Installing The Switch; Selecting A Site - SMC Networks 8708L2 Installation Manual

10 gigabit ethernet switch
Hide thumbs Also See for 8708L2:
Table of Contents

Advertisement

I

Selecting a Site

TigerSwitch 10G units can be mounted in a standard 19-inch equipment
rack or on a flat surface. Be sure to follow the guidelines below when
choosing a location.
• The site should:
- be at the center of all the devices you want to link and near a power
outlet.
- be able to maintain its temperature within 0 to 50 °C (32 to 122 °F) and
its humidity within 5% to 95%, non-condensing
- provide adequate space (approximately two inches) on all sides for
proper air flow
- be accessible for installing, cabling and maintaining the devices
- allow the status LEDs to be clearly visible
• Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference,
such as radios and transmitters.
• Make sure that the unit is connected to a separate grounded power outlet
that provides 100 to 240 VAC, 50 to 60 Hz, is within 2 m (6.6 feet) of
each device and is powered from an independent circuit breaker. As with
any equipment, using a filter or surge suppressor is recommended.
NSTALLING THE
C
HAPTER
S
WITCH
3
3-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8708L2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Tigerswitch 10gSmc8708l2

Table of Contents