ADF Web HD67159-A1 User Manual

Snmp agent / ethernet/ip slave -converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
SNMP Agent / EtherNet/IP Slave -
Converter
(Order Code: HD67159-A1)
for Website information:
http://www.adfweb.com/?Product=HD67159
for Price information:
http://www.adfweb.com/?Price=HD67159-A1
Benefits and Main Features:
Triple electrical isolation
Two Ethernet ports
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual SNMP Agent / EtherNet/IP Slave
Document code: MN67159_ENG
For others SNMP Agent devices, see also the following links:
Converter SNMP to
www.adfweb.com?Product=HD67040
www.adfweb.com?Product=HD67092
www.adfweb.com?Product=HD67155
www.adfweb.com?Product=HD67156
www.adfweb.com?Product=HD67158
www.adfweb.com?Product=HD67160
www.adfweb.com?Product=HD67161
www.adfweb.com?Product=HD67162
www.adfweb.com?Product=HD67163
www.adfweb.com?Product=HD67164
www.adfweb.com?Product=HD67165
www.adfweb.com?Product=HD67166
www.adfweb.com?Product=HD67167
www.adfweb.com?Product=HD67168
www.adfweb.com?Product=HD67169
www.adfweb.com?Product=HD67613
www.adfweb.com?Product=HD67626
www.adfweb.com?Product=HD67693
www.adfweb.com?Product=HD67726
www.adfweb.com?Product=HD67753
www.adfweb.com?Product=HD67779
www.adfweb.com?Product=HD67820
www.adfweb.com?Product=HD67850
www.adfweb.com?Product=HD67878
www.adfweb.com?Product=HD67913
www.adfweb.com?Product=HD67954
www.adfweb.com?Product=HD67987
www.adfweb.com?Product=HD67B23
www.adfweb.com?Product=HD67B48
www.adfweb.com?Product=HD67B77
www.adfweb.com?Product=HD67C79
www.adfweb.com?Product=HD67D41
www.adfweb.com?Product=HD67E25
www.adfweb.com?Product=HD67E75
www.adfweb.com?Product=HD67F41
INFO:
www.adfweb.com
Revision 1.000
Page 1 of 27
(DMX)
(M-Bus Wireless)
(CAN)
(CANopen)
(EtherNet/IP Master)
(DeviceNet Master)
(DeviceNet Slave)
(J1939)
(M-Bus Master)
(Modbus Master)
(Modbus Slave)
(Modbus TCP Master)
(Modbus TCP Slave)
(PROFIBUS Master)
(PROFIBUS Slave)
(PROFINET Slave)
(S7comm)
(BACnet Slave)
(BACnet Master)
(IEC 61850 Server)
(IEC 61850 Client)
(KNX)
(DALI)
(IO-Link Master)
(HART)
(MQTT)
(IO-Link Slave)
(OPC UA Client)
(OPC UA Server)
(PROFINET Master)
(EnOcean)
(LoRaWAN)
(EtherCAT Slave)
(EtherCAT Master)
(LoRaWAN Gateway)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67159-A1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67159-A1

  • Page 1 For others SNMP Agent devices, see also the following links: Converter SNMP to SNMP Agent / EtherNet/IP Slave - www.adfweb.com?Product=HD67040 (DMX) www.adfweb.com?Product=HD67092 (M-Bus Wireless) Converter www.adfweb.com?Product=HD67155 (CAN) (Order Code: HD67159-A1) www.adfweb.com?Product=HD67156 (CANopen) www.adfweb.com?Product=HD67158 (EtherNet/IP Master) www.adfweb.com?Product=HD67160 (DeviceNet Master) for Website information: www.adfweb.com?Product=HD67161 (DeviceNet Slave) http://www.adfweb.com/?Product=HD67159...
  • Page 2: Table Of Contents

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 2 of 27 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 3 of 27 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 4 of 27 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 5 of 27 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67159-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6: Characteristics

    Page 6 of 27 Industrial Electronic Devices CHARACTERISTICS: The HD67159-A1 is a SNMP Agent / EtherNet/IP Slave converter. It allows the following characteristics: Up to 496 bytes in reading and 496 bytes in writing; Two-directional information between EtherNet/IP and SNMP;...
  • Page 7: Power Supply

    POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin Vmax HD67159-A1 Consumption at 24V DC: Device W/VA HD67159-A1 Caution: Not reverse the polarity power HD67159-A1 ADFweb.com Srl –...
  • Page 8: Function Modes

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 8 of 27 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’: The first, with Dip1 in Off position (factory setting), is used for the normal working of the device. The second, with Dip1 in On position, is used for upload the Project/Firmware.
  • Page 9: Leds

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 9 of 27 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 10: Ethernet

    ETHERNET: The Ethernet connection must be made using Connector3 or Connector4 of HD67159-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC/PLC/other is recommended the use of a cross cable.
  • Page 11: Use Of Compositor Sw67159

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 11 of 27 Industrial Electronic Devices USE OF COMPOSITOR SW67159: To configure the Converter, use the available software that runs with Windows called SW67159. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 12: New Project / Open Project

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 12 of 27 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “SNMP Agent / EtherNet/IP Slave - Converter”...
  • Page 13: Software Options

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 13 of 27 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor. In the section “Language”...
  • Page 14: Set Communication

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 14 of 27 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, SNMP and EtherNet/IP. By Pressing the “Set Communication” button from the main window for SW67159 (Fig. 2) the window “Set Communication”...
  • Page 15: Set Snmp Access

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 15 of 27 Industrial Electronic Devices SET SNMP ACCESS: By pressing the “Set SNMP Access” button from the main window for SW67159 (Fig. 2) the “Set SNMP Access” window appears (Fig. 4). In this section, it is possible to create the OIDs for SNMP side to read or write using GET and SET commands or to be sent as TRAP messages.
  • Page 16 User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 16 of 27 Industrial Electronic Devices The data of the columns in “SNMP Write” have the following meanings: If the field “Enable” is checked, SNMP OID is enabled; field “Community Name”...
  • Page 17: Snmp Mib

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 17 of 27 Industrial Electronic Devices SNMP MIB: By pressing the “SNMP MIB” button it is possible to save the MIB file for the SNMP Manager. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 18: Update Device

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 18 of 27 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port. If you don’t know the actual IP address of the device you have to use this procedure: Turn OFF the Device;...
  • Page 19 User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 19 of 27 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67159 device. Warning: If Fig.
  • Page 20: Plc Configuration

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 20 of 27 Industrial Electronic Devices PLC CONFIGURATION: The configuration and commissioning of the EtherNet/IP Converter as described on the following pages was accomplished with the help of the “RSLogix 5000”...
  • Page 21 User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 21 of 27 Industrial Electronic Devices 2) Edit the settings of the new Generic Ethernet Module. As shown in the screen shot below, the module was named “HD67159” and the IP-address assigned is 192.168.0.5. For the Comm Format “Data –...
  • Page 22 User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 22 of 27 Industrial Electronic Devices 4) After the configuration is completed, the controller tags are created. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 23 User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 23 of 27 Industrial Electronic Devices 5) With “RSLinks Classic Lite”, after have done a network scan (RSWho), and finding the EtherNet/IP device, it is possible to load the EDS file for the device in order to have the “Module Info”...
  • Page 24: Mechanical Dimensions

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 24 of 27 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 7: Mechanical dimensions scheme for HD67159-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 25: Ordering Informations

    Enclosure Type A: 1M, 35mm DIN Rail mounting Device Family HD67159: SNMP Agent / EtherNet/IP Slave - Converter Order Code: HD67159-A1 SNMP Agent / EtherNet/IP Slave - Converter ACCESSORIES: Order Code: AC34011 Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC Order Code: AC34012 Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 26: Disclaimer

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 26 of 27 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 27: Warranties And Technical Support

    User Manual SNMP Agent / EtherNet/IP Slave Document code: MN67159_ENG Revision 1.000 Page 27 of 27 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents