To Use History Mode - Avocent DSR2020 Installer/User Manual

Avocent dsr switch installer/user guide
Hide thumbs Also See for DSR2020:
Table of Contents

Advertisement

76
DSR Switch Installer/User Guide

To use History mode:

1.
Press
Ctrl-F9
2.
Press one of the following key combinations to perform the indicated action:
: Move to the top of the buffer.
Home
: Move to the bottom of the buffer.
End
Page Up
Page Down
Up Arrow
Down Arrow
Ctrl-F8
Ctrl-F9
mode enabled.
Ctrl-F10
mode enabled.
Ctrl-F11
Press
Enter
screen will reappear.
3.
When finished, press
DSRIQ-SRL module pinouts
Table D.1: DSRIQ-SRL Module Pinouts
DB9-F
Host Signal
Pin
Name/Description
1
DCD - Data Carrier Detect
2
RXD - Receive Data
3
TXD - Transmit Data
4
DTR - Data Terminal Ready
5
GND - Signal Ground
6
DSR - Data Set Ready
7
RTS - Request to Send
8
CTS - Clear to Send
9
N/C - Not Connected
. The mode will display as History.
: Move up one buffer page.
: Move down one buffer page.
: Move up one buffer line.
: Move down one buffer line.
: Enters Configuration mode. The Configuration screen will appear.
: While in Configuration mode, return to the previous screen with History
: While in Configuration mode, return to the previous screen with On-Line
: Clears the history buffer. If you choose this option, a warning screen will appear.
to delete the history buffer, or
to exit History mode and return to On-Line mode.
Ctrl-F10
to cancel the action. The previous
Escape
SRL Signal
Signal Flow
Name/Description
Out of SRL
DTR - Data Terminal Ready
Out of SRL
TXD - Transmit Data
In to SRL
RXD - Receive Data
In to SRL
DSR - Data Set Ready
N/A
GND - Signal Ground
Out of SRL
DTR - Data Terminal Ready
In to SRL
CTS - Clear to Send
Out of SRL
RTS - Request to Send
N/A
N/C - Not Connected

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsr1020Dsr4020Dsr8020Dsr switch