Thermostat Screen Turn off the thermostat screen using the button. When the screen is off, only the bottom bar of buttons is active. To access the thermostat’s advanced settings (B), press and hold the button for 3 seconds.
Troubleshooting FAQ The screen displays: E1 – fault of the indoor temperature sensor. • Reset the thermostat. • Return the thermostat. E2 – fault of the floor sensor. • Reset the thermostat. • Check that the sensor is connected properly. Check the settings of the active sensor in the thermostat’s menu.
Upkeep and Maintenance The product is designed to serve reliably for many years if used properly. Here are some tips for proper operation: • Read the manual carefully before using this product. • Do not expose the product to direct sunlight, extreme cold, humidity and sudden changes in temperature. This would reduce measuring accuracy.
Need help?
Do you have a question about the P56201BUF and is the answer not in the manual?