External Lighting Systems - Datalogic Compact 2D Reader Matrix-2000 Reference Manual

Datalogic scanning compact 2d reader reference manual
Hide thumbs Also See for Compact 2D Reader Matrix-2000:
Table of Contents

Advertisement

CBX ELECTRICAL CONNECTIONS

4.6 EXTERNAL LIGHTING SYSTEMS

If an External Illuminator is used, it can be powered from the CBX connection box. It must be
connected to the Vdc and GND terminal clamps.
Power is available directly to the Illuminator, independently from the Power
Supply Switch inside the CBX.
CAUTION
In the case of the LT-100, LT-200 or LT-300 illuminators, one of the available digital outputs
must be connected as the control signal. In VisiSet™, configure the Output Line Function
parameter to "External Lighting System" and the Matrix Output x External Lighting System
Mode parameter to "Triggered".
Below is a table summarizing the various External Illuminator wiring and power requirements:
Illuminator
Wire Color
LT-100
Red
LT-200
Black
Blue
White
LT-300
Brown
Black
Yellow/Green
Blue
White
LT-210, LT-314,
White
LT-316, LT-410
Black
LT-510, LT-511
Shield
Control Signal for
LT-100, LT-200 or
LT-300 illuminators
Power to External
Illuminator
Figure 60 – External Lighting System Connections
CBX/Matrix Signal
Vdc
GND
O1- or O2-
O1+ or O2+
Vdc
GND
Earth
O1- or O2-
O1+ or O2+
Vdc
GND
Earth
Meaning
10 to 30 Vdc
Ground
Control Signal -
Control Signal +
10 to 30 Vdc
Ground
Shield/Earth Ground
Control Signal -
Control Signal +
24 Vdc
Ground
Shield/Earth Ground
4
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents