Page 2
Operation Instructions 1002998-00- / en / 02.2007 AFFINITY 500 SUPER POWER AFFINITY 500 TWIN POWER AFFINITY 600 TWIN POWER AFFINITY 800 TWIN POWER AFFINITY 660 SMART POWER AFFINITY 880 SMART POWER AFFINITY 660 DYNAMIC POWER AFFINITY 880 DYNAMIC POWER AFFINITY 660 DYNAMIC POWER IQ...
Page 3
AFFINITY 500 SUPER POWER AFFINITY 500 TWIN POWER AFFINITY 600 TWIN POWER AFFINITY 800 TWIN POWER AFFINITY 660 SMART POWER AFFINITY 880 SMART POWER AFFINITY 660 DYNAMIC POWER AFFINITY 880 DYNAMIC POWER AFFINITY 660 DYNAMIC POWER IQ AFFINITY 880 DYNAMIC POWER IQ...
Dear Customer, The Ergoline sunbed you have purchased is a technically advanced and • Read and observe the information in this instruction manual. This will high-performance sunbed. Your sunbed was manufactured with the ensure you avoid accidents and have a fully functioning and reliable greatest care and precision.
How to use the instruction manual So that you can quickly find the page you need, chapter titles are shown at the top of each page: at the start of chapter in large text (1) and on subsequent pages, somewhat smaller (2). Symbols are also used.
Meaning of Symbols Hazard instructions Danger! Type and source of hazard! This safety instruction – warning triangle with the word "Danger" – points out primarily that there is a personnel hazard (risk of fatal injury, risk of injury). Example: Danger to life! Electric current! Personnel danger due to electric shock or electric burns.
Page 11
Meaning of Symbols Symbols for Description, Operation and Maintenance Customer service UV high pressure lamps Manufacturer Filter panels Part/article number (for orders) Cleaning and disinfectant agents Danger! Switch the sunbed to a zero-potential state. Tanning Table – isolate from the mains Risk of burning! Operation Do not touch, hot surface...
Page 12
Meaning of Symbols Function can also be used in automatic mode Display: MP3 player connected No cosmetics Display when adjusting the volume Tanning time display Description Display of warm-down time (fan run-on) Decorative lighting Body cooling using Error display (example) AQUA SOLAR WITH SKIN+ ADDITIVE Display Info-Track 1 Fragrance "Relax", "Vital", "Cabin"...
Page 13
Meaning of Symbols Duration: 3 minutes Warning, safety switch! 0-3 min Loudspeaker Unscrew/release screw Headphone connection Tighten/lock screw MP3 player connection Suction cup Default values Clean Technical data Replace Clean or replace depending on the level of Maintenance soiling UV type Test with test strip...
Page 14
Meaning of Symbols Empty Visual inspection Climatronic Filter mat Filter and filter mats must not be damp. Chipcard of lamp set Troubleshooting – see separate manual...
Proper use The sunbed is only intended for commercial use, not for domestic use. This sunbed is for tanning one adult at a time. Infants and small children up to age 7 may not use this sunbed. The following applies for children and adolescents between the ages of 8 and 17 years: Only use sunbeds after agreement with a parent or guardian, or after consulting a doctor.
Safety instructions for the operator • A timer control must be attached so that the sunbed automatically Danger! switches off at the latest after <110% of the selected running time Assembly and electrical connection must comply with the even if the controller fails. The sunbed running time must be provided national regulations.
Safety instructions for the user Danger of skin and eye injuries or skin diseases! • Particular caution is advisable for individuals who are • Persons with very sensitive skin (skin type I) must not use especially sensitive to UV radiation, and when certain the system as, with this skin type, tanning without skin medicaments or cosmetics are used.
Page 18
Safety instructions for the user AFFINITY SUPER POWER, TWIN POWER, SMART POWER, AFFINITY DYNAMIC POWER IQ DYNAMIC POWER Automatic mode • Increasing tanning requires increased exposure time (= In automatic mode, the radiation dose is optimised for the tanning type radiation time) or after a certain degree of tanning has been and the degree to which the skin is already tanned by adjusting the lamp achieved, increased tanning is not possible.
Information for the operator Directives Export This sunbed was built according to the following directives: We emphasise that these sunbeds are intended for the European market and must not be exported to or operated in the USA or Canada! The •...
Audio-CDs, MCs, audio-DVDs etc., on your premises and/ or play music via the ”MP3-music modules" which are provided in the professional sunbeds in the Ergoline range, if you have acquired the necessary stage rights (GEMA/GVL [German copyright handling organisation] Copy-protected audio-CDs, MCs, audio-DVDs etc., as well as titles...
Information for the operator Environmental protection Environmental Declaration – The JK Corporate Group Packaging The JK corporate group is subject to the strict regulations All packaging consists of 100 % recyclable materials. Packaging brought of EC Directive 761/2001 and the standard into circulation by the JK Corporate Group that is no longer required can EN ISO 14001:1996, and undergoes regular internal and be returned to the JK Corporate Group.
Ergoline accepts liability for any sunbed defects that arise in accordance with the following regulations on behalf of customers who have purchased an Ergoline sunbed for private or commercial use from one of Ergoline’s sales partners; consumable parts such as UV-high pressure lamps (bulb), UV-low pressure lamps (tubes) and starters as well as the acrylic-glass base itself are not covered by the guarantee.
Use the sunbed – but use it properly! A few things need to be noted to get maximum enjoyment from a sunbed. sensitivity. If you are in any doubt, first ask your doctor - then you can Here are some answers to frequently asked questions. enjoy the sun at no risk.
Tanning table symbols Tanning table symbols Note: Skin type I (sensitive): The sunbeds (except AFFINITY DYNAMIC POWER IQ) are – Always burns / frequent sunburn. supplied without low pressure lamps. – Accepts only a small amount of natural sun. However, the tanning times are only valid for the lamp set –...
AFFINITY 660 DYNAMIC POWER IQ (maximum mode) Ergoline Dynamic Power 160W (1002022) 04689 / 0 For use in maximum mode only … Max. number of tanning — sessions per year. Note: For the AFFINITY 660/880 DYNAMIC POWER IQ the tanning table is...
AFFINITY 880 DYNAMIC POWER IQ (maximum mode) Ergoline Dynamic Power 160W (1002022) 04689 / 0 For use in maximum mode only … Max. number of tanning — sessions per year. Note: For the AFFINITY 660/880 DYNAMIC POWER IQ the tanning table is...
AFFINITY 660/880 DYNAMIC POWER IQ-Sensor (automatic mode) Ergoline Dynamic Power 160W (1002022) 04689 / 0 Pre-set tanning time! For use in automatic mode only: … Note: For the AFFINITY 660/880 DYNAMIC POWER IQ the tanning table is only valid for maximum mode, not for automatic mode.
Equipment Sunbed equipment varies dependent on the model. In this description, all standard and optional components/functions are taken into account which must be observed during operation and/or when performing maintenance. The control panel is also affected by the differing equipment: Only those buttons are visible that can be operated, i.e.
Description of the AFFINITY series 1. Facial tanner (UV high pressure lamps) 2. Shoulder tanner with audio system loudspeaker (21), headphone connection (2.2), MP3-connection (2.3) 3. Sensor and base station 4. Ultraviolet low pressure lamps, base 5. Partition 6. Acrylic cover, base 7.
Accessories 18. Central air discharge socket 19. Audio-system (with Voice Guide) 20. Shoulder tanner 21. Shoulder tanner with audio-system (with Voice Guide) 22. Mood Light 23. Ambient light (cubicle lighting) 24. Sensor and base station (upgrading only possible with DYNAMIC POWER fitted with audio-system) Some of the accessories are considered in the maintenance plan from page 81 and in the spare parts section from page 133.
However, the tanning time cannot be altered. With Ergoline coin/token operated appliances (studio pilot/studio manager) the minimum tanning time is given by multiplying "minimum exposure" by "time for money".
Maximum mode Start (maximum mode) Danger! Burning is possible! The UV lamps are run at full power in maximum mode. You must abide by the tanning times stipulated in the tanning table – see page 32/33. 07972 / 0 Maximum mode...
Page 46
Maximum mode Close the canopy Start-up adjustments...
Connecting an MP3 player Studio customers may connect their private MP3 players to the sunbed if the ”Audio System” accessory is fitted. Mat.-Nr. 1001855-.. provided for use by the studio operator (1.5 m / 2 x 3.5 mm stereo jack plug). MP3 player connection: refer to the manufacturer’s documentation.
Page 50
Connecting an MP3 player Warning! Heat damage to the MP3 player is possible! – Do not position it directly in the radiation receiving area. Cable may break-off, cable jacks may be damaged! – Do not pull on the cable when unplugging the MP3 player.
Voice Guide Voice guide gives acoustic help information when operating the sunbed and is only available in conjunction with the audio-system (with or without shoulder tanner). Voice Guide is switched on by default when getting ready for operation and during tanning.
Compliance with the specified maintenance intervals and the careful conducting of the maintenance and care work are therefore absolutely High pressure lamps that have not been approved by Ergoline necessary. can explode. Hot lamp components can set other parts on fire.
Safety instructions for maintenance and care Deenergise sunbed and secure against being switched on again A prohibition sign with the text: Danger to life! "Work in progress!" If work is to be performed on the • "Place: ......” sunbeds, they must be deenergised. That means that all live cables must be •...
Safety instructions for maintenance and care Faults Error codes are output to the display to simplify troubleshooting: • If a fault occurs, the error code flashes in the display. • If several faults occur, the fault messages are displayed alternately. •...
Cleaning Acrylic glass surfaces Risk of infections! Warning! Infections can be spread by skin contact. All objects/sunbed parts, which can come into contact with the Do not rub with a dry cloth – danger of scratching! user during tanning, must be disinfected after every tanning For fast, hygienic proper cleaning of acrylic glass surfaces, use session: the specially developed fast disinfectant cleaner Antifect...
Page 83
Cleaning Plastic surfaces Filter and filter mats For cleaning the remaining plastic surfaces, it is best to use warm water Filter in base and a leather cloth. Never use aggressive cleaning agents containing Dry cleaning: Vacuum cleaner (depending on the alcohol, e.g.
Page 84
Cleaning Cleaning filter panels and lamps The UV high-pressure lamps used are broadband radiators that can be operated with different wattages (approx. 240-520 W). UV low pressure lamps: Clean with clear water (moist cloth) UV high pressure lamps: Glass flask with industrial alcohol if required.
Maintenance AQUA FRESH Acrylic covers The AQUA FRESH function sprays a fine mist of AQUA SOLAR WITH The acrylic covers for the sunbedss are produced of acrylic glass SKIN ADDITIVE into the tanning chamber. developed especially for this application. The acrylics used are characterised by a particularly high UV permeability and resistance, as Customer health hazard! well as an easy-care, hygienic surface that is gentle to the skin.
Cleaning and maintenance intervals After each tanning Adjustable air nozzles MP3 cable Cleaning must be confirmed by pressing the START/STOP button (if the warm-down time of the main fan has finished). Intervals Intervals, see ”Product information ...
Page 87
Cleaning and maintenance intervals – Empty 50 h ...
Page 88
Cleaning and maintenance intervals 30 days The sensor must be recalibrated every 30 working days, so that the user’s tanning type can be determined reliably and thee lamp output matched to the tanning type. Calibration: see separate guide “Calibration” (Order no.: 842952-..) 300 h...
Page 89
Cleaning and maintenance intervals 500 h 104, 1000 h 94, 96, b) - e) 98, 100 102, f) g) h) 110,...
Page 90
Cleaning and maintenance intervals 1500 h 3000 h 104,...
Page 91
Cleaning and maintenance intervals 40000 h ...
Sensor and base station cleaning (DYNAMIC POWER IQ) Disinfect sensor and base station after each use with Antifect ® Warning! Do not spray or immerse! Wipe only with a soft and slightly damp cloth! Warning! Do not rub with a dry cloth – danger of scratching! For cleaning of sensor and base station use only the specially...
Cleaning/replacing decorative lighting in the canopy 09697 / 0 03350 / 0 Warning! Paint damage is possible! When screwing maintain a distance from the bottom edge.
Page 112
Cleaning/replacing decorative lighting in the canopy 03099 / 0 09698 / 0...
AQUA FRESH system: Replacing the canister 03388 / 2 03353 / 2...
Page 127
AQUA FRESH system: Replacing the canister 04102 / 1 Note: After replacing the canister, the system must be vented. To do this change to service mode and select function 18 (see page 78). 04101 / 1...
Connected load, power and installation location AFFINITY 500 AFFINITY 500 AFFINITY 600 AFFINITY 800 AFFINITY 660 Sunbed type: SUPER POWER TWIN POWER TWIN POWER TWIN POWER SMART POWER Rated 7800 W 10300 W 10800 W 12700 W 12900 W powerconsumption: Rated voltage: 400-415V ~3N Rated frequency:...
Page 129
Connected load, power and installation location AFFINITY 880 AFFINITY 660 AFFINITY 880 AFFINITY 660 AFFINITY 880 Sunbed type: SMART POWER DYNAMIC POWER DYNAMIC POWER DYN. POWER IQ DYN. POWER IQ Rated 14400 W 17500 W 18500 W 17500 W 18500 W powerconsumption: Rated voltage: 400-415V ~3N...
Page 132
JK-Global Service GmbH ● Lamp configuration JK-Licht GmbH ▲ Decorative lighting (all models) Standard lamps blue 36 W 11792-.. ▲ blue 58 W 12063-.. ▲ blue 30 W 12377-.. ▲ Starter f) g) h) 10047-.. ▲...
Page 133
JK-Global Service GmbH ● Lamp configuration JK-Licht GmbH ▲ Decorative lighting (accessories) Ambient Light (cubicle lighting ) blue 36 W 11797-.. ▲ white 36 W 1002113-.. ▲ Makrolon tube red 1500716-.. ▲ with or yellow 1500708-.. ▲ or magenta 1500710-.. ▲...
Dimensions 03411 / 1 09569 / 0 AFFINITY AFFINITY 500/600/660 800/880 1,740 mm 1,795 mm 1,340 mm 1,360 mm 1,420 mm 1,520 mm 2,000 mm 2,000 mm E1 = 2,260 mm 2,260 mm E2 = 2,350 mm 2,350 mm 800 mm 900 mm TK = 2,300 mm...
Page 139
Index Interior lighting, maintenance....102 Plastic surfaces (care)......... 82 Stage rights ..........19 Interrupting / terminating a tanning session 46 Plug connection........... 15 Starter............129 Itching (pruritus).......... 16 Power ............127 Starting tanning ...........40 Product information ........18 Start-up adjustments ........40 Proper use........... 14 Sunbed description........36 Lamp configuration ........
Page 140
. Köhlershohner Straße . 53578 Windhagen . GERMANY J K- S A L E S G M B H Internet: www.ergoline.de · E-Mail: info@ergoline.de Phone: +49 (0) 2224/818-0 . Fax: + 49 (0) 2224/818-116...
Need help?
Do you have a question about the AFFINITY 500 SUPER POWER and is the answer not in the manual?
Questions and answers