Lojer Capre E1 Instructions For Use Manual

Examination tables
Hide thumbs Also See for Capre E1:

Advertisement

Quick Links

Lojer Capre E1, E2 examination
tables
Instruction for use
ID: DX012187, rev. 2 / 12.10.2023 (en)
Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Capre E1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lojer Capre E1

  • Page 1 Lojer Capre E1, E2 examination tables Instruction for use ID: DX012187, rev. 2 / 12.10.2023 (en) Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 2: Table Of Contents

    This document is a translation of the original English version. In case of conflict, the original English version applies. Lojer Group is leading producers of medical furniture and physiotherapy equipment in Nordic Countries. We design and manufacture medical and treatment furniture to be used by health care professionals in various operating environments.
  • Page 3: Lojer Capre E Tables

    A Patient/ Client is a person in need of treatment or therapy given by a healthcare professional. Intended clinical benefits Indications for examination are typically symptoms of a disease or sensation of pain. Lojer 4040X Examination Table provides a support for a patient when these symptoms are examined by health care professional.
  • Page 4: Description Of Parts

    1.4 Description of parts The sections of Lojer Capre E examination tables are shown below. Figure 1: Lojer Capre E1 examination table Lying surface Castors (accessory) Central locking pedal Place free height adjustment bar (accessory) IV-pole mounting adapter (accessory) Figure 2: Lojer Capre E2 examination table...
  • Page 5: Options And Accessories

    1.5 Options and accessories Options and accessories available for Lojer Capre E examination tables: • Place free height adjustment bar (standard in FX-models) • Castors • IV-pole mounting adapter • Paper roll holder • Neck cushion • Skai Clinica upholstery •...
  • Page 6 Store in a dry place (package label) Temperature limits for transportation and storage Manufacturer Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 7: Introduction

    If the floor is uneven, the table might tilt. This can be corrected with adjustment pad included in the delivery. Each tube has a slot into which the pad can be screwed to achieve desired height. Figure 4: Levelling the table Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 8: Safety Instructions

    For safety reasons lock the device or unplug the power cord when the device is left unsupervised WARNING! The safe working load (SWL) is the maximum load including the patient and possible accessories. Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 9: Using The Device

    3.1 Adjustment range Adjustment range of the Capre E tables is shown below: Figure 5: Adjustment range of the Lojer Capre E tables 3.2 Central locking Castors with central locking are available as an option for Capre E examination tables. In order to free the locking, refract the pedal on either side of the table and press it down (Error! Reference source not found.).
  • Page 10: Height Adjustment

    SQUEEZING HAZARD! Make sure that under any circumstances the patient doesn’t accidentally move/touch any control device or the place free height adjustment bar. If necessary, use the safety switch. Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 11: Back Section

    If necessary use the safety switch. SQUEEZING HAZARD! Make sure that nothing is or gets between the structure or under the device during lifting/lowering. Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 12: Options And Accessories

    Install the pole to the adapter and lock it by releasing the lever (2). Lift the release ring on the pole (3) to adjust the height. Release the ring to lock the pole on the suitable height. Figure 12: IV-pole and adapter Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 13: Cleaning And Disinfecting

    Always clean the device between patients. ➔ Take into consideration facility-specific cleaning and disinfecting instructions when cleaning the device. • Any surface should not be subject to long-term exposure by any type of liquids. Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 14: Frame And Other Hard Surfaces

    For example, peroxygen or chlorine-based substances can be used to clean and disinfect secretion stains. Clean and disinfect the device’s castors when they have been visibly contaminated. ➔ • Allow the surfaces to fully dry before using or storing the device. Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 15: Maintenance

    Check and lubricate the following parts once a year or more often if necessary. • Joints • Bearings • Bearing points of the underside rods Check all frame parts and joint to identify any fractures, rust or other damages. Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 16: Troubleshooting

    The actuator might stop working. overloaded. Contact the service. In order to change the actuators, controls or control box and ordering other spare parts contact the Lojer Service. Before contacting, find out the following information from the type plate of the device: •...
  • Page 17 Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 18: Technical Information

    Oils must be removed from the hydraulic system and dispose these oils in an appropriate waste processing plant. The gas spring must be depressurized and the oils removed before being collected to metal waste. Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 19 PVC waste is sent separately to a waste center or to a sorting station. PVC plastic is known from the sign below, material number 03. The pre-treated and sorted materials are delivered to special collection points. Always follow regional and collection point specific instructions. Recycling can significantly reduce soil waste. Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 20: Circuit Diagram

     Switch box (related to place R20518 free height adjustment bar)  Hand control R284HB30 Foot control R284FS3CFN  Battery R284BA19  Adapter MHB R284MJB0005 Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 21: Electromagnetic Compatibility (Emc)

    6.4.1 Electromagnetic emission Medical device (Lojer 4040XL) is intended for use in the electromagnetic environment specified below. The customer or the user of the medical device should assure that it is used in such an environment.
  • Page 22: Electromagnetic Immunity

    0° Magnetic field at Magnetic fields at mains frequency should supply frequency (50/60 30 A/m 30 A/m corresponds to the typical values present in commercial and hospital environment. IEC 61000-4-8 Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 23 Note 1. At 80MHz and 800MHz the higher frequency range applies. Note 2. These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 24: Limited International Warranty

    7 Limited International Warranty The terms of the warranty for the product are set out in the contract documents of the purchase. Unless otherwise agreed, the general warranty terms apply (see www.lojer.com or contact our service service@lojer.com). Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...
  • Page 25: Contact Information

    Email: firstname.lastname@lojer.com info@lojer.com www.lojer.com Copyright © Lojer Oy, 2023 | 2/20203 Your local Lojer dealer, see www.lojer.com/distributors Model: ________________________________________________________ Serial number: __________________________________________________ Date of purchase: ________________________________________________ Your local Lojer dealer:____________________________________________ Copyright © Lojer Group ID: DX012187 Version: 2 Date: 12.10.2023...

This manual is also suitable for:

Capre e2

Table of Contents