Download Print this page

ADF Web HD67571-A1 User Manual

Canopen / profibus master - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.010
English
CANopen / PROFIBUS Master - Converter
(Order Code: HD67571-A1)
for Website information:
http://www.adfweb.com/?Product=HD67571
for Price information:
http://www.adfweb.com/?Price=HD67571-A1
Benefits and Main Features:
Very easy to configure
Low cost
Industrial temperature range:
-40°C / +85°C (-40°F / +185°F)
ADFweb.com Srl – IT31010 – Mareno – Treviso
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
User Manual CANopen / PROFIBUS Master
Document code: MN67571_ENG
For others PROFIBUS devices, see also the following links:
PROFIBUS Slave from/to ...
www.adfweb.com?Product=HD67045
www.adfweb.com?Product=HD67053
www.adfweb.com?Product=HD67551
www.adfweb.com?Product=HD67552
www.adfweb.com?Product=HD67553
www.adfweb.com?Product=HD67554
www.adfweb.com?Product=HD67555
www.adfweb.com?Product=HD67561
www.adfweb.com?Product=HD67562
www.adfweb.com?Product=HD67563
www.adfweb.com?Product=HD67564
www.adfweb.com?Product=HD67565
PROFIBUS Master from/to ...
www.adfweb.com?Product=HD67570
www.adfweb.com?Product=HD67575
www.adfweb.com?Product=HD67579
www.adfweb.com?Product=HD67580
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Phone +39.0438.30.91.31
in India
in India
in India
in India
Revision 1.010
Page 1 of 38
(... Serial)
(... M-Bus Master)
(... CANopen)
(... CAN)
(... J1939)
(... DeviceNet Slave)
(... DeviceNet Master)
(... Modbus Master)
(... Modbus Slave)
(... Ethernet Server)
(... Modbus TCP Client)
(... Modbus TCP Server)
(... DeviceNet Slave)
(... Ethernet)
(... Modbus TCP Slave)
(... Modbus Slave)

Advertisement

loading
Need help?

Need help?

Do you have a question about the HD67571-A1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web HD67571-A1

  • Page 1 Page 1 of 38 Industrial Electronic Devices User Manual Revision 1.010 English CANopen / PROFIBUS Master - Converter (Order Code: HD67571-A1) for Website information: http://www.adfweb.com/?Product=HD67571 For others PROFIBUS devices, see also the following links: for Price information: http://www.adfweb.com/?Price=HD67571-A1 PROFIBUS Slave from/to …...
  • Page 2: Table Of Contents

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 2 of 38 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX Updated;...
  • Page 3: Security Alert

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 3 of 38 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for each individual application, legal and safety regulation.
  • Page 4: Example Of Connection

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 4 of 38 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 5 of 38 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67571-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6: Characteristics

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 6 of 38 Industrial Electronic Devices CHARACTERISTICS: The configurable “CANopen / PROFIBUS Master - Converter” allows the following characteristics: Triple isolation between CANopen/PROFIBUS, CANopen/Power Supply, PROFIBUS/Power Supply. Mountable on 35mm Rail DIN; Power Supply 8...24V AC or 12...35V DC;...
  • Page 7: Power Supply

    POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin Vmax HD67571-A1 Consumption at 24V DC: Device W/VA HD67571-A1 Caution: Not reverse the polarity power HD67571-A1 ADFweb.com Srl –...
  • Page 8: Function Modes

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 8 of 38 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip2 of ‘Dip-Switch A’: The first, with Dip2 in Off position (factory setting), is used for the normal working of the device. The second, with Dip2 in On position, is used for upload the Project/Firmware.
  • Page 9: Leds

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 9 of 38 Industrial Electronic Devices LEDS: The device has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Powered...
  • Page 10: Profibus

    ETHERNET: The Ethernet connection must be made using Connector3 of HD67571-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC/PLC/other is recommended the use of a cross cable.
  • Page 11: Canopen

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 11 of 38 Industrial Electronic Devices CANOPEN: For terminate the CANopen line with a 120Ω resistor it is necessary that the Dip1 of ‘Dip-Switch B’ is at ON position. Cable characteristics: DC parameter: Impedance...
  • Page 12: Use Of Compositor Sw67571

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 12 of 38 Industrial Electronic Devices USE OF COMPOSITOR SW67571: To configure the Gateway, use the available software that runs with Windows, called SW67571. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 13: Software Options

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 13 of 38 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “ ” button from the main window for SW67571 (Fig. 2), the window “Software Options” (Fig. 3) appears. By pressing the “Language”...
  • Page 14: New Configuration / Open Configuration

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 14 of 38 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Project” button creates the folder which contains the entire device configuration. A device configuration can also be imported or exported: To clone the configurations of a Programmable “CANopen / PROFIBUS Master - Converter”...
  • Page 15: Set Communication

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 15 of 38 Industrial Electronic Devices SET COMMUNICATION: This section defines the fundamental communication parameter of two buses, PROFIBUS and CANopen. By pressing the “Set Communication” button from the main window for SW67571 (Fig. 2) the window “Set Communication”...
  • Page 16: Ping Device

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 16 of 38 Industrial Electronic Devices PING DEVICE: By pressing the “Ping Device” button from the main window for SW67571 (Fig. 2) the window “Test Ping” (Fig. 7) appears. Figure 7: “Test Ping”...
  • Page 17: Profibus Network

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 17 of 38 Industrial Electronic Devices PROFIBUS NETWORK: By pressing the “PROFIBUS Network” button from the main window for SW67571 (Fig. 2) the window “PROFIBUS Network” (Fig. 8) appears.
  • Page 18: Master Profibus Options

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 18 of 38 Industrial Electronic Devices MASTER PROFIBUS OPTIONS: By pressing the “Master PROFIBUS Options” button from the “PROFIBUS Network” window (Fig. 8) the “PROFIBUS Master Options” window appears (Fig. 9). In this window is possible to set the WatchDog Time for the PROFIBUS Slaves.
  • Page 19: Profibus Device

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 19 of 38 Industrial Electronic Devices PROFIBUS DEVICE: By pressing the “Add Slave PROFIBUS” and “Modify Slave PROFIBUS” button (or double click above an existent PROFIBUS Slave) from “PROFIBUS Network”...
  • Page 20: Module Selection

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 20 of 38 Industrial Electronic Devices ODULE ELECTION The section “Module Selection” is used to select which Modules are present in the Slave (Fig. 11). In this section is possible to: Check the list of the Modules selected (“Select Modules”) (Fig.
  • Page 21 User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 21 of 38 Industrial Electronic Devices By pressing the “Manual Module” button from the “PROFIBUS Device” window (Fig. 11) the “Add Module Manually” window appears (Fig. 12). In this window is possible to add a Module manually, i.e. writing the configuration of the module (in hexadecimal). The means of the fields are: In the field “Description of...
  • Page 22: User Parameters

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 22 of 38 Industrial Electronic Devices ARAMETERS The section “User Parameters” is used to modify the parameters of the PROFIBUS slave (Fig. 13). In this section there are: The List of all Parameters available for...
  • Page 23 User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 23 of 38 Industrial Electronic Devices By pressing the “Modify User Parameters Manually” button from the “PROFIBUS Device” window (Fig. 13) the “Add Module Manually” window appears (Fig. 14). In this window is possible to add/modify the User and/or Modules Parameters manually, i.e.
  • Page 24: Module Parameters

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 24 of 38 Industrial Electronic Devices ODULE ARAMETERS The section “Module Parameters” is used to modify the parameters of the Modules (Fig. 15). In this section there are: The List of all Module selected in the GSD file (“Available modules”) (Fig.
  • Page 25 User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 25 of 38 Industrial Electronic Devices APABILITIES The section “Capabilities” is used only to show which features/baudrates available in the PROFIBUS device. The Green Icon indicate that capability/baudrate is available, the Red Icon indicate no compatibilities with that capability/baudrate (Fig. 16). Figure 16: “PROFIBUS Device –...
  • Page 26 User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 26 of 38 Industrial Electronic Devices PTIONS The section “Options” is used to enable some option for each PROFIBUS device (Fig. 17). The means of the fields are: field “Enable Sync”...
  • Page 27: Set Sdo Server

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 27 of 38 Industrial Electronic Devices SET SDO SERVER: By pressing the “Set SDO Server” button from the main window for SW67571 (Fig. 8) the window “Set SDO Server Access” appears (Fig. 18).
  • Page 28: Set Sdo Client

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 28 of 38 Industrial Electronic Devices SET SDO CLIENT: By pressing the “Set SDO Client” button from the main window for SW67571 (Fig. 8) the window “Set SDO Client Access” appears (Fig. 19a and 19b).
  • Page 29 User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 29 of 38 Industrial Electronic Devices In the field “Mnemonic” the description for the SDO is defined. It is possible to configure a maximum of 256 read SDOs in the “Set SDO Client Access – SDO Read” section. The data of the columns in the “SDO Write”...
  • Page 30: Set Pdo Access

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 30 of 38 Industrial Electronic Devices SET PDO ACCESS: By pressing the “Set PDO Access” button from the main window for SW67571 (Fig. 8) the window “Set PDO Access” appears (Fig. 20a and 20b).
  • Page 31 User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 31 of 38 Industrial Electronic Devices The field “TimeOut” is used for put at zero the data into PROFIBUS if the PDO doesn’t arrive with a frequency less than the time expressed in the field.
  • Page 32 User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 32 of 38 Industrial Electronic Devices data columns “Transmit PDO” have the following meanings: Field "Cob-ID" address for the PDO is defined; In the Field "Dimension" the dimension of the PDO is defined (it can be between 1 and 8);...
  • Page 33: Update Device

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 33 of 38 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button it is possible to load the created Configuration into the device; and also the Firmware, if is necessary. If you don’t know the actual IP address of the device you have to use this procedure: Turn off the Device;...
  • Page 34 At this point the configuration/firmware on the device is correctly update. Note: When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67571-A1 device. Warning: If the Fig.
  • Page 35: Mechanical Dimensions

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 35 of 38 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 23: Mechanical dimensions scheme ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 36: Ordering Informations

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 36 of 38 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD67571 – A 1 Connectors Type 1: Removable 5mm Screw Terminal Enclosure Type A: 1M, 35mm DIN Rail mounting Device Family...
  • Page 37: Disclaimer

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 37 of 38 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice. The content of the document content is a recurring audit. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 38: Warranties And Technical Support

    User Manual CANopen / PROFIBUS Master Document code: MN67571_ENG Revision 1.010 Page 38 of 38 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: 1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.