Download Print this page

Yetter TITAN 2967-042A Operator's Manual

Residue manager for john deere hd coulter

Advertisement

Quick Links

YETTER MANUFACTURING CO.
FOUNDED 1930
Colchester, IL 62326-0358
Toll free: 800/447-5777
309/776-3222 (Fax)
Website:
www.yetterco.com
E-mail:
info@yetterco.com
2967-042A
TITAN
RESIDUE MANAGER
FOR
JOHN DEERE HD COULTER
OPERATOR'S MANUAL
PART IDENTIFICATION
2565-955_REV_A1 ▪ 08/2024

Advertisement

loading
Need help?

Need help?

Do you have a question about the TITAN 2967-042A and is the answer not in the manual?

Questions and answers

Summary of Contents for Yetter TITAN 2967-042A

  • Page 1 2967-042A TITAN RESIDUE MANAGER JOHN DEERE HD COULTER OPERATOR’S MANUAL PART IDENTIFICATION 2565-955_REV_A1 ▪ 08/2024 YETTER MANUFACTURING CO. FOUNDED 1930 Colchester, IL 62326-0358 Toll free: 800/447-5777 309/776-3222 (Fax) Website: www.yetterco.com E-mail: info@yetterco.com...
  • Page 2: Foreword

    It is the user’s responsibility to deliver his machine to the Yetter dealer who sold him the product for service or replacement of defective parts, which are covered by the warranty policy.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS A brief description of signal words that may be used in this manual: DANGER: Indicates an imminently hazardous situation which, if not avoided “will” result in death or serious injury. This signal word is to be limited to the most extreme situations. WARNING: Indicates a potentially hazardous situation which, if not avoided, “could”...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS FOREWORD ........................2 SAFETY .......................... 2-3 BOLT TORQUE ......................... 5 INSTALLATION INSTRUCTIONS .................. 6-7 OPERATION ........................8 MAITENANCE ......................9-13 PART IDENTIFICATION ..................... 14-15 OPTIONAL EQUIPMENT 2967-186 FLOATER WHEEL L.H. ASSEMBLY SHOWN (2) REQUIRED PER ROW...
  • Page 5: Bolt Torque

    BOLT TORQUE Before operating the Titan Residue Manager for the first time, check to be sure that all hardware is properly torqued. Check all hardware again after approximately 50 hours of operation and at the beginning of each planting season. If hardware must be replaced, be sure to replace it with hardware of the equal size, strength, and thread type.
  • Page 6: Installation Instructions

    INSTALLATION INSTRUCTIONS STEP 1. Install the 2966-111 mount bracket and the JD coulter using the M12 X 45MM locknuts. Tighten the bolts snug where the coulter can be moved as needed...
  • Page 7 INSTALLATION INSTRUCTIONS STEP 2. Attach the residue manager arm/wheel assembly using the M16 X 45 Hex Flange Screw, bushing, and locknuts.
  • Page 8: Operation

    OPERATION NOTICE: Where rocks are present the residue manager should be set in the “float” position, not locked down. STEP 1. Adjust the residue manager to move crop residue aside and not move any soil. Adjustments to the residue manager may have to be made when changing field conditions and type and amount of residue. Use the handle for leverage when changing depth settings.
  • Page 9: Maintenance

    MAINTENANCE BEARING ASSEMBLY AND LUBRICATION Practice Safety Understand and practice safe service procedures before doing work. Follow ALL the operating, maintenance and safety information in the equipment operator manual. Clear the area of bystanders, especially small children, when performing any maintenance or adjustments.
  • Page 10 MAINTENANCE NOTICE: Be certain to align the grease fitting with the slot in the wheel and the hubcap so that the grease can flow freely. Grease must fill this Hubcap cavity.
  • Page 11 Alternative Lubricants Conditions in certain geographical areas may require special lubricants and lubrication practices which do not appear in the operator's manual. If there are any questions, consult Yetter Manufacturing Co. to obtain latest information and recommendation. PART # DESCRIPTION OUNCES OF GREASE 13”...
  • Page 12 MAINTENANCE Lubrication Symbols Lubricate with grease at hourly interval indicated on symbol. Lubrication Intervals NOTICE: The recommended service intervals are based on normal conditions; severe or unusual conditions may require more frequent lubrication. Perform each lubrication and service procedure at the beginning and end of each season. Clean grease fittings before using grease gun, to avoid injecting dirt and grit into the bearing.
  • Page 13  Clean machine thoroughly to remove all dirt, debris and crop residue, which would hold moisture and cause rusting.  Inspect machine for worn or broken parts. See your Yetter Farm Equipment dealer during the off-season so that parts or service can be acquired when machine is not needed in the field.
  • Page 14: Part Identification

    PART IDENTIFICATION...
  • Page 16 East, the South, the West and now north into Canada. We’re even getting orders from as far away as Australia and Africa. So, when you buy Yetter products . . .you’re buying a name that’s recognized. A name that’s known and respected. A name that’s become a part of American agriculture and has become synonymous with quality and satisfaction in the field of conservation tillage.