Summary of Contents for Eaton xStorage XSTHS1P036BP05V1
Page 1
xStorage Hybrid system xStorage Hybrid Lorem ipsum dolor sit amet Single Phase Inverter Lorem ipsum dolor sit amet...
Page 2
Corporation’s (“Eaton”) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser.
When the sun is off, the load will be supported by battery to enhance self-consumption. If the power supply from the batteries is not sufficient, the grid will support the load demand. Figure 4. Self-consume operation mode EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 8
PEAK SHIFT: This mode is designed for time-use mode customer. The customer is able to set up the charging/discharging time & power via inverter screen or APP. Figure 6. Peak shift operation mode EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
5 min This sign shows danger of hot surface! Refer to the operating instructions. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Moreover, if heated strongly by the surrounding fire, acrid or harmful fume may be emitted. 1.4.2 Safety Datasheet For detailed information please refer to the provided battery safety datasheet. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
• Lifting and transporting the inverter and battery must be carried out by more than 2 people. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Check the following parts list to ensure it is complete. Delivers a total system separately on site to client, this consists of: Inverter Figure 7. Inverter box content PACK5.1 Figure 8. Mounting panel box content EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
The maintenance procedures relating to the product have not been followed to an acceptable standard; • Force majeure (violent or stormy weather, lightning, overvoltage, fire etc.); Damages caused by any external factors. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
The xStorage Hybrid must also not be installed in potentially explosive atmospheres for gas cylinders that are heavier than air gases and have a vent clamp in accordance with AS / NZS 3000. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
The xStorage Hybrid must be mounted to ensure the highest point is not more than 2.2m above the ground or the platform. A shelter must be installed above the Energy Storage System. Figure 19. Limited Distance of Installation to Neighboring Objects EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Step 1. Remove the battery and inverter from the packaging box. Figure 20. Unpacking the inverter and battery 2.2.1 Battery Installation Step 2. Assemble the battery mounting panel on the battery. Figure 21. Assemble Battery Mounting Panel EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 22
Step 4. Remove the debris baffle and secure the battery to the wall with screws and gaskets. Figure 23. Battery Installation-Mounting on the Wall Step 5. To assemble the second (and all other) battery, repeat step 6 and 7, respectively. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Figure 24. Battery Installation Second Battery Installation 2.2.2 Inverter Installation Step 6. To assemble the second (and all other) battery, repeat step 6 and 7, respectively. Figure 25. Inverter Installation EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 24
Stripping length of the insulated conductors approx.13mm Stripping length of the outer sheath of the AC cable approx.53mm The PE conductor must be 10mm longer than the Land N conductors EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 25
5. Assembly the plug shell ,adapter as below picture, Push the adapter and shell by hand until a “Click” is heard or felt. Figure 32. Assembling the adapter 6. Plug the AC connector into the jack for the AC connection by hand until a “Click” is heard or felt. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 26
Step 8-2. Connect the Backup and Grid cables in advance according to the connector mode and connect them to the Backup and Grid board connectors in turn. Figure 34. Cable Box Bottom View, Wiring Connectors EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 27
Step 10. Connect the power cables of the bottom battery from Step 4 to the side terminals of the top battery. Make sure that red connects to red and black connects to black. Figure 36. Wiring the Battery Power Cable EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 28
AC cables, the meter communications cable METER, and the Ethernet cable LAN. Then close the cable box cover. The installation is now complete. Figure 37. PV Wiring Step 12. Close the lid and tighten the screw. Figure 38. Closing the unit EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 29
The method of anti-islanding protection is Method(c) After the first installation of the machine, the battery must be forcibly charged to 100% SOC before normal use, in order to calibrate SOC. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
External CT should be placed near the power grid. If CT test pass but inverter still can’t achieve export power (power is not controllable or always 0 power output). Please check installation location of the CT. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
2.5 Single Line Diagram The single line diagrams of DC-, AC-coupled system are as below: Figure 44. DC-coupled system Figure 45. AC-coupled system 1 EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 33
Figure 46. AC-coupled system 2 EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Other areas except Australia, New Zealand, South Africa, etc., are applicable to the following wirings: Figure 48. N and PE cables in the Main Panel shall be wired separately. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Step 7. If backup load is applied, turn on the Backup switch. Step 8. Close the battery switch cover and the outer shell of the cable box. The Backup switch is only used when a backup load is applied. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Battery in wet environment: Stay out of the water and don’ t touch anything if any part of the battery, inverter, or wiring is submerged. Do not use a submerged battery again and contact the service engineer. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Enter the setting interface. Up button: Move cursor to upside or increase value. Button Function Down Button: Move cursor to downside or decrease value. ENT Button: Confirm the selection. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 38
Temperature sensor malfunction (BMS Internal fault) 0x340 BYTE 6,7 BIT4 Battery Cell malfunction (voltage difference between cells exceeds 1V) 0x340 BYTE 6,7 BIT5 Communication failure (BMS Internal fault) EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 39
Table 6. Battery level indication – when there is no fault or Alarms Status Charging Discharge Battery level indicator 0–25% Blinks twice Off Constantly On 26–50% Blinks twice Battery level 51–75% Blinks twice Off 76–100% Blinks twice On EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Critical load (BACKUP) current CURR: 0.00A 4.2.10 Power Interface Explanation POWER Inverter real - time total power INV: W Grid real-time total power GRID: W Load real-time total power LOAD: W EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Avoid using the same PIN for multiple inverter deployments. To protect and protect yourself from any cyberattack, Eaton strongly recommends that you change your password after completing commissioning. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
1 to 15) 8: CEI SPI CTRL 9: GFCICHK ENB 10: DOD ENABLE 11: GENERATOR 12: CT OR METER 13: AC COUPLE 14: CT DIRECTIO 15: AFCI EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 45
CHA STAR2: 00:00 shifting. CHAR END2: 00:00 Press UP/DOWN button to change the value. DIS START2: 00:00 Press ENTER to confirm. DISC END2: 00:00 Press ESC button to return. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 46
2: ENABLE 6. Remote Control enable Interface Explanation The power switch of the machine can be realized REMOTE CTRL through remote control. 1:DISABLE Default option is DISABLE. 2: ENABLE EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 47
2. ENABLE frequency protection range measured by AC will be relaxed to + -10%, the frequency protection range at 50Hz is 45Hz-55Hz, and that of 60Hz is 54Hz-66Hz. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 48
The inverter locks for protection after the 5th electric arc fault. The inverter can operate normally after the fault is solved. Default Enable is Disabled If enabled options levels “1-9”. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
DOWN button to move corresponding options. BAT TYPE Press ENTER button to enter the selected menu; 1: LFP Select the OTHER_Li enters button to enter the OTHER_Li interface; EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 50
Press Enter to move cursor backward, confirm input INPUT: 25 and return to battery parameters interface; UNIT: A Press ESC button to move cursor forward and return to battery parameters interface. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 51
Press UP/DOWN button to increase or decrease the WAKE-UP TIME input figure. INPUT: 060min Press Enter button to move cursor backward, confirm input and return to battery parameters interface. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 52
1. Disable: Do not force to wake up battery packs. FORCE WAKE 2. Enable: Force to wake up the battery pack 1:DISABLE immediately if the battery is not connected. 2: ENABLE EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Select 3, 4, the corresponding mode will be selected and return to the parameter setting interface). Press ESC button to cancel the input and return to operation parameters interface. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 54
Enter option 1 to adjust the maximum volt of the INV. VOLT MAX Enter option 2 to adjust the maximum volt of the grid. 1:INV MAX 2: GRID MAX EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 55
Press ESC button to cancel the input and return to operation parameters interface; Value range The value should range between 150V and 220V which (150~200V) varies with different standards. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 56
Enter option 1 to adjust the minimum frequency of FREQ MIN the INV. 1:INV-MIN Enter option 2 to adjust the minimum frequency of 2: GRID MIN the grid. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 57
1: ENABLE Enter the option 2 to adjust the exact value of the 2: VOLT voltage when power start to derate. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 58
1: ENABLE Enter the option 2 to adjust the exact value of the 2: FREQ frequency when power start to derate. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 59
. 1: DISABLE 2: ENABLE POW SI RATE Interface Explanation The input value of power rising rate. Default value is 100%. POW SI RATE INPUT: 100% EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Press ESC button to move DATE: 2020-07-19 cursor forward and return to setup interface. TIME: 10:01:12 The input value should range between 2000 and 2099. WEEK: Monday EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
The countdown Auto test . . . will last for 603 seconds. You can press the ESC Key to exit 603 s the self-test. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 62
Tes: 228.4V 0.19s • Current measured voltage or frequency value: The Cur: 228.7V Pass! measurement value of grid voltage or frequency during the coincidence. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 63
Tes: 50.0Hz 98ms • Current measured voltage or frequency value: The Cur: 50.0Hz Pass! measurement value of grid voltage or frequency during the coincidence. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Press ESC button to return to inquiry interface. DSP VER: 1.0.0 23112574 4. REGION Interface Explanation This interface displays the current selection of region. REGION Press ESC button to return to inquiry interface. Aus-A EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 65
After connecting the meter, you can view the METER STATUS communication status of the meter here, success or COMMUNICATE OK fail. Press ESC button to return to Inquiry interface. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
PV: 0.0KWH PV power generation. METER: 0.0KWH Electric energy selling to Grid. GRID: 0.0KWH Electric energy buying from Grid; LOAD: 0.0KWH Power consumption of Load; CHARG: 0.0KWH DISCH: 0.0KWH EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Step 5: after the battery is charged, switch off the battery charger and then the battery DC breaker. Disconnect the DC cables and then press the battery “start key” for 3 second to switch off the battery PACK. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
1. Successful connection status with serve: NET light keeps on after the logger powered on. 2. Logger running normally: READY light Flashes. 3. Successful connection status with inverter: COM light keeps on. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
All lights are extinguished immediately. 1. All lights are extinguished after 4s. Long press 10s Resetting the stick logger. 2. READY light flashes fast for 100ms. Do not remove waterproof plug. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
BMS Under Volt BMS Chg Temp Low BMS Severe Over Volt BMS Severe Over Temp BMS Updating BMS Program Version Err BMS Program Update Fail CT Reverse Clock Initiate Fail EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
INV DC Over Ambient Over Temp Sink Over Temp Grid Relay Fault DisChg Curr Over Chg Curr Over Current Sensor Fault INV Abnormal EPS Relay Fault Always Overload SCI Fault EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
(2) Contact customer service if error warning continues. Communication Fault (1) Restart the inverter and wait until it functions normally. (2) Contact customer service if error warning continues. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Page 74
(2) Contact customer service if error warning continues. Clock Initiate Fail (1) Restart the inverter and wait until it functions normally. (2) Contact customer service if error warning continues. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
(i.e., the battery has not been charged for two weeks or more). Please contact us in time if there are any conditions that could not be explained in the manual. EATON XSTORAGE HYBRID SINGLE PHASE INVERTER INSTALLATION MANUAL MN700012EN June 2024 www.eaton.com...
Monitoring through applications Note: At Eaton we do not currently have a Mobile or Web application capable of connecting to products. Customer can connect their own application such as a Home assistant to monitor their production, consumption and be notified of possible events appearing on its installation.
Page 80
Their use in whatever form is subject to prior approval Eaton Manufacturing LP, Morges Branch by Eaton. The same applies to Trademarks (especially Eaton, Moeller, Chemin de Maillefer 61, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as 1052 Le Mont-sur-Lausanne, referenced on Eaton Internet pages and Eaton order confirmations.
Need help?
Do you have a question about the xStorage XSTHS1P036BP05V1 and is the answer not in the manual?
Questions and answers