INSTALLATION ............................8 Setting of washing vacuum ......................9 MAINTENANCE ............................ 10 Periodical maintenance ....................... 10 SPARE PARTS DIAGRAM ........................11 TROUBLESHOOTING .......................... 12 This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
Certain company and product names used throughout the document are trademarks of their respective owners. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
2.1.4 Limitation of liability InterPuls S.p.A. declines all liability for damage to persons, animals and/or things caused by incorrect use of the equipment. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
Use powder, foam or halogen extinguishers which must be positioned next to the device. Operating personnel must receive adequate instruction on how to use the extinguishers. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
3 DESCRIPTION OF THE DEVICE General features Interpuls SANIVAC is an innovative valve that aims to improve the effectiveness of the washing in any milking plant. Each SANIVAC is manufactured and individually tested under strict factory conditions to meet ISO Standards.
5030004_2023.06_EN Original instructions 6 INSTALLATION This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
− slowly screwing it to decrease the washing vacuum NOTE SANIVAC does not affect the milking vacuum level in any way. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
The user retains responsibility for correct installation and maintenance. Please contact your local milkrite | InterPuls dealer or sales representative for assistance if required. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
5030004_2023.06_EN Original instructions 8 SPARE PARTS DIAGRAM ef. 5030029 2023.04 This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
- Check the quality of the power Device not working Electrical fault cables (Sanivac and Top-Wash) - Check that the Top-Wash parameters are correctly set. This manual is the property of InterPuls S.p.A. - any copying, even partial, is strictly prohibited.
Page 14
| InterPuls | Albinea | Via F. Maritano 11 | 42020 | Reggio Emilia | Italy | T +39 0522347511 | F +39 0522 348516 | Sales.Albinea@milkrite-interpuls.com | www.milkrite-interpuls.com...
Need help?
Do you have a question about the milkrite Sanivac and is the answer not in the manual?
Questions and answers