Table of Contents

Advertisement

Quick Links

USE AND MAINTENANCE MANUAL
DECLARATION OF QUALITY
DECLARATION OF WARRANTY
DECLARATION OF PERFORMANCE DoP
MODEL
VELVET PLUS
ISLAND VERSION, LEANING VERSION, SINGLE MODULE, COUPLED
Gibus S.p.A. Via Luigi Einaudi, 35 35030 Saccolongo (PD) - ITALY www.gibus.it - gibus@gibus.it
ENG
MUT 114
Code 340421
Rev. 1
30/10/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VELVET PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for Gibus VELVET PLUS

  • Page 1 DECLARATION OF QUALITY DECLARATION OF WARRANTY DECLARATION OF PERFORMANCE DoP MODEL VELVET PLUS ISLAND VERSION, LEANING VERSION, SINGLE MODULE, COUPLED MUT 114 Code 340421 Rev. 1 30/10/2022 Gibus S.p.A. Via Luigi Einaudi, 35 35030 Saccolongo (PD) - ITALY www.gibus.it - gibus@gibus.it...
  • Page 2: Coupling Module Type

    Code: 340421 Rev. 1 USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 3: Important Note

    Read in particular the chapter on safety. Dear Customer, thank you for choosing an awning by “Gibus”, we are pleased to deliver this manual in order to help you to use the product in the best possible way. Please read carefully the recommendations described in the following pages and keep the manual at hand for the Gibus specialist who will be responsible for management and maintenance of the awning.
  • Page 4 Rev. 1 These instructions were translated from Italian (original language). Gibus S.p.A. reserves all rights to this manual, including the right, at any time, to make any necessary changes aimed at improving its products and the manual itself without prior notice.
  • Page 5: Table Of Contents

    3.6 Biocidal products 3.7 Noise level 4 TECHNICAL DATA 4.1 Type 4.2 VELVET PLUS ISLAND 4.3 VELVET PLUS FRONTAL LEANING VERSION 4.4 VELVET PLUS LATERAL LEANING VERSION 4.5 Coupling module 4.6 VELVET PLUS side drop awnings 5 PACKING, HANDLING AND TRANSPORTATION 6 SAFE INSTALLATION 6.1 Mechanical structure...
  • Page 6 Art.12 FINAL REMARKS 13 VELVET EXPLODED DRAWING 13.1 1 MODULE 13.2 COUPLING MODULE TYPE 1 13.3 COUPLING MODULE TYPE 2 13.4 DROP AWNINGS VELVET PLUS 14 DOCUMENTATION 14.1 Declaration for correct installation 14.2 Maintenance registry 14.3 Production notes 15 ANNEXES...
  • Page 7: Chapter 1: Introduction

    Self-supporting or wall leaning version for outdoor use. Models: VELVET PLUS (ISLAND - LEANING VERSION) Published: Gibus S.p.A. via L. Einaudi, 35 - 35030 SACCOLONGO (PD) - ITALY http: www.gibus.it - e-mail: gibus@gibus.it List of annexes: Installation instructions - Motors and automatisms instructions - Delivery certificate.
  • Page 8: Regulations And Self-Certification Documentation

    (Declaration of Performance DoP) are included in APPENDIX 0 and APPENDIX 1 on the last pages of this manual. The original Declaration of Performance DoP issued by the manufacturer is kept by Gibus S.p.A. 1.3.2 With reference to UKCA marking This User’s Manual was prepared according to EN 13561 and the “Supply of Machinery (Safety) Regulations...
  • Page 9: Liability

    Code: 340421 Rev. 1 RESPONSIBILITY Gibus SpA is not liable and has no obligations for any accidents to persons or property, which may occur due to: - Failure to follow the instructions in this manual regarding the installation, use and maintenance of the Pergola;...
  • Page 10: Chapter 2: Safety Requirements

    (*) The VELVET PLUS pergola is designed to withstand, with the blades in the closed position, a static load from deposited snow 50 kg/m (without wind).
  • Page 11: Use Environment

    (Km/h): DIP 1 DIP 2 DIP 3 Km/h The alarm is off when the sensor detects for 60 seconds a speed lower than the set threshold. Alarm priority: HIGH. The default sensor is ENABLED. USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 12 Press the STOP key on the transmitter 10 times, keeping it pressed for the tenth time for 2˝. The The buzzer emits 2 beeps. buzzer emits for 4˝. a continuous sound. STOP STOP ˝ 4˝ USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 13: Requirements Of The User And Installer

    ˝ 4˝ Electronic antifreeze system in the gutter: The Gibus antifreeze system is a system for heating the upper surface of the gutters and is able to prevent the formation and/or excessive accumulation of snow in the gutter. ATTENTION: If the rain sensor is deactivated, the anti-snow system does not work.
  • Page 14: Chapter 3: Technical Description

    CEI EN 62305-2 (CEI 81-10/2). CHAPTER 3: TECHNICAL DESCRIPTION The Bioclimatic Pergola of the VELVET PLUS line were designed and built according to the principles of constant innovation, impeccable workmanship and attention to the details of Gibus Total Quality.
  • Page 15: Structural And Mechanical Components

    Blade Seal: Blades sealing system. STRUCTURAL AND MECHANICAL COMPONENTS The Gibus bioclimatic pergola is formed by a self-supporting structure or It is attached to a wall, made from painted aluminium and with side guides and built-in gutters, supporting legs measuring 170x170 mm, and cover formed by adjustable swinging brise soleil blades.
  • Page 16 Upstream a magnetothermal and differential switch must be installed with the characteristics defined in the table below. If there is more than one output line from the pergola, each single line must be protected. Provide power cables as defined in the table below. VELVET PLUS Electric Features Type Bioclimatic pergola.
  • Page 17: Electronic Components Of The Pergola (Optional)

    (see paragraph 2.3 and 2.4). CAUTION: Never set the wind speed above the wind resistance of the awning itself (maximum threshold recommended for VELVET PLUS: 60 Km/h). IMPORTANT: The installation and maintenance instructions of the control units and sensors are attached to the control unit packages, which are delivered along with the Bioclimatic Pergola or placed in the accessory box.
  • Page 18 IMPORTANT: the fabrics used are guaranteed for a period of 5 years in the case that the warranty is extended, following a normal exposure to the action of the sun and atmospheric agents in general, and the action of moulds and micro- organisms. USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 19: Complementary Materials

    ATTENTION: Some of the fabrics used by Gibus to package its products undergo treatments with biocidal products. For more information and to know the type of biocidal product possibly used in treating the fabric of your awning please visit our website: www.gibus.com...
  • Page 20: Chapter 4: Technical Data

    VELVET PLUS ISLAND (Basic Module) With 4 legs: Width up to 450 cm Projection up to 607 cm VELVET PLUS FRONTAL LEANING VERSION (Basic Module) Tubular motor parallel to the wall With 2 legs: Width up to 450 cm Projection up to 607 cm...
  • Page 21: Velvet Plus Island

    Code: 340421 Rev. 1 VELVET PLUS ISLAND ISLAND - SINGLE MODULE 4 LEGS max. L x S 4,50 x 6,07 Front View Side view WIDTH “L” (cm) Module n° n° Legend: kg = Total pergola weight including the supporting structure and brise soleil blades.
  • Page 22 Violent storm Storm Strong gale Gale High wind High wind Wind Resistance [kg/m Wind Resistance [kg/m Without Integrated ZIP Screens Integrated ZIP Screens closed or semi-closed on 2 or 4 sides “L” “L” “S” “S” USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 23: Velvet Plus Frontal Leaning Version

    Code: 340421 Rev. 1 VELVET PLUS FRONTAL LEANING VERSION FRONTAL LEANING VERSION - SINGLE MODULE 2 LEGS max. L x S 4,50 x 6,07 Side view Front View WIDTH “L” (cm) Module n° n° Legend: kg = Total pergola weight including the supporting structure and brise soleil blades.
  • Page 24 Storm Strong gale Gale High wind High wind Wind Resistance [kg/m Wind Resistance [kg/m Without Integrated ZIP Screens Integrated ZIP Screens closed or semi-closed on 2 or 4 sides “L” “L” “S” “S” 1045 USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 25: Velvet Plus Lateral Leaning Version

    Code: 340421 Rev. 1 VELVET PLUS LATERAL LEANING VERSION LATERAL LEANING VERSION SINGLE MODULE 2 LEGS max. S x L 4,50 x 6,07 Front View Side view WIDTH “L” (cm) Module n° n° Legend: kg = Total pergola weight including the supporting structure and brise soleil blades.
  • Page 26 Storm Strong gale Gale High wind High wind Wind Resistance [kg/m Wind Resistance [kg/m Without Integrated ZIP Screens Integrated ZIP Screens closed or semi-closed on 2 or 4 sides “L” “L” “S” “S” 1045 USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 27: Coupling Module

    VELVET PLUS ISLAND WITH COUPLING MODULE TYPE 2 COUPLING Projection Projection BASE COUPLED module module VELVET PLUS FRONTAL LEANING VERSION WITH COUPLING MODULE TYPE 1 COUPLING Width Width BASE COUPLED module module USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 28 Code: 340421 Rev. 1 VELVET PLUS FRONTAL LEANING VERSION WITH COUPLING MODULE TYPE 2 COUPLING Projection Projection BASE COUPLED module module VELVET PLUS LATERAL LEANING VERSION WITH COUPLING MODULE TYPE 1 COUPLING Projection Projection BASE COUPLED module module VELVET PLUS LATERAL LEANING VERSION WITH COUPLING MODULE TYPE 2 COUPLING...
  • Page 29: Velvet Plus Side Drop Awnings

    Legend: kg = total weight of the drop awning. LT = WIDTH of VELVET PLUS side (cm) - NOTE: for the width of the fabric subtract 34 [cm]. HG = Height up to the gutter. LEGEND - “BEAUFORT” WIND SCALE...
  • Page 30: Chapter 5: Packing, Handling And Transportation

    IMPORTANT: unpack using scissors with rounded tips in order not to damage aluminium painting, do not use cutters. The packaging material should be disposed of or recycled in accordance with the regulations in force in the Country of destination of the product. USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 31: Chapter 6: Safe Installation

    In particular follow the “Instructions for proper installation” in Chapter 7. At the time of installation arrange all the tools mentioned on the first pages of the “Installation Instructions - VELVET PLUS line”. If installers are more than one, it is necessary to appoint an operations co-ordinator.
  • Page 32: Electrical Connections

    IMPORTANT! Never connect two or more engines to one single switch / inverter without using a control unit. Do not connect the two switches / inverters to a single engine. There is a risk of induced currents resulting in damage to the engines. USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 33: Electrical Wiring And Connections Control Unit Velvet

    - The snow sensor (rain and temperature combined) must be activated. - The rain sensor is already activated. - The wind sensor is already activated. ATTENTION: The electronic board is protected by a 15A fuse. The maximum permitted power is 360W. USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 34 IMPORTANT!: The wiring diagrams and instructions for the use of engines and electronic control units are annexed to the control units themselves and should accompany this manual along with the Installation Instructions and carefully stored for subsequent consultations. USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 35: Electrical Wiring And Connections Control Unit Of Side Drop Awnings

    MOTOR 3 (CLOSE) FLASHING = WIND ALARM MOTOR 3 COMMON P1-P4 PROGRAMMING BUTTONS MOTOR 3 (OPEN) DESCRIPTION OF MOTOR AND SENSOR 230V WIRING COMPONENTS TUBULAR MOTORS WIND SENSOR CONTROL UNIT OF SIDE DROP AWNINGS USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 36: Radio Control

    CAUTION: The installation includes always several motors with remote control. Follow the “Installation Instructions” attached to this manual or enclosed in the accessory box or part of the packaging. USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 37: Chapter 8: Operation And Use Of The Pergola

    There could be a residual risk of crushing or trapping fingers (see the figure in Chapter 7). ATTENTION: for safety reasons before activating the VELVET PLUS side drop awnings, make sure that there are no person or objects that prevent the awning from opening or closing.
  • Page 38 NOTE: The 9 channel/63 position version is given as an example FULL OPENING/PACKING FROM ANY CHANNEL POSITION STOP FULL EXTENSION CHANNEL CLOSED (HORIZONTAL BLADES) CHANGE KEYS OPEN BLADES (ORIENTATION ABOUT 33%) OPEN BLADES (ORIENTATION ABOUT 66%) OPEN BLADES (ORIENTATION ABOUT 100%) USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 39 “b” of the transmitter to manage additional groups from 7 to 9 (a couple of leds turn on each channel). KEY “A”: KEY “B”: 1÷6 CHANNELS 7÷9 CHANNELS USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 40 Press a button relative to the code to be deleted within 5 seconds. Upon completion of deletion, the buzzer will stop. MEMORIZED MEMORIZED < 5˝ < 5˝ 1˝ Continuos sound Continuos sound Intermittent sound Keep pressed WITHIN 5” WITHIN 5” USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 41 Under the same circumstances rewind the side closures Screen VELVET PLUS. REMOTE DELETION OF A RADIO CODE...
  • Page 42 The radio control is programmed/matched during the installation of the awning. For more information on the procedure for programming and adjusting the endstops, refer to the attached “Installation Instructions” and the Instructions that are attached to the specific device. USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 43 Please roll up the side drop awnings Screen VELVET PLUS. IMPORTANT! If something has blocked the opening or closing of the blades, continue the opening or closing with the “man present”...
  • Page 44: Important Information On Use

    Rev. 1 IMPORTANT!: in the case of failures, turn to you dealer and if required only ask for Gibus original spare parts. ATTENTION! In the case of fault or when searching for faults, respect the safety measures. In particular when searching for or repairing any faults to the electric components, there is the risk or fatal electric shock.
  • Page 45: Chapter 9: Maintenance

    Compulsory maintenance required by the end of the 2 year and the following maintenance operations for extending the warranty year after year must be carried out by a Gibus technician and must minimally include an inspection of the correct blade movement, positioning of the endstops in opening and closing, making sure that the wind sensor is working if it is present and the conditions of the seals.
  • Page 46: Maintenance Of The Pergola

    CHAPTER 10: DISMANTLING AND DISPOSAL CAUTION: dismantling of the Pergola must be carried out by qualified and trained staff. Ask for a specialized Gibus technician at the Service Department. CAUTION: dismantling of the Pergola must be carried out applying all the safety provisions as per installation: see chapter “SAFE INSTALLATION”...
  • Page 47: Disposing Of The Pergola

    (guttering, etc.). This is extremely important when blades are moving. The following table shows the solution to more common problems. In the presence of problems other than those listed contact the Service Department. USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 48: Faults And Failures Table

    The continuous beep is not heard when No more than 1 second must pass between Keys pressed at incorrect times. a transmitter is being stored. pressing one key and the next. USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 49 Calibration of too sensitive values. Trimmer adjusted The awning closes and opens frequently. Adjust the calibration and sensitivity values. in DEMO mode. Low battery. Replace the battery. Faulty remote control. Faulty remote control. Replace the remote control. USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 50: Chapter 12: Conventional Warranty Up To The Fifth Year

    The Gibus conventional guarantee covers the cost of spare parts in the following percentages: • In the 3rd year, the Guarantee covers 60% of the value of the spare part determined by the price shown by Gibus on the sales invoice to the dealer or, if not specifically stated therein, by the price charged for the spare part at the time of sale to the dealer, •...
  • Page 51: Art.8 Territorial Extension

    Art.9 FURTHER CONDITIONS FOR THE VALIDITY OF THE CONVENTIONAL GUARANTEE In order for the Gibus conventional guarantee to be considered valid and effective pursuant to this document, in addition to the above, all the following additional conditions must be met: A.
  • Page 52: Chapter 13: Exploded Drawing Of Velvet Plus

    Code: 340421 Rev. 1 CHAPTER 13: EXPLODED DRAWING OF VELVET PLUS 13.1 1 MODULE USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 53: Coupling Module Type

    Code: 340421 Rev. 1 13.2 COUPLING MODULE TYPE 1 USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 54 Code: 340421 Rev. 1 13.3 COUPLING MODULE TYPE 2 USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 55: Drop Awnings Velvet Plus

    Code: 340421 Rev. 1 13.4 VELVET PLUS DROP AWNING USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 56: Chapter 14: Technical Notes

    Use Gibus original spare parts to keep the warranty valid. Accordingly, a compulsory maintenance operation within the end of the 3rd year from the installation date is to be required to the Gibus specialized technician and that will extend the warranty to the 4th year; a compulsory maintenance in the 4th year from the installation date will extend the warranty to the 5th year.
  • Page 57 Code: 340421 Rev. 1 ADDITIONAL Installation Notes: ADDITIONAL Mandatory Maintenance Notes: USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 58 Code: 340421 Rev. 1 USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 59: Maintenance Registry

    Code: 340421 Rev. 1 14.2 MAINTENANCE AND NOTE REGISTER Operation description Full name and signature Date (including components replacement) specialized technician NOTES: USE AND MAINTENANCE MANUAL www.gibus.com Page...
  • Page 60: Production Notes

    Code: 340421 Rev. 1 Operation description Full name and signature Date (including components replacement) specialized technician NOTES: 14.3 PRODUCTION NOTES See the product sheet attached to the back cover. USE AND MAINTENANCE MANUAL Page www.gibus.com...
  • Page 61 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 62 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 63 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 64 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 65 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 66 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 67 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 68 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 69 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 70 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 71 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 72 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 73 DECLARATION OF INSTALLATION (*) VELVET PLUS side drop awning Installation: Date: Stamp and signature Gibus technician: Installation Notes: Installation Notes: Mandatory maintenance Date: Stamp and signature Gibus within the end of the 2nd year technician: Mandatory maintenance Date: Stamp and signature Gibus...
  • Page 74: Chapter 15: Annexes

    Serial number: see the HOLOGRAM on the back cover Designed use: Bioclimatic Pergola with brise Solei for external use Name and address of the manufacturer: Gibus S.p.A. - Via Einaudi, 35 - 35030 Saccolongo www.gibus.it - E-mail: gibus@gibus.it Assessment and check system of constant performance: System 4...
  • Page 75 Serial number: see the HOLOGRAM on the back cover Designed use: Bioclimatic Pergola with brise Solei for external use Name and address of the manufacturer: Gibus S.p.A. - Via Einaudi, 35 - 35030 Saccolongo www.gibus.it - E-mail: gibus@gibus.it Assessment and check system of constant performance: System 4...
  • Page 76 HOLOGRAM Gibus S.p.A. via Luigi Einaudi, 35 35030 Saccolongo (PD) - ITALY www.gibus.it - gibus@gibus.it PRODUCT SHEET...

This manual is also suitable for:

VariaVelvet