Page 5
Table of contents Configuration..........34 10.1 Display on the device .
Page 6
About this documentation 1 About this documentation Validity This manual is valid for all devices with an SPE interface (Single Pair Ethernet). Purpose This documentation is part of the device and includes all information to ensure that it is used safely and as intended across all phases of the product lifecycle.
Page 7
1 About this documentation PoDL Power over Data Line (power is supplied in parallel to data transmission via the single-pair Ethernet connection) Relative pressure SCCP Serial Communication Classification Protocol (automatic negotiation of the PoDL class) Single Pair Ethernet Programmable Logic Controller Transmission Control Protocol (standard for network conversation) UKCA UK Conformity Assessed...
Page 8
Safety 2 Safety Intended use The device is intended for measuring relative and absolute pressures of gases, steam, and liquids. The device's pressure range needs to be taken into account here. In order to ensure the device's perfect condition, only media may be used to which the materials in con- tact with the media are sufficiently resistant.
Page 9
Declarations of conformity Radio Equipment Directive (RED) JUMO GmbH & Co. KG hereby states that the device complies with the Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available on the manufacturer‘s website. Federal Communications Commission (FCC) This device complies with part 15 of the FCC rules.
Page 10
Description 3 Description Structure Display M12 connector Pressure compensation element (only with "relative pressure" version) Housing for electronic components Process connection Function The process pressure has an effect on the piezoresistive sensor element via the metallic pressure mea- surement membrane. Deformation of the membrane and the sensor element occurs due to the applica- tion of force;...
Page 11
3 Description Nameplate Manufacturer and address DELOS S02 Device designation Device version Part no. Measuring range Voltage supply Output F-Nr. Fabrication number The production date (year/week) can be taken from the serial number. These are the characters 12, 13, 14, 15.
Page 12
VARIVENT® type N DN 50/40 with EPDM O-ring Process connection 710 Aseptic DN 25 DIN 11864-3-A Process connection 711 Aseptic DN/OD 33.7 DIN 11864-3-A Process connection 997 JUMO PEKA with FKM O-ring Scope of delivery Device in the ordered version Quick start guide...
Page 13
Technical data 4 Technical data Electrical safety Requirements DIN EN 61010-1:2020 The device must be equipped with an electrical circuit that meets the require- ments for "Limited-energy circuits". Electrical data Voltage supply DC 18 to 30 V, PELV Current consumption ≤...
Page 14
4 Technical data Inputs 4.3.1 Measuring range and accuracy Relative pressure Nominal measuring range Linearity Accuracy at Long-term Overload Burst stability capability pressure 20 °C -20 to +75 °C % MSP % MSP % MSP % MSP per year 0 to 0.4 0.15 0.40 1.00...
Page 15
4 Technical data Interfaces 4.4.1 Bluetooth Function Transfer of configuration data and device information, display of process val- Communication Via mobile end device with the JUMO smartCONNECT app Authentication Via NFC Connection status (configurable) Active Inactive Restricted (via NFC) Range...
Page 16
4 Technical data Environmental influences Admissible medium temperature -25 to +100 °C (135 °C maximum 1 hour per day; no function here) Admissible ambient temperature -25 to +75 °C Admissible storage temperature -40 to +85 °C Climatic conditions DIN EN 60721-3-3 Climate class Storage Relative humidity ≤...
Page 17
4 Technical data Dimensions 4.8.1 Device 4.8.2 Process connections Process connections, not front-flush G 1/2 DIN EN 837 (Order code 504) • Wrench size SW27 • Tightening torque: 30 Nm 17,5 G 1/2 1/4“ – 18 NPT DIN EN 837 (Order code 511) •...
Page 18
4 Technical data G 1/4 DIN EN 3852-11 (Order code 521) (A) Sealing ring G 1/4 • Wrench size SW27 G 1/4 • Tightening torque: 20 Nm G 1/2 DIN EN 3852-11 (Order code 523) (A) Sealing ring G 1/2 •...
Page 19
4 Technical data G 1/2 front-flush with double seal (Order code 574) (A) Sealing ring G 1/2 (B) O-ring 15.1 × 1.78 • Wrench size SW27 G 1/2 • Tightening torque: 25 Nm Operating condition: = 25 bar → -10 °C < T < +150 °C = 40 bar →...
Page 20
4 Technical data Taper socket with union nut DN 40 DIN 11851 (Order code 606) (A) Grooved union nut DN 40 Operating condition: = 40 bar → -10 °C < T < +140 °C Clamping socket (clamp) DN 10, DN 15, DN 20 DIN 32676 (Order code 612) Operating condition:...
Page 21
4 Technical data JUMO PEKA Hygienic process connection (Order code 997) (A) O-ring 26 × 2.5 (B) O-ring 21 × 2.5 (not included in the scope of delivery) M28 × 1,5 • Wrench size SW27 • Tightening torque: 20 Nm...
Page 22
Installation 5 Installation NOTE! Ensure the compatibility of the device and measurement medium before installation. Preparing for installation 5.1.1 Installation site The device is protected from UV radiation. The device is protected from the weather when used outside. admissible environmental influences must observed...
Page 23
5 Installation Device Shut-off valve Pipe Steam Use a siphon for pressure measurement in steam. The device is protected against excessive tempera- tures thanks to the condensate in the pipe bend. The device can be mounted above or below the measuring point. Installation below is recommended. Device Shut-off valve Pipe...
Page 24
Clamp connections DN 25, DN 32, DN 40, DN 50, DN 100 or 1“, 1 1/2“, 2 1/2“, 4“ with Tri-Clamp seal Combifit International B.V. • JUMO PEKA with FKM O-ring • VARINLINE® housing with process connection type N or type G with EPDM O-ring •...
Page 25
5 Installation The following drawing shows an installation example. Observe dimensions to avoid cavity: L < D. Leakage opening Rear seal Front-flush seal Installing the device NOTE! The pressure measurement membrane is located in the process connection and is very sensitive. Irrep- arable damage may occur due to sharp or hard objects.
Page 26
Electrical connection 6 Electrical connection Terminal assignment 6.1.1 Terminal assignment, M12 connector, SPE Device M12 connecting cable Terminal assignment and color coding RxTx+/PoDL+ (1) – WH (white) RxTx-/PoDL- (2) – BU (blue) Connection type Plug connector M12 according to IEC Plug connector M12 with screw lock- 63171-5 Connecting the device...
Page 27
7 Startup Startup Zero point adjustment An automatic pressure zero point adjustment can be performed. A zero offset depending on position can therefore be corrected, for example. The current measured value is adopted as a negative offset if the zero point adjustment is performed. Procedure: The zero point adjustment can be performed via Modbus TCP or the app.
Page 28
Operation 8 Operation Device info display As soon as the device is supplied with voltage, a device info display appears on the display. The device info display includes information on the software version. The display is shown depending on the configured display orientation. After 3 seconds, the device info display switches to the basic status.
Page 29
8 Operation 8.2.3 Text line Unit If there is an error, the unit configured for the display is shown in the text line. Error message Error messages and warnings are specified as running text in the text line. 8.2.4 Toolbar Bluetooth connection status Bluetooth connection status Symbol...
Page 30
9 Interfaces Interfaces Bluetooth The device can be operated and configured via the JUMO smartCONNECT app. The connection is es- tablished via Bluetooth. Authentication takes place via NFC. 9.1.1 App download The "JUMO smartCONNECT" app is available as a free download for Android smartphones (via Google Play) and Apple smartphones (via App Store).
Page 31
Inactive The Bluetooth connection can also be configured as permanently "inactive". This setting is not available in the app. Bluetooth can be deactivated via Modbus TCP. 9.1.5 JUMO smartCONNECT app Start screen • The current connection status is displayed. •...
Page 32
Connection between smartphone and device is terminated JUMO Cloud The device can be connected to the JUMO Cloud or any instance of the audako Cloud. Values can be read out and the device configured via the cloud. However, not all parameters are available.
Page 33
Address The Smart Device Wizard in the cloud simplifies startup. 9.2.3 Further information A detailed description of the JUMO Cloud can be found in the help center. Modbus TCP The device can be accessed via Modbus TCP using a tool or directly via PLC.
Page 34
10 Configuration Configuration The device has several interfaces and thus several operating options. The configuration parameters are mostly identical. Since the menu structure differs depending on the interface, the configuration parame- ters are listed sorted by function. 10.1 Display on the device Parameter Value Default setting...
Page 35
Inactive – cloud Inactive Cloud server JUMO Cloud JUMO Cloud JUMO Cloud: The JUMO Cloud is used. Individual Individual: The cloud server is determined by an individ- ual URL. Server URL (de- – – Only if "Cloud Server" = "individual"...
Page 36
10 Configuration 10.3 Pressure measurand Parameter Value Default setting Description Offset -999 bar to 0 bar Offset correction to eliminate detected deviation. +999 bar Measuring range monitoring occurs before the offset is added to the measured value. Filter time con- 0 s to 99.99 s The process value can be attenuated by a 2nd order filter.
Page 37
10 Configuration Different switching modes are selectable, all of which can be inverted. In addition, the limit value switches have a switching delay. Switching delay A switching delay for switching on and / or switching off can be configured. If the switching condition is fulfilled, the set timer for the switch-on delay (Δ ) starts to elapse.
Page 38
10 Configuration Hysteresis mode If the process value exceeds the switching point SP1, the output of the limit value switch becomes active. If the switching point SP1 reduced by the amount of the hysteresis is undershot again, the output of the limit value switch becomes inactive again.
Page 39
10 Configuration Window mode Window mode checks whether the process value is within a certain range. SP is defined as the smaller value of switching points SP1 and SP2. SP is defined as the larger value of switching point SP1 and SP2.
Page 40
10 Configuration Two-point mode In two-point mode, two switching points are defined. If the process value exceeds the SP switching point, the limit value switch output becomes active. If the process value falls below the SP switching inact point, the output becomes inactive. is defined as the larger value of switching points SP1 and SP2, SP is correspondingly the inact...
Page 41
Modbus address tables 11 Modbus address tables 11.1 Transmission All data types are transmitted in big-endian format according to Modbus standard. 11.2 Version and fabrication number Modbus PDU Data type Number of Data Encoding address Modbus cess registers 0x0015 string Software version number –...
Page 42
11 Modbus address tables Analog input Modbus PDU Data type Number of Data Encoding address Modbus cess registers 1200 0x04B0 float Offset -999 to +999 1202 0x04B2 float Filter time constant 0 s to 100 s r/w: Read and write access Modbus TCP The following settings of the units concern the Modbus interface.
Page 43
11 Modbus address tables Limit value function Modbus PDU Data type Number of Data Encoding address Modbus cess registers 2350 0x092E float LVS 1: Switching point SP1 -1 bar to +100 bar 2352 0x0930 float LVS 1: Switching point SP2 -1 bar to +100 bar 2354 0x0932 selection LVS 1: Inversion...
Page 44
11 Modbus address tables 11.4 Actions Modbus PDU Data type Number of Data Encoding address Modbus cess registers 3000 0x0BB8 action Save configuration Save (0xC7E7BC2E) Discard (0xF0864181) Default setting (0x34BFE138) 3627 0x0E2B action Teach function Teach SP1 (0x57FBE8) Teach SP2 (0x35800A1) 3650 0x0E42 action Zero point adjustment...
Page 45
11 Modbus address tables Limit value monitoring function Modbus PDU Data type Number of Data Encoding address Modbus cess registers 3625 0x0E29 unsigned Measuring channel for 1: Measuring channel 1 (limit short inte- which teach process is to value switch 1) be executed 2: Measuring channel 1 (limit value switch 2)
Page 46
Troubleshooting 12 Troubleshooting 12.1 Process value error Process value errors are displayed instead of the process value. In part, process value errors are sup- plemented with error messages in the text line. Error message Cause Remedy ---- The input value is invalid. The sensor is Contact the manufacturer.
Page 47
12 Troubleshooting green flashing Maintenance required Error message Cause Remedy Restart the device The device must be restarted due to a con- Restart the device. figuration change. yellow continuously lit Outside the specification (S) Error message Cause Remedy Device operating condi- The device is operated outside the device Operate the device within the device speci- tions...
Page 48
Maintenance and cleaning 13 Maintenance and cleaning 13.1 Maintenance The device is maintenance-free. 13.2 Cleaning 13.2.1 Cleaning device housing Clean the device from the outside with a cloth moistened with water or with a mild cleaning agent. Do not use any aggressive or flammable cleaning agents. 13.2.2 Clean measurement membrane NOTE!
Page 49
Shutdown 14 Shutdown 14.1 Dismounting WARNING! Risk of injury resulting from pressurized systems! Opening the pressurized system could result in people becoming injured by components that are slung away or by the escaping medium. Before starting with the mounting, make sure that the system is depressurized. Requirements: The plant has been de-pressurized.
Page 50
Insofar as the respectively applicable license terms justify a claim on the provision of source code or oth- er information, JUMO GmbH & Co. KG will provide the source code and the license texts on a conven- tional data carrier at the cost incurred for the provision of the data carrier.