I
NSTALLING THE
Mounting
This switch can be mounted in a standard 19-inch equipment rack or on a
desktop or shelf. Mounting instructions for each type of site follow.
Rack Mounting
Before rack mounting the switch, pay particular attention to the following
factors:
• Temperature: Since the temperature within a rack assembly may be
higher than the ambient room temperature, check that the
rack-environment temperature is within the specified operating
temperature range. (See page C-2.)
• Mechanical Loading: Do not place any equipment on top of a
rack-mounted unit.
• Circuit Overloading: Be sure that the supply circuit to the rack assembly
is not overloaded.
• Grounding: Rack-mounted equipment should be properly grounded.
Particular attention should be given to supply connections other than
direct connections to the mains.
3-4
S
WITCH
Need help?
Do you have a question about the 8708L2 and is the answer not in the manual?
Questions and answers