Rs485 Full-Duplex Interface - Datalogic Compact 2D Reader Matrix-2000 Reference Manual

Datalogic scanning compact 2d reader reference manual
Hide thumbs Also See for Compact 2D Reader Matrix-2000:
Table of Contents

Advertisement

19-PIN CONNECTOR ELECTRICAL CONNECTIONS

5.5.2 RS485 Full-Duplex Interface

The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication
protocols in point-to-point connections over longer distances (max 1200 m / 3940 ft) than
those acceptable for RS232 communications or in electrically noisy environments.
The following pins of the 25-pin connector are used for RS485 full-duplex communication:
Pin
2
4
3
5
7
Chassis
Earth Ground
For applications that do not use RX485 signals, do not leave these lines
floating but connect them to GND_ISO as shown below.
NOTE
Chassis
Earth Ground
Figure 68 - RS485 Full-duplex Connections using Only TX Signals
Name
Function
TX+
RS485 Transmit Data (+)
TX-
RS485 Transmit Data (-)
RX+
RS485 Receive Data (+)
RX-
RS485 Receive Data (-)
GND_ISO
Main opto-isolated reference ground
MATRIX
2
TX+
4
TX-
3
RX+
5
RX-
7
GND_ISO
1
SHIELD
Figure 67 - RS485 Full-duplex Connections
MATRIX
2
TX+
4
TX-
3
RX+
5
RX-
7
GND_ISO
1
SHIELD
USER INTERFACE
+
RX485
-
+
TX485
-
Reference Ground
Earth Ground
USER INTERFACE
+
RX485
-
Reference Ground
Earth Ground
5
47

Hide quick links:

Advertisement

Table of Contents
loading