Read in particular the chapter on safety. Dear Customer, thank you for choosing a Pergola by "Gibus", we are pleased to deliver this manual in order to help you to use the product in the best possible way. Please read carefully the recommendations described in the following pages and keep the manual at hand for the Gibus specialist who will be responsible for management and maintenance of the Pergola.
Page 4
Rev. 3 These instructions were translated from Italian (original language). Gibus S.p.A. reserves all rights to this manual, including the right, at any time, to make any necessary changes aimed at improving its products and the manual itself without prior notice.
3.6 Biocidal products 3.7 Noise level 4 TECHNICAL DATA 4.1 Type 4.2 AZIMUT ISLAND 4.3 AZIMUT FRONTAL LEANING VERSION 4.4 AZIMUT LATERAL LEANING VERSION 4.5 Coupling module 4.6 AZIMUT side drop awnings 5 PACKING, HANDLING AND TRANSPORTATION 6 SAFE INSTALLATION 6.1 Mechanical structure...
Page 6
10 DISASSEMBLY AND DISPOSAL 10.1 Disposing of the Pergola TROUBLESHOOTING 11.1 Faults and failures table 12 CONVENTIONAL WARRANTY UP TO THE FIFTH YEAR 13 AZIMUT EXPLODED DRAWING 13.1 1 MODULE 13.2 COUPLING MODULE TYPE 1 13.3 COUPLING MODULE TYPE 2 13.4 CROSS-SHAPED COUPLING 13.5 FABRIC COVER...
(blinds with zip system), available single or multi-module, with coupling modules. - AZIMUT LEANING VERSION: drop awning leaning against the wall with retractable stretched cloth and built-in side drop awnings (blinds with zip system), available single or multi-module, with coupling modules.
UNI EN 13561 and the self-certification document (Declaration of Performance DoP) are included in APPENDIX 0 and APPENDIX 1 on the last pages of this manual. The original Declaration of Performance DoP issued by the manufacturer is kept by Gibus S.p.A. 1.3.2 With reference to UKCA marking This User’s Manual was prepared according to EN 13561 and the “Supply of Machinery (Safety)
Code 340411 Rev. 3 RESPONSIBILITY Gibus SpA is not liable and has no obligations for any accidents to persons or property, which may occur due to: - Failure to follow the instructions in this manual regarding the installation, use and maintenance of the Pergola;...
IMPORTANT: In order to use the awning for purposes other than those described above, a specific permission given by the manufacturer is required. Failure to follow the conditions for proper use, automatically voids any warranty given by the manufacturer. USE AND MAINTENANCE MANUAL www.gibus.com Page...
The installation of the awning must be carried out strictly in accordance with the manufacturer's instructions provided in this manual and especially following the attached Installation Instructions referred to in the pertinent sections of this manual (Chap. 6 and Chap. 7). USE AND MAINTENANCE MANUAL www.gibus.com Page...
- If the structure leans against an existing building, carry out the lighting hazard assessment again in accordance with Law Decree 81/08 (in chapter III of Title III) by applying the technical reference regulations such as CEI EN 62305-2 (CEI 81-10/2). USE AND MAINTENANCE MANUAL www.gibus.com Page...
Rev. 3 CHAPTER 3: TECHNICAL DESCRIPTION The drop awnings of the AZIMUT line were designed and built according to the principles of constant innovation, impeccable workmanship and attention to the details of Gibus Total Quality. A system of values designed to ensure complete customer satisfaction.
ELECTRICAL COMPONENTS The AZIMUT motors (and the motors of the side blinds) are tubulars single-phase asynchronous irreversible equipped with thermal protection at 140°C for safety devices against overheating. They are equipped with a condenser, electromechanical brake assembly, two limit switches and mechanical scaler for the reduction of primary turns at 12 or 17 [rev/min] ouputs.
The type of electronic component used on the Pergola is indicated in the product sheet. CAUTION: Never set the wind speed above the wind resistance of the awning itself (maximum threshold recommended for AZIMUT: 60 Km/h; perimeter drop awnings: 40 km/h).
Page 17
Screen fabric made of 25% polyester (internal) and 75% PVC (external). Screen fabric for outdoor protection from the sun, thickness 0.8 mm, weight approximately 510 g/m (ISO 2286-2), Tensile strength warp approximately 105 daN/5cm, weft approximately 100 daN/5cm, Fireproof Class 1 (IT: UNI 9177) B1 (DE: DIN 4102-1). USE AND MAINTENANCE MANUAL www.gibus.com Page...
ATTENTION: Some of the fabrics used by Gibus to package its products undergo treatments with biocidal products. For more information and to know the type of biocidal product possibly used in treating the fabric of your awning please visit our website: www.gibus.com...
600 cm With 6 legs: width up to 600 cm projection up to 740 cm AZIMUT FRONTAL LEANING VERSION (Basic Module) Tubular motor parallel to the wall With 2 legs: width up to 600 cm projection up to 600 cm...
Code 340411 Rev. 3 AZIMUT ISLAND 4 legs 6 legs ISLAND - SINGLE MODULE 4 LEGS max. L x S 6.00 x 6.00 6 LEGS max. L x S 6.00 x 7.40 Side view Front View WIDTH “L ” (cm) 1 Module n°...
Page 21
Fully packed cloth, even the largest sizes, offer a snow resistance of 100 kg/m or more. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Code 340411 Rev. 3 AZIMUT FRONTAL LEANING VERSION 2 legs 4 legs FRONTAL LEANING VERSION - SINGLE MODULE 2 LEGS max. L x S 6.00 x 6.00 4 LEGS max. L x S 6.00 x 7.40 Side view Front View WIDTH “L ”...
Page 23
Fully packed cloth, even the largest sizes, offer a snow resistance of 100 kg/m or more. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Code 340411 Rev. 3 AZIMUT LATERAL LEANING VERSION 2 legs 3 legs LATERAL LEANING VERSION - SINGLE MODULE 2 LEGS max. S x L 6.00 x 6.00 3 LEGS max. S x L 6.00 x 7.40 Side view Front View PROJECTION “S”...
Page 25
Fully packed cloth, even the largest sizes, offer a snow resistance of 100 kg/m or more. USE AND MAINTENANCE MANUAL www.gibus.com Page...
The coupling units can be placed laterally or head on to the basic module; it is possible to couple one or more modules. The drawings shown below are just an example. AZIMUT ISLAND WITH COUPLING MODULE TYPE 1 COUPLING Up to 600 cm.
Page 27
Code 340411 Rev. 3 AZIMUT FRONTAL LEANING VERSION WITH COUPLING MODULE TYPE 1 COUPLING Up to 600 cm. From 601 cm to 740 cm. AZIMUT FRONTAL LEANING VERSION WITH COUPLING MODULE TYPE 2 COUPLING Up to 600 cm. From 601 cm to 740 cm.
Page 28
Code 340411 Rev. 3 AZIMUT LATERAL LEANING VERSION WITH COUPLING MODULE TYPE 2 COUPLING Up to 600 cm. From 601 cm to 740 cm. The width of the TYPE 2 coupled module is different than the extension of the base module because the coupled module does not consider the overall 17 cm dimensions of the coupling leg.
Side drop awnings can be assembled on a AZIMUT structure already installed. Legend: Kg = total weight of the drop awning. LT = WIDTH of AZIMUT side (cm) - NOTE: for the width of the fabric subtract 34 [cm]. HG = Height up to the gutter. LEGEND - “BEAUFORT” WIND SCALE...
(and the fabric of the side drop awnings). Do not use cutters. The packaging material should be disposed of or recycled in accordance with the regulations in force in the Country of destination of the product. USE AND MAINTENANCE MANUAL www.gibus.com Page...
“Instructions for proper installation” in Chapter 7. At the time of installation arrange all the tools mentioned on the first pages of the “Installation Instructions - AZIMUT line”. If installers are more than one, it is necessary to appoint an operations co-ordinator.
The manufacturer refuses all liabilities for damage caused by the improper use of system devices or for uses that are not given in this instruction manual. For further information, please contact Technical Support. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 33
IMPORTANT! The wiring diagrams and instructions for the use of engines and electronic control units are annexed to the control units themselves and should accompany this manual along with the Installation Instructions and carefully stored for subsequent consultations. USE AND MAINTENANCE MANUAL www.gibus.com Page...
▼. to increase intensity, long press ▲. In case of side drop awnings, the latter can be operated by the same remote control (by selecting the appropriate channel), or with dedicated remote control. USE AND MAINTENANCE MANUAL www.gibus.com Page...
1st engine and power up the 2nd, repeat the programming and so on. IMPORTANT: after installation the declaration for proper installation must be compiled by the installer (Sec. 14 par. 1). USE AND MAINTENANCE MANUAL www.gibus.com Page...
For the sake of safety, it is therefore strictly required to pull the cloth back (rewinding any side closures) long before exceeding the aforementioned limit. If there is no sensor, pack the cloth (and rewind any side closures) if there is a strong wind. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 37
Gibus original spare parts. If the awning is equipped with an anemometric sensor, never set the wind speed above the wind resistance of the awning itself (maximum threshold recommended for AZIMUT: 60 Km/h; perimeter drop awnings: 40 km/h). ATTENTION! In the case of fault or when searching for faults, respect the safety measures.
IMPORTANT! The extended fabric cover should always be tensioned, so you will prevent the fabric from “banging” at every breath of wind. IMPORTANT! Failure to follow the conditions for proper use, automatically voids any warranty given by the manufacturer. USE AND MAINTENANCE MANUAL www.gibus.com Page...
2nd year from the installation of the awning; this will extend the warranty up to the 5th year. If this is not done, the Gibus warranty will no longer be valid. Use original Gibus spare parts; otherwise, the warranty will be voided.
REMOVE ANYTHING THAT OBSTRUCTS THE WATER DOWNFLOW, REMOVING ANY FOREIGN PARTS. □ ____ CHECK THE SEALS (GUTTER PLUGS, COLUMN DRAIN COUPLINGS, PROTECTIVE COVER FOR THE qualified and trained personnel. Call for a Gibus specialised CLOSED FABRIC). □ ____ CHECK THE BEARING STRUCTURE...
CHAPTER 10: DISMANTLING AND DISPOSAL CAUTION: dismantling of the Pergola must be carried out by qualified and trained staff. Ask for a specialized Gibus technician at the Service Department. CAUTION: dismantling of the Pergola must be carried out applying all the safety provisions as per installation: see chapter “SAFE INSTALLATION”...
The engine does not start up. Check the operation of Faulty engine. the engine and replace if necessary The motor stops after 4-5 Allow the engine to cool minutes after continuous Thermal protection of the motor triggers. down. running USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 43
The awning closes and opens Calibration of too sensitive values. Trimmer Adjust the calibration and frequently. adjusted in DEMO mode. sensitivity values. Low battery. Replace the battery. Faulty remote control. Faulty remote control. Replace the remote control. USE AND MAINTENANCE MANUAL www.gibus.com Page...
The Gibus conventional guarantee covers the cost of spare parts in the following percentages: · In the 3rd year, the Guarantee covers 60% of the value of the spare part determined by the price shown by Gibus on the sales invoice to the dealer or, if not specifically stated therein, by the price charged for the spare part at the time of sale to the dealer;...
Page 45
The Gibus conventional guarantee will be recognized only if there is the Gibus hologram and “serial number” and after Gibus has checked for the compliance with the requirements and conditions set out in this chapter and in the “Use and maintenance manual””...
Use Gibus original spare parts to keep the warranty valid. Accordingly, a compulsory maintenance operation within the end of the 3rd year from the installation date is to be required to the Gibus specialized technician and that will extend the warranty to the 4th year; a compulsory maintenance in the 4th year from the installation date will extend the warranty to the 5th year.
Page 52
Code 340411 Rev. 3 ADDITIONAL Installation Notes: ADDITIONAL Mandatory Maintenance Notes: USE AND MAINTENANCE MANUAL www.gibus.com Page...
Code 340411 Rev. 3 14.2 MAINTENANCE AND NOTE REGISTER Operation description Full name and signature Date (including components replacement) specialized technician USE AND MAINTENANCE MANUAL www.gibus.com Page...
Code 340411 Rev. 3 Operation description Full name and signature Date (including components replacement) specialized technician NOTES: 14.3 PRODUCTION NOTES See the product sheet attached to the back cover. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 55
Code 340411 Rev. 3 laterali chiusure USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 56
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 57
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 58
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 59
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 60
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 61
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 62
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 63
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 64
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 65
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 66
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
Page 67
Mandatory maintenance within the end of the 4th year date: Stamp and signature Gibus technician: (*) The declaration of correct installation given by Gibus’ specialized technician is essential for the warranty to remain Recommended maintenance within the end of the 5th year date: Stamp and signature Gibus valid.
2. Serial number: see the HOLOGRAM on the back cover 3. Designed use: Drop awning for outdoor use 4. Name and address of the manufacturer: Gibus S.p.A. - Via Einaudi, 35 - 35030 Saccolongo www.gibus.it - E-mail: gibus@gibus.it 6. Assessment and check system of constant performance: System 4 9.
Page 69
2. Serial number: see the HOLOGRAM on the back cover 3. Designed use: Drop awning for outdoor use 4. Name and address of the manufacturer: Gibus S.p.A. - Via Einaudi, 35 - 35030 Saccolongo www.gibus.it - E-mail: gibus@gibus.it 6. Assessment and check system of constant performance: System 4 9.
Need help?
Do you have a question about the AZIMUT and is the answer not in the manual?
Questions and answers