Page 1
Instruction Manual, Operation and Maintenance original instructions ACR Puls sw.5.4 InterPuls S.p.A. Via F. Maritano, 11 - 42020 - Albinea (RE) – ITALY Tel. +39 0522 347511 Fax +39 0522 348516 sales@interpuls.com InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF -...
Page 2
TYPE OF DOCUMENT Instruction, Use and Maintenance Manual DOCUMENT CODE 5500066-06_MI_10.13 - EN EDITION Rev.06 PRODUCT ACR Puls sw.5.4 YEAR OF MANUFACTURE 2013 InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 2...
Stimolazione ..........................11 Automatic-milking-mode ......................12 Manual-milking-mode ....................... 14 Alarm ............................15 Removal procedures ........................ 15 Presence of milk ........................15 InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 3...
Page 4
Tabella dei parametri di programmazione ................18 GENERAL RECOMMENDATIONS ................19 Sensor Positioning ........................19 Sensitivity ..........................19 Fine tuning ..........................20 InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 4...
Any failure to observe the warnings provided in this manual may lead to equipment malfunctions or damage to the system. 1.1.4 Limitation of liability InterPuls S.p.A. declines all liability for damage to persons, animals and/or things caused by incorrect use of the equipment. Prior using the product 1.2.1...
Directive 2006/42/EC (Machinery Directive). Marking 1.6.1 Dataplates affixed to the machine Safety decals WARNING The removal or damaging of safety decals is strictly prohibited. InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 6...
24 VDC Power consumption of the panel 100 mA Power consumption of the system ACR + CV20 + LP20: 600 mA InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 7...
- Instruction Manual,Operation and Maintenance 5500066-06 5500066-06_MI_10.13-EN original instructions WIRING DIAGRAM 2.3.1 ACR+CV20+LE20 wiring diagram InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 8...
LE20 pulsation “R” (brown) grey pink LE20 & CV20 common (black) blue 24VDC (-) 24VDC (+) Remote Start / Autostart Quick-Lift InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 9...
50:50 & frequency set at parameter 21 (factory set 20ppm). The Washing-Mode can also be activated manually by pressing the DIS button. To quit Washing-mode, press the STOP button. InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED...
In the programming mode, it is possible to set a forced stimulation cycle at the start of each milking for a definite time (“Stimulation-Time”). InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED...
“Vacuum/Pulsation Delay”, the pulsator is activated and the flow-sensor opens the shut-off valve the display starts showing milking time InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 12...
Page 13
“Milk Flow” is NOT detected before the “Final Delay” elapses, before the “Final Delay” elapses, the “Removal-Procedures” start and the milking ends. the milking proceeds regularly InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 13...
It is possible to switch from Manual-Milking-Mode to Automatic-Milking-Mode and back by simply pressing NOTE or STOP button are not pressed, the Manual-Milking-Mode will end only when “Maximum-Milking-Time” elapses (15min). InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 14...
Parameter “Continuous-Flow” in order to reduce milking time, decrease the value attributed to Parameter “Continuous-Flow” in order to obtain a total emptying of the udders. InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 15...
To activate the “Test Mode” press the DIS button and then the button. To deactivate the “Test Mode” just press STOP. InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 16...
1 to set the value “Y” = YES, press 0 to set the value “N” = NO To quit the programming mode, press ENTER. InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED...
Vacuum/Pulsation Delay 0 ÷ Sistem starting: 1 – wash 2 – stand by 3 – last 1 – 2 – 3 InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 18...
6,32 +/- 0,07 JUMPER 1 OPEN JUMPER 2 CLOSED < 100 gr/min 2660 6,42 +/- 0,07 JUMPER 1 OPEN JUMPER 2 OPEN InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 19...
“high-line” & “mid-line” systems: decrease parameter 32 (continuous flow) to 0,3 seconds; decrease parameter 34 (final delay) to 6 seconds. InterPuls S.p.A. THIS MANUAL IS THE PROPERTY OF - ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED MI - 20...
Need help?
Do you have a question about the ACR Puls sw.5.4 and is the answer not in the manual?
Questions and answers