Functional Description
Notes
 •  A sshowninthepictureabove,theAlarmInputmustbeenteredwiththeOpenorClosed
switch signals. Supplying power without entering the signals may damage the product.
P (Priority) :
Set the priority of Alarm Inputs. If more than one alarm is simultaneously activated,
the alarm with the highest priority activates before the others. Once the alarm is canceled, the
next highest priority alarm activates.
SEQ :
Enables setting up a sequence action for the camera in response to an alarm. Available
sequence actions are Home, Preset, Swing, Group, Tour, Trace and A.Pan.
※ F or the Auto Pan settings, the first number under the Number menu indicates the speed
while the second is the Tilt angle. (Refer below.)
ALM MOD P
SEQ
NO
Input 1 NO
1
Auto Pan 20/20
Input 2 NC
2
Auto Pan 20/20
Tilt Angle
Speed
MD Dwell Time :
When Motion Detection under the Preset Edit menu is selected, MD Dwell Time performs the
Tour or Group function.
While the camera is performing a sequence action, if motion is detected from a selected preset
location, the camera pauses the sequence action operation and starts monitoring the location
instead for a duration that is set under the MD Dwell Time menu.
If the motion is no longer detectable or the duration expires, the camera aborts the monitoring
operation and then resumes the sequence action.
82
SPEED DOME CAMERA
User Guide
29.2. Alarm Output
▶ Main Menu/Alarm Setting/Alarm Output
Setting 1,2 :
Main Menu
Enables selecting an Alarm Output method.
Camera Setting
- 1, 2, Motion, and Support Device indicate alarm input
Sequence Setting
ports, Motion Detection, and support device input. A total
P/T Setting
of 4 alarms, Motion Detection, and support devices can be
OSD Setting
set up to output alarms. 1 alarm output port can be used
Alarm Setting
for more than 2 alarm inputs and Motion Detection.

Initialize

Password Setting
Timer 1,2 :
Status
Enables selecting an Alarm Output method.
- On : Retains an alarm output for a set duration from a
minimum of 1 second to a maximum of 60 minutes
Alarm Setting
upon the alarm occurrence.
- Momentary : Retains an alarm output only until the alarm
Alarm Enable
OFF
Alarm Input
✽ The Alarm Output is equipped with a relay circuit. The
Alarm Output
operation of the alarm output port is as shown in the
MD Dwell Time
OFF
diagram below. (Normally Opened)
Alarm Output
Setting1
□ 1 □ 2 □ MD □ AUX
Setting2
□ 1 □ 2 □ MD □ AUX
Timer
OFF
Alarm Out OFF
Timer
OFF
OUT Off1
OUT Off2
Notes
 •   C onnectingthepowerconnectorandGNDincorrectlytotheNC/NOandCOMportsmay
cause a short circuit and fire, damaging the camera.
 •  T hemaximumpowercapacityofthebuilt-inrelayis30VDC/2A,125VAC/0.5A,and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera's
lifespan and damage it.
SPEED DOME CAMERA
is canceled.
NO
NO
COM
COM
NC
NC
Alarm Out ON