Samsung SPD-3700 User Manual
Samsung SPD-3700 User Manual

Samsung SPD-3700 User Manual

Speed dome camera samsung-t protocol user's manual
Hide thumbs Also See for SPD-3700:

Advertisement

Ver 2.00E

SPEED DOME CAMERA

Samsung-T Protocol User's Manual
REV. 2.00E
Jan 2013
Samsung Techwin Co., Ltd.
Security Solution Division
Copyright(c) 1996-2013 SAMSUNGTECHWIN CO.,LTD

Advertisement

Table of Contents
loading

Summary of Contents for Samsung SPD-3700

  • Page 1: Speed Dome Camera

    Ver 2.00E SPEED DOME CAMERA Samsung-T Protocol User's Manual REV. 2.00E Jan 2013 Samsung Techwin Co., Ltd. Security Solution Division Copyright(c) 1996-2013 SAMSUNGTECHWIN CO.,LTD...
  • Page 2 All copy, reprint, and translation to other languages as a part of or all contents of this user's manual without permission of Samsung Techwin Co. Ltd. are expressly prohibited excep t for fair use within the scope of copyright law.
  • Page 3 - Revised notation errors of '2.8',2.9' command. - Revised notation errors of '2.10.6' command. Ver 1.40E 2009.09.17 - Added '2.11'command. - Protocol name is changed as 'Samsung-T' - Revised notation errors of '3. Protocol Samples' 2010.08.13 Ver 1.50E - Added parameters about SCP-2120/3120 - Revised notation error of '2.1' command...
  • Page 4: Table Of Contents

    Ver 2.00E <Table of Contents> 1.Protocol Frame Structure........................4 1.1 Transmission Packet Format....................4 1.2.Communication Timing Chart....................4 1.3.Transmission Packet Format....................5 2.Command..............................6 2.1 Pan/Tilt/Zoom/Focus/Brightness.................... 6 2.2 OSD Menu Control........................6 2.3 Preset Control......................... 7 2.4 Product Initialization........................7 2.5 Swing ............................8 2.6 Sequence Command........................
  • Page 5: Protocol Frame Structure

    Ver 2.00E 1.Protocol Frame Structure 1.1 Transmission Packet Format :RS-485/RS-422 Asynchronous Communication -Mode -Transmit Direction :Simplex/Half duplex -Start bit :1 bit -Data bit :8 bits -Parity bit :None -Stop bit :1bit -Baud rate :9600 bps 1.2.Communication Timing Chart Pic 1.Pan/Tilt Operation Timing Chart Please note that the Preset commands send a response only at the end of their executions.
  • Page 6: Transmission Packet Format

    Ver 2.00E 1.3.Transmission Packet Format <Command Packet Format> Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8 Byte9 Byte10 Byte11 Cam ID Host ID Cmd1 Cmd2 Data1 Data2 Data3 Data4 Checksum -STX(Start of Text): A0h -ETX(End of Text): AFh -Cam ID: Dome ID(01h~FFh) -Host ID: Host Controller ID(default:00h) -Checksum: The value of Modulo 256 equal to a total of Byte2 to Byte9 processed by 'Logical Not(~)'...
  • Page 7: Command

    Ver 2.00E 2.Command 2.1 Pan/Tilt/Zoom/Focus/Brightness Cmd1 Cmd2 Data1 Data2 Data3 Data4 Zoom Speed Direction1 Direction2 Pan Speed Tilt Speed /Focus Speed The frame above is located at Byte4 to Byte9 in the command packet. -Direction1~2 Direction1 is to process the Brightness and Focus commands. Command1 bit7 bit6...
  • Page 8: Preset Control

    Ver 2.00E 2.2.3 Menu Cancel(Esc) Cmd1 Cmd2 Data1 Data2 Data3 Data4 *The Focus command may be activated automatically in Normal (non-OSD Menu) mode. 2.3 Preset Control 2.3.1 Set Preset (Saves preset commands.) Cmd1 Cmd2 Data1 Data2 Data3 Data4 Send Receive "...
  • Page 9: Swing

    Ver 2.00E 2.5 Swing 2.5.1 Set Swing Speed & Time Cmd1 Cmd2 Data1 Data2 Data3 Data4 Send Return " " " " " Error P1: 00h=Pan Swing 01h=Tilt Swing 02h=Pan/Tilt Swing P2: 00h ~ 40h Swing Speed P3: 00h ~ 7Fh Swing Dwell Time(0 ~ 127sec) 2.5.2 Set Swing Cmd1 Cmd2...
  • Page 10: Ptz Trace

    Ver 2.00E 2.7 PTZ Trace 2.7.1 Set PTZ Trace Cmd1 Cmd2 Data1 Data2 Data3 Data4 Send Return " " " " " Error P1: 00h=Memory start 01h=RePlay start 02h=Delete P2: Pattern No.(0~3) 2.7.2 Stop PTZ Trace Cmd1 Cmd2 Data1 Data2 Data3 Data4 Send...
  • Page 11: Set Pan/Tilt Position Move 1(Relative Movement)

    Ver 2.00E 2.8 Set Pan/Tilt Position Move 1(Relative Movement) Cmd1 Cmd2 Data1 Data2 Data3 Data4 Send Return Error " " " " " P1: 00h=Pan 01h=Tilt P2: 00h=Right(or Down) 01h=Left(or Up) P3P4: Relative Movement Value (Resolution: 0.1deg) ->P3:High Byte, P4:Low Byte In case of tilting camera's direction, it is flipped.
  • Page 12: Special Command

    Ver 2.00E 2.10 Special Command The following special commands are developed in response to SI industrial requests. In case of Pan/Tilt/Zoom Position Parameter, please refer to Appendix 4.1, 4.2. Dome ID Host ID Cmd1 Cmd2 Data 0xA0 Command Data1~Data4 0xAF Check Sum 2.10.1 Call PT Position Cmd1...
  • Page 13 Ver 2.00E 2.10.5 Move Pan Position(Absolute Movement) Cmd1 Cmd2 Data1 Data2 Data3 Data4 Send Return " " " " " Error P1P2: Pan Position(Pulse)->P1:High Byte, P2:Low Byte 2.10.6 Move Tilt Position(Absolute Movement) Cmd1 Cmd2 Data1 Data2 Data3 Data4 Send Return Error "...
  • Page 14: Special Command 2

    Ver 2.00E 2.11 Special Command 2 2.11.1 Move PTZ Position and Track On/Off(Abs. position move) Special Command 2 is the protocol for the Auto Track's function. (In case of model is not have Auto Track function, this protocol is used only for the absolute position moving.) In case of Pan/Tilt/Zoom Position Parameter, please refer to Appendix 4.1, 4.2.
  • Page 15 Ver 2.00E 2.11.2 Call PTZ Position In case of Pan/Tilt/Zoom Position Parameter, please refer to Appendix 4.1, 4.2. Note ! The command can be usable, in case of indicated below models and firmware ver. later. SCP-2370/3370(H/TH) SCP-2370RH Model SCP-2330/2270(H) SCP-2371/2271/3371 Dome Version v1.02_110726 In case of using the related function with an old version instead of new...
  • Page 16: New Protocol

    Ver 2.00E 2.12 New Protocol The following New protocol are developed in response to SI industrial requests. Note ! The command can be usable, in case of indicated below models and firmware ver. later. SCP-2370/3370(H/TH) SCP-2370RH Model SCP-2330/2270(H) SCP-2371/2271/3371 Dome Version v1.02_110726 In case of using the related function with an old version instead of new one, please check the version before the installation in order for avoiding...
  • Page 17 Ver 2.00E 2.12.3 Freeze Cmd1 Cmd2 Data1 Data2 Data3 Data4 Send Return " " " " " Error P1: 00h=OFF / 01h=ON 2.12.4 OSD Setting Cmd1 Cmd2 Data1 Data2 Data3 Data4 Send Return " " " " " Error P1: 00h=Camera ID 01h=Camera Name02h=Preset Number 03h=Preset Name 04h=Sequence Status...
  • Page 18: Protocol Samples

    Ver 2.00E 3.Protocol Samples The following commands are examples of protocols with the camera ID set to 01h. Command Protocol Note OSD ON A0 01 00 00 B1 00 00 00 00 AF 4D Menu ON One shot AF A0 01 00 E0 15 00 00 00 00 AF 09 Call Zoom Pos.
  • Page 19: Appendix

    5~18666 (-15°~195°) * Note! Position is the data transformed the hexadecimal to decimal notation. 4.1.2 Zoom Position Range Model Remarks Zoom Range(Pulse) SPD-2300 0~1755 SPD-3000/3300 0~1770 SPD-1000 0~1174 SPD-3700/3750, SPU-3750/3700 0~1613 SPD-3350/3310 0~1608 SPD-2700 0~1589 SCP-2120 0~921 SCP-3120 32772~35952 SCU-2370 0~1613...
  • Page 20: Zoom Ratio Parameter Per Model

    Ver 2.00E 4.2.Zoom Ratio Parameter Per Model 4.2.1 Zoom Start Ratio Hexa Table ■ SPD-3700/3750, SPU-3750T/3700, SCP-2370/3370, SCU-2370 : 37X SCP-2370/3370/2371/3371, SCP-2370RH : 37X SPD-3350/3310, SCP-2330 : 33X SPD-2700, SCP-2270/2271 : 27X 0x0000 0x0542 0x0609 0x0643 0x0238 0x055F 0x0613 0x0646...
  • Page 21: Scp-3120 Digital Zoom Parameter

    Ver 2.00E 4.3.SCP-3120 Digital Zoom Parameter Digital Zoom Position Parameter 1.08 0x0a 1.17 0x15 1.25 0x20 1.33 0x2a 1.42 0x35 0x40 1.58 0x4a 1.67 0x55 1.83 0x6a 1.92 0x75 0x80 2.17 0x87 2.42 0x91 2.58 0x99 2.83 0xa3 0xab 0xb5 0xc0 0xcd 0xd6...