EWM L1.04 - RC XQ Expert 2.0 Rob Operating Instructions Manual page 63

Hide thumbs Also See for L1.04 - RC XQ Expert 2.0 Rob:

Advertisement

Warning
24 Coolant f low warning
25 Flow 2
26 Flow 3
27 Flow 4
28 Wire stock warning
29 Low wire 2
30 Low wire 3
31 Low wire 4
32 Tacho error
33 Wire f eed motor excess current Excess current detected on wire f eed motor.
34 JOB unknown
35 Wire f eed motor slave excess
current
36 Slave tacho error
37 FAST bus f ailure
38 Incomplete component inf or-
mation
39 Half wave f ailure
40 Weak power grid
41 Cooling unit not recognised
47 Battery (remote control, type
BT)
only f or the XQ machine series
[1]
[2]
See technical data f or values and other switching thresholds.
8.4
Resetting JOBs (welding tasks) to the factory settings
All customised welding parameters that are stored will be replaced by the factory settings.
Instructions on how to reset welding tasks (JOBs) to the f actory setting can be f ound in the JOB man-
ager > see 5.6.2 chapter chapter.
099-00L104-EW501
16.08.2024
Resetting JOBs (welding tasks) to the f actory settings
Potential cause / remedy
Check the coolant supply.
Check the coolant level and top up if necessary.
Check f low and switching thresholds.
reserved
reserved
reserved
Check the wire f eeding.
reserved
reserved
reserved
Fault of the wire feeder - permanent overload of the wire drive.
JOB selection was not carried out because the JOB number is
unknown.
Excess current detected on wire f eed motor slave (push/push
system or intermediate drive).
Fault of the wire feeder - permanent overload of the wire drive
(push/push system or intermediate drive).
The wire f eeder is not connected (reset by actuating the auto-
matic circuit breaker of the wire f eed motor).
Check the Xnet component management.
Check supply voltage.
Check supply voltage.
A liquid-cooled welding torch was connected but no cooling unit
has been detected.
• Check the connection of the cooling unit
• Use a gas-cooled welding torch
Battery level is low (replace battery)
Rectifying faults