  • Page 1 ACRsmart Technician and User Instruction Manual...
  • Page 3: Table Of Contents

    Milking with automatic unit removal ..................16 5.3.2 Manual milking ......................... 17 5.3.3 Indication of milk presence ...................... 17 5.3.4 Maximum milking time ......................17 Detachment operation ......................... 18 This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 4 Parameter reading ........................25 GENERAL RECOMMENDATIONS ...................... 27 Positioning ........................... 27 Sensitivity ............................. 27 Configurations ..........................28 TROUBLESHOOTING .......................... 29 SPARE PARTS DIAGRAM ........................30 This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 5: General Information

    Certain company and product names used throughout the document are trademarks of their respective owners. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 6: General Warnings

    Any failure to observe the warnings provided in this manual may lead to equipment malfunctions or damage to the system. 2.1.4 Limitation of liability InterPuls S.p.A. declines all liability for damage to persons, animals and/or things caused by incorrect use of the equipment. Prior using the product 2.2.1 Requirements and rules for personnel and Safety Rules...
  • Page 7: Connection

    Use powder, foam or halogen extinguishers which must be positioned next to the device. Operating personnel must receive adequate instruction on how to use the extinguishers. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 8: Normative References Applied

    • UKCA (UK Conformity Assessed) • USA: • FCC Federal Communications Commission Canada: • IC Industry Canada Marking 2.6.1 Dataplates affixed to the device This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 9: Description Of The Device

    60kPa MAX @25°C (17.71 ‘’Hg MAX @77°F) Operating temperatures (environment) +5ºC ÷ +45ºC (+41ºC ÷ +113ºF) Transport/storage temperatures -20ºC ÷ +70ºC (-4ºC ÷ +158ºF) This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 10: Wiring Diagram

    LE “Common” Black Yellow “Front” LE pulsation Blue Green CV (to valve) Blue Pink CV “Common” Black Brown CV (to cylinder) Brown HFS sensor This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 11: Connection Diagram For Sheep And Goat

    Pink Black BLUE +24VDC Green Blue Front Yellow Blue Common Black White Rear Brown Grey BLUE LE30 - 24 VDC (Pulsator) + 24 VDC This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 12: Description Of The Device

    D) Milking process start button with automatic detachment, continuous pressure for 3”, stimulation start E) Combination of keys for accessing the washing or programming mode This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 13: Display During Operation

    - Manual milking milking Code dt Detachment Alarm of milking without continuous Code AL (flashing) flow or detachment due to the max milking time E.t. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 14: Description Of The Functions

    5” QUICK-LIFT operation Removal or release of the milking unit Start automatic milking via remote control (cylinder with AS or remote AUTO-START operation button) This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 15: Wash

    Do not press the key and do not press the quick-lift switch during the washing cycle: the unit would be removed from the washing plate. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 16: Milking

    The sole lower line indicates the absence of milk and therefore the final delay count In each milking stage, the two vertical lines flash following the frequency of the pulsator This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 17: Manual Milking

    If this limit is reached, the unit detachment operations start automatically. If parameter Alarm AL = on, the anomaly is signalled via an alarm This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 18: Detachment Operation

    (stand- by); press the key to start a new milking session. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 19: Stimulation

    By setting stimulation ratio (parameter S.r.) on value 0, upon start of the stimulation, the liners stay completely closed and the pulsation stops until the end of stimulation time (S.t.). This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 20 As soon as a Continuous If a Continuous Flow is not Flow signal is detected detected, the Detachment again, the milking process Operations start continues normally This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 21: Alarm

    Therefore, via the button or via the remote Quick-Lift switch, you can move arms from one side of the milking parlour to the other. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 22: Programming Mode

    To exit the programming mode press and hold the keys for 5”; the panel is then automatically restarted, and the version of the software currently installed in displayed. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 23: Programming Parameter Table

    120ppm) to 30÷250) STIMULATION Duration of stimulation 10÷90 Seconds TIME STIMULATION Pulsation ratio during stimulation 0:100 ÷ 100:0 Pulsation ratio 30 (= 30:70) RATIO This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 24 ALARM oF - on control the milk flow or if you want the alarms not to be displayed This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 25: Parameter Reading

    The dot lit-up indicates that the value must be multiplied by 10 >> 80 seconds Stimulation time – tS: forced stimulation automatic stimulation no stimulation This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 26 Swing-Over arm (the CV channel controls a piston that moves the arm from right to left and vice versa) This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 27: General Recommendations

    JUMPER 2 OPEN JUMPER 1 OPEN < 100 gr/min 2660 6.42 +/- 0.07 JUMPER 2 OPEN JUMPER 2 - OPEN JUMPER 1 - CLOSED This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 28: Configurations

    = 0.2 seconds Decrease the Final Delay Goats or sheep F.d. parameter = 8 seconds If the system continues to detach too soon, open both jumpers This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 29: Troubleshooting

    Incorrect setting of Shut-Off during milking and during channel (e.g. CV20) or on N.C. if Solenoid parameter washing is used an ATM channel (e.g. CV30) This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 30: Spare Parts Diagram

    5630032_2024.06_EN Original instructions 9 SPARE PARTS DIAGRAM This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
  • Page 32 | InterPuls | Albinea | Via F. Maritano 11 | 42020 | Reggio Emilia | Italy | T +39 0522347511 | F +39 0522 348516 | Sales.Albinea@milkrite-interpuls.com | www.milkrite-interpuls.com...