Page 1
INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-40-DEEP-XT BI-50-DEEP-XT BI-60-DEEP-XT BI-72-DEEP-XT BI-88-DEEP-XT SAFETY INFORM ATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or ot her flammable vapors and liquids in t he vicinit y of t his or any ot her appliance.
Page 2
Amant ii product . IMPORTANT INSTRUCTIONS............................3 UNPACKING AND TESTING APPLIANCE .......................4 GROUNDING APPLIANCE ............................4 LOCATING THE FIREPLACE .............................4 BI-40-DEEP-XT ................................5 BI-50-DEEP-XT ................................6 BI-60-DEEP-XT ................................7 BI-72-DEEP-XT ................................8 BI-88-DEEP-XT ................................9 SAFETY DRILL SCREW AREA ..........................10 HARD-WIRE INSTALLATION ..........................10 FOR BATHROOM USE ..............................11...
Page 3
IM PORTANT INSTRUCTIONS Read all inst ruct ions before inst alling or using t his heat er. Keep combust ible mat erials, such as furnit ure, pillows, bedding, papers, clot hes and curt ains at least 3 feet from t he front of t he heat er; keep t hem away from sides and rear as well. ’...
Page 4
UNPACKING AND TESTING APPLIANCE Carefully remove t he appliance from t he box. Prior to inst alling t he appliance, t est t o make sure t he appliance operat es properly by plugging t he power supply cord int o a convenient ly located 120 Volt grounded out let .
Page 5
BI-40-DEEP-XT This appliance has been t est ed Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 Voltage 120V AC 60Hz for fixed and locat ion dedicated elect ric Watt s 1500W M ax room appliances in t he United St at es and NO HEATER Canada.
Page 6
BI-50-DEEP-XT This appliance has been t est ed M odel Number Built -in Appliance accordance wit h t he UL St andard 2021 Voltage 120V AC 60Hz for fixed and locat ion dedicated elect ric Watt s 1500W M ax...
Page 7
BI-60-DEEP-XT Descript ion Built-in Appliance This appliance has been t est ed accordance wit h t he UL St andard 2021 Voltage 120V AC 60Hz for fixed and locat ion dedicated elect ric Watt s 1500W M ax room appliances in t he United St at es and NO HEATER Canada.
Page 8
BI-72-DEEP-XT This appliance has been t est ed Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 Voltage 120V AC 60Hz for fixed and locat ion dedicated elect ric Watt s 1500W M ax room appliances in t he United St at es and NO HEATER Canada.
Page 9
BI-88-DEEP-XT This appliance has been t est ed Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 Voltage 120V AC 60Hz for fixed and locat ion dedicated elect ric Watt s 1500W M ax room appliances in t he United St at es and NO HEATER Canada.
Page 10
SAFETY DRILL SCREW AREA There is a safet y drill screw area as show below. Please make sure t hat t he fix screws are in t his area. Sa fe ty d rill s cre w a re a (Da rk a re a ) T h e m a n u a l c o n tro l p a d p o s itio n HARD- W IRE INSTALLATION...
Page 11
“ ” At t ach t he wiring t o t he junct ion block. Please make sure t he live wire goes int o t he , t he “ ” “ ” neut ral wire int o and t he ground wire int o Put t he plate back and screw back.
Page 12
OUTDOOR INSTALLATIONS The BI-DEEP-XT series electric fireplaces are suitable for installation in outdoor areas protected from direct water impingement. In addition to maintaining the listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed appliance.
Page 13
It is recommended that two people remove the surround. The rough wall opening size of t he fireplace: " " " BI-40-DEEP-XT 12 1/ 2 BI-50-DEEP-XT 12 1/ 2 BI-60-DEEP-XT 12 1/ 2 BI-72-DEEP-XT 73 1/2 12 1/ 2...
Page 14
2. Remove the framing plates from the unit framing plat e 3. Re-fix the framing plates to the unit as the picture shows framing plat e...
Page 15
4. Bend up the framing plates. 5. Put the unit into the opening.
Page 16
6. Drive the mounting screws into the framing plates on the unit and the wall studs. framing plat e 7. After checking that the fireplace operates properly, cover the glass panel with protective plastic bag and install plywood or drywall. IMPORTANT NOTE: IF YOU WANT TO USE THE SUPPLIED SURROUND the thickness of the wall finish can only be 1”.
Page 17
8. Decorate the plywood or drywall with glazed tile, wallpaper, etc. Fireplace 9. Put back the trim that you’ve removed from the unit at STEP 1. t rim...
Page 18
M EDIA OPTIONS The BI-40-DEEP-XT is shipped w it h 1 set of FI-109-DIAM OND, BI-50-DEEP-XT and BI-60-DEEP-XT are shipped w it h 2 set s of FI-109-DIAM OND, BI-72-DEEP-XT and BI-88-DEEO-XT are shipped w it h 3 set s of FI-109-DIAM OND.
Page 19
FIRE GLASS M EDIA-LOG INSTALLATION 1. Take off the front clear glass. There is a bracket that holds the front glass as shows below. Unscrew the screw to take off the bracket. Turn around the bracket and insert it into the gap to hook and pull out the glass.
Page 20
OPERATION The fireplace can be operat ed eit her by t he swit ches located on t he left bot t om of t he fireplace unit or by supplied remot e cont rol. Plug t he fireplace int o a 15 Amp wall socket . M ANUAL OPERATION The main power ON/ OFF swit ch in posit ion O, t he fireplace is OFF.
Page 21
REM OTE CONTROL OPERATION For remot e t o funct ion make sure t he heat er is plugged in and main power swit ch located on t he bott om left hand side is at posit ion I. When operat ing t he remot e make sure you point t he remote t o t he cent re of t he fireplace and make sure each t ime you press t he butt on t he buzzer inside t he unit will beep once.
Page 22
INSTALLING WALL THERM OSTAT WALL THERM OSTAT W IRING DIAGRAM S W ire the wall thermostat prior to installing the fireplace. WALL THERM OSTAT W IRING(24 VAC) Install Wall Thermostat per instructions provided with kit and per the follow ing information: Turn off circuit breaker.
Page 23
REPLACEM ENT PARTS This list cont ains replacement part s DESCRIPTION QTY . BI-40-DEEP-XT BI-50-DEEP-XT BI-60-DEEP-XT BI-72-DEEP-XT BI-88-DEEP-XT 602030C 602030C 602030C 602030C 602030C BLOWER AND HEATER ASSEM BLY FIREPLACE BOX 10104010 10104010 10104010 10104010 10104010 SWITCH 601036 601036 601036 601036...
Page 25
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION ’ ’ Dim or no flame Flame LED s are burnt out Inspect t he LED s and replace t hem if necessary. ’ ’ Ember Ember LED s are burnt out Inspect t he ember bed LED s and glowing or dimming replace t hem if necessary.
Page 26
SERVICE HISTORY This heat er must be serviced annually depending on usage. Date Dealer Service technician Service Performed Special Concerns Name Name NOTES:...
Need help?
Do you have a question about the BI-50-DEEP-XT and is the answer not in the manual?
Questions and answers