PROBLEMS
The blades are blocked in a
different position from the required
one.
After the opening control, the
blades are in a partially opened
position at about 33%.
The blades are blocked in a
partially opened position of about
33%, and don't move.
The blades are blocked in a
partially blocked position of about
66%, and don't move.
The blades do not open when there
is a strong wind.
Malfunction not included among
the above.
www.gibus.com
CAUSES
Something has fallen into the movement
area and blocks the movement: side tracks,
perimeter gutters, etc.
Less than 6 hours have passed since the rain
has stopped and the rain alarm is active.
At least 60 seconds have passed from the
detection of wind beyond the set threshold;
the wind alarm is enabled.
The temperature is lower than 2°C and the
alarm is enabled; if it is also raining and the
snow sensor is enabled.
Wind sensor sensitivity programmed for a
too high limit.
Anemometer incorrectly wired to the control
unit.
Faulty anemometer.
USE AND MAINTENANCE MANUAL
REMEDIES
Move the blades with the "man present"
command and/or remove the foreign
body that is blocking them.
Control the opening with the operator
present or disable the rain sensor
(chapter 2).
Wait for the breeze decreases.
Control the displacement with the
operator present.
Reprogram the anemometer limits.
Check the connections to the terminals.
Replace the anemometer.
Check the specific instruction manuals
for the control units attached to this
manual, or contact the technical service
centre.