19-PIN CONNECTOR ELECTRICAL CONNECTIONS
INPUT 2 CONNECTIONS USING EXTERNAL POWER

5.9 OUTPUTS

Three opto-coupled general purpose outputs are available on the 25-pin connector. The
meaning of the three outputs can be defined by the user. They are typically used either to
signal the data collection result or to control an external lighting system.
The pinout is the following:
Pin
8
22
11
12
16
17
The electrical features of the three outputs are the following:
× I
P
= V
D
Out
By default, Output 1 is associated with the Partial Read and No Read events, which activates
when the code(s) signaled by the external trigger are not decoded, and Output 2 is
associated with the Complete Read event, which activates when all the selected codes are
correctly decoded. Output 3, by default, is not associated with any event.
Matrix-2000™
6
I2A
V
~
CC
-
+
10
I2B
~
Figure 82 - Input PNP Using External Power
Matrix-2000™
6
I2A
V
~
CC
-
+
10
I2B
~
Figure 83 - Input NPN Using External Power
Name
Function
O1+
Configurable digital output 1 - positive pin
O1-
Configurable digital output 1 - negative pin
O2+
Configurable digital output 2 - positive pin
O2-
Configurable digital output 2 - negative pin
O3+
Configurable digital output 3 - positive pin
O3-
Configurable digital output 3 - negative pin
OUTPUT
I
Load
Open
0 mA
Closed
10 mA
= 170 mW Max.
oLoad
Vext 30 Vdc max.
INPUT DEVICE
V
I
in
Vext 30 Vdc max.
INPUT DEVICE
V
V
Out
30 Vdc Max
1.8 Vdc Max