Error 26: Excess pilot arc module temperature
Category A
The power source is overheating.
Allow the switched-on machine to cool.
Fan is blocked, dirty or f aulty.
Check the f an and clean or replace it.
Air inlet or outlet is blocked.
Check the air inlet and outlet.
Error 32: Error I>0
The current detection is incorrect.
Request service.
Error 33: Error UIST
Voltage recording is f aulty.
Eliminate the short circuit in the welding circuit.
Remove the external sensor voltage.
Request service.
Error 34: Electronics error
A/D channel error
Switch the machine of f and on.
Request service.
Error 35: Electronics error
Slope error
Switch the machine of f and on.
Request service.
Error 36:
fault
conditions violated.
Switch the machine of f and on.
Request service.
Error 37: Excess temperature / electronics error
The power source is overheating.
Allow the switched-on machine to cool.
Fan is blocked, dirty or f aulty.
Check the f an and clean or replace it.
Air inlet or outlet is blocked.
Check the air inlet and outlet.
Error 38: Error IIST
Short circuit in the welding circuit bef ore welding.
Eliminate the short circuit in the welding circuit.
Request service.
Error 39: Electronics error
Secondary overvoltage
Switch the machine of f and on.
Request service.
099-00L104-EW501
16.08.2024
Rectifying faults
Error messages (power source)
59