TROUBLESHOOTING
Problem
One Shot or Phase Mode
using serial trigger source:
the "TRIGGER" LED is not
blinking.
Phase Mode:
the "TRIGGER" LED is
correctly blinking but no image
is displayed in VisiSet™
Calibration Tool window.
Continuous Mode:
the "TRIGGER" LED is not
blinking.
Any Operating Mode:
the "TRIGGER" LED is
correctly blinking but no result
is transmitted by the reader at
the end of the reading phase
collection.
Image not clear:
Image focused but not
decoded:
Reading:
the reader always transmits
the No Read Message
Communication:
reader is not transmitting
anything to the host.
Communication:
data transferred to the host
TROUBLESHOOTING GUIDE
Suggestion
In the Operating Mode folder check the settings for
Reading Phase-ON, Acquisition Trigger and
Reading Phase-OFF parameters.
Are the COM port parameters (Baud Rate, Parity, Data
Bits, Stop Bits, Handshake) correctly assigned?
In the communication folder, check the settings of
Reading Phase-ON String, Acquisition Trigger
String and Reading Phase-OFF String parameters.
Is the serial trigger source correctly connected?
Is the Phase frequency lower than the maximum frame
rate?
Verify the correct software configuration settings.
In the Data Collection folder check the settings for the
CODE COLLECTION, DATA FORMAT and
STATISTICS parameter groups.
verify the Focus procedure
verify the Calibrate Image Density prodcedure.
Perform the Rapid Configuration procedure in chapter 1.
Position the reader as described in par. 3.3, par. 7.1
and through the VisiSet™ Calibration Tool:
Tune the ACQUISITION TRIGGER DELAY, if the
moving code is out of the reader field of view;
Set the Continuous Operating Mode if no external
trigger source is available;
Tune the IMAGE ACQUISITION SETTING to
improve the code image quality;
Check the parameter setting in Decoding,
2D Codes, 1D Codes, and Postal Codes folders;
View the full resolution code image to check the
printing or marking quality.
Is the serial cable wiring correct?
If using CBX, be sure the RS485 termination switch is
OFF.
Are the host serial port settings the same as the reader
serial port settings?
In VisiSet™ Digital I/O folder, "COM" LED can be
configured to indicate MAIN COM port TX or MAIN
COM port RX.
Are the host serial port settings the same as the reader
serial port settings?