Physical Disks

Only Dell supported 6.0 Gbps SAS physical disks are supported in the storage
array. If the storage array detects unsupported physical disks, it marks the disk
as unsupported and the physical disk becomes unavailable for all operations.
NOTE:
The MD3600f Series storage array must contain at least two physical disks
for proper operation. This is necessary because the physical disks are used to store
configuration information.

Physical Disk States

Table 4-1 describes the various states of the physical disk, which are
recognized by the storage array and reported in the MDSM application.
Table 4-1. RAID Controller Physical Disk States
Status
Mode
Optimal
Assigned
Optimal
Unassigned
Optimal
Hot Spare
standby
Optimal
Hot Spare in
use
Failed
Assigned,
Unassigned,
Hot Spare in
use, or Hot
Spare standby
Replaced Assigned
42
Planning: MD3600f Series Storage Array Terms and Concepts
Description
The physical disk in the indicated slot
is configured as part of a disk group.
The physical disk in the indicated slot
is unused and available to be
configured.
The physical disk in the indicated slot
is configured as a hot spare.
The physical disk in the indicated slot is
in use as a hot spare within a disk group.
The physical disk in the indicated slot
has failed because of an unrecoverable
error, an incorrect drive type or drive
size, or by its operational state being
set to failed.
The physical disk in the indicated slot
is replaced and is ready to be, or is
actively being configured into a disk
group.
Physical Disk
Status LED
Steady Green
Steady Green
Steady Green
Steady Green
Amber flashing
(150 ms)
Green flashing
(On 400 ms, Off
100 ms)