Installing Your Camera
Communication Protocol DIP Switch Settings (SW2)
* Coaxial communication automatically detects signals, and so does not require a
separate communication setup process.
ON
ON
OFF
SW2
Protocol Settings
•
Select a communication protocol for the camera
No
Protocol
SW2-#1
SW2-#2
1
AUTO DETECT
OFF
2
Samsung-T
OFF
3
Pelco-D
OFF
4
Pelco-P
OFF
5
Samsung-E
OFF
6
Panasonic
OFF
7
Vicon
OFF
8
Honeywell
OFF
9
AD
ON
10
GE
ON
11
BOSCH
ON
12
Resetved
ON
13
Resetved
ON
14
Resetved
ON
15
Resetved
ON
16
Resetved
ON
•
Baud Rate Settings
Select the transfer speed of a selected communication protocol.
No.
Baud Rate(BPS)
1
2,400
2
4,800
3
9,600
4
19,200
SPEED DOME CAMERA
SW2 Pin No.
Purpose
1~4
Protocol Settings
5~6
Baud Rate Settings
7
Response Mode Settings
8
Termination Settings
SW2-#3
SW2-#4
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
SW2-#5
SW2-#6
ON
ON
ON
OFF
OFF
OFF
OFF
ON
20
User Guide
•
Communication Response Settings
Select a communication response method for the camera and controller: Response or No
Response.
Function
SW2- #7
Response Mode Switch
•
Termination Settings
To prevent the attenuation of communication signals between the camera and controller,
the items at the end of line must be set up with the termination settings.
Camera Input Position
SW2- #8
Termination of Longest Path
ON
On the Path
OFF
* This model is provided with factory defaults of all DIP switches set to OFF. The default
settings are shaded in the table.
Notes
• T ouseathirdpartycontrollerwiththisproduct,pleasecontactourAfter-SalesService
or Technology Department.
• C ontrolsUsingDifferentProtocols
AD Protocol
Entering Camera OSD
3+Auxilary ON
Exiting Camera OSD
3+Auxilary OFF
ENTER
IRIS OPEN
ESC
IRIS CLOSE
• F ormoreinformationabouttheprotocols,refertoourofficialwebsite.
Camera ID DIP Switch Settings (SW1)
To set up camera IDs, refer to the "Camera ID Chart" next.
ON
SW1
SPEED DOME CAMERA
ON
OFF
Response
No Response
VICON Protocol
GE Protocol
IRIS OPEN
IRIS OPEN
IRIS CLOSE
IRIS CLOSE
IRIS OPEN
IRIS OPEN
IRIS CLOSE
IRIS CLOSE
ON
OFF
21
User Guide