The DX164-W is a fixed installation I/O Expander for Allen & Heath 96kHz digital mixing systems. It provides 16 remote controlled mic/line preamps and 4 XLR line outputs. It connects to the mixer over a single Cat5 cable.
A second DX164-W, DX012 or DX168 can be connected when running in Cascade mode. Alternatively, a redundant connection can be made to compatible hardware.
The DX164-W can be operated freestanding, mounted in a floor pocket, mounted on a wall, or flush mounted in a wall. Different power options are provided to suit the application.
Update the mixing system to the latest available version of firmware before connecting the DX Expander. The unit might operate incorrectly when running earlier firmware.
Redundant mode – to compatible hardware only
Cascade mode – add second DX164-W, DX012 or DX168
Replacement of the IEC AC inlet module and mains wiring for permanent installation must be performed by a qualified electrician. See instructions later in this guide.
To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions.
Mounting on a wall
Use the mounting frame AA11504 in the orientation shown below. Fix the frame to the wall using appropriate fixings or screws for the type of wall, then align the threaded inserts on the sides of the DX164-W with the frame, and secure the unit in place with the 6x M4 6mmT20 screws provided.
Flush mounting in a wall
Use the mounting frame AA11504 in the orientation shown below. Align the threaded inserts on the sides of the DX164-W with the frame, and secure the unit in place with the 6x M4 6mm T20 screws provided. Connect the power and Cat5 cable/s, then fix the assembly to the wall using appropriate fixings or screws for the type of wall.
Floor mounting
The DX164-W can be mounted in a floor box / stage pocket / dip trap. It must be installed in accordance with local installation and wiring regulations. We recommend using the ACE Backstage 174SLBK stage pocket system for use with the DX164-W.
Other options
The DX164-W dimensions will fit in a 11x11" NEMA Type 1 / IP10 box or equivalent. A custom mounting frame is required.
Replacement of the IEC AC inlet module and mains wiring for permanent installation must be performed by a qualified electrician and carried out in accordance with local wiring regulations.
To replace the IEC module:
POWER DISCONNECTION
The mains supply disconnect device is the installation all pole circuit breaker or the switched fused outlet which must be labelled and must be accessible so as to be readily operable when the appliance is in use.
Mic/Line XLR Inputs | Balanced XLR, +48V phantom power |
Mic/Line Preamp | Fully recallable |
Input Sensitivity | -60 to +15dBu |
Analogue Gain | +5 to +60dB, 1dB steps |
Pad | -20dB Active PAD |
Maximum Input Level | +30dBu (PAD in) |
Input Impedance | >4kΩ (Pad out), >10kΩ (Pad in) |
Mic EIN | -127dB with 150Ω source |
Analogue XLR Outputs | Balanced, Relay protected |
Output Impedance | <75Ω |
Nominal Output | +4dBu = 0dB meter reading |
Maximum Output Level | +22dBu |
Residual Output Noise | -92dBu (muted, 20-20kHz) -90dBu (muted, 20-40kHz) |
Operating Temperature Range | 0°C to 40°C (32°F to 104°F) |
Power | |
Mains Voltage Operating Range | 100-240V AC, 50/60Hz |
Mains Power Consumption | 35W max |
DC Input | 12V DC, 3A max |
Dimensions and Weight | Width x Depth x Height x Weight |
DX164-W | 210 x 87 x 210 mm x 3.2kg (8.25" x 3.5" x 8.25" x 7lbs) |
Check that you have received the following with your DX164-W unit:
Cat5e or higher STP cable is required for DX connections with a maximum cable length of 100m per connection.
Allen & Heath can provide a number of Cat5e and Cat6 cables suitable for use with the DX Expander:
AH9997 | 2m CAT5e cable with Neutrik EtherCon locking connectors |
AH10887 | 100m drum of CAT6 cable with Neutrik EtherCon locking connectors |
AH10886 | 80m drum of CAT6 cable with Neutrik EtherCon locking connectors |
AH10885 | 50m drum of CAT6 cable with Neutrik EtherCon locking connectors |
AH10884 | 20m drum of CAT6 cable with Neutrik EtherCon locking connectors |
Contact your local A&H dealer for more information.