Troubleshooting - Harbor Breeze CHW52WW3LR Manual

Chetwood led ceiling fan
Table of Contents

Advertisement

TROUBLESHOOTING

WARNING: Before beginning work, shut off the power supply to avoid electrical shock.
PROBLEM
Fan does not
move.
Noisy operation.
Excessive
wobbling.
Fan operates but
light fails
Remote control fails
to operate.
NOTE: A small amount of "wobble" is normal and should not be considered a defect.
POSSIBLE CAUSE
1. Power is off or fuse is blown.
2. Faulty wire connection.
3. Learning code process between fan
and remote control transmitter may
not have been successful and learning
code was not activated.
4. Blades are not installed.
1. Blades are loose.
2. Cracked blade.
3. Full range dimmer switch.
4. Fan is new.
1. Blades are loose.
2. Blades incorrectly attached.
3. Unbalanced blades.
4. Fan not securely mounted.
5. Fan too close to vaulted ceiling.
6. Set screw(s) on motor housing yoke is
(are) not tightened properly.
7. Set screw on hanging ball is not
tightened properly.
1. Wires in canopy not wired properly.
2. Wall switch to fan is off.
3. Wires from LED light kit not wired
correctly.
1. Remote control transmitter not synced
with fan.
2. Batteries not installed correctly.
3. Battery/Batteries no longer working.
CORRECTIVE ACTION
1. Turn power on or check fuse.
2. Turn power off. Loosen canopy and
check all connections.
3. Turn off power and repeat
instructions in Step 2 on page 16.
4. Install all blades (see page 13).
1. Tighten all blade screws.
2. Replace blade.
3. Replace with an approved speed
control device.
4. Allow fan a "break in" period of a few
days, especially when running the
fan at Medium and High speeds.
1. Tighten all blade screws.
2. Re-install blades.
3. Switch one blade with a blade from
the opposite side.
4. Turn power off. Carefully loosen
canopy and verify that mounting
bracket is secure.
5. Use a longer downrod or move fan to
another location.
6. Tighten yoke set screw(s) securely.
7. Carefully loosen and lower canopy
and verify that set screw on hanging
ball is tightened securely.
1. Check wires in canopy and, if
necessary, re-wire according to
instructions on page 11.
2. Make sure that wall switch to fan is
on.
3. Check wires from LED light kit and,
if necessary, re-wire according to
instructions on page 14.
1. Refer to instructions in Step 2 on
page 16.
2. Check that batteries have been
installed with correct polarity.
3. Replace both batteries according
to instructions on page 16.
18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHW52WW3LR and is the answer not in the manual?

This manual is also suitable for:

Chw52mbk3lr62458756245877

Table of Contents