Outputs - Datalogic Compact 2D Reader Matrix-2000 Reference Manual

Datalogic scanning compact 2d reader reference manual
Hide thumbs Also See for Compact 2D Reader Matrix-2000:
Table of Contents

Advertisement

CBX ELECTRICAL CONNECTIONS

4.5 OUTPUTS

Thee optocoupled general purpose outputs are available. The meaning of the three outputs
can be defined by the user. They are typically used either to signal the data collection result
or to control an external lighting system.
CBX100/500
+V
O1+
O1-
O2+
O2-
O3+
O3-
-V
The electrical features of the three outputs are the following:
V
= 30 Vdc max.
CE
I
= 40 mA continuous max.; 130 mA pulsed max.
CE
V
CE saturation
P
= 80 mW Max. @ 45 °C ambient temp.
D
By default, Output 1 is associated with the Partial Read and No Read events, which activates
when the code(s) signaled by the external trigger are not decoded, and Output 2 is
associated with the Complete Read event, which activates when all the selected codes are
correctly decoded. Output 3, by default, is not associated with any event.
The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the two. Refer to
the Digital I/O folder in the VisiSet™ Help On Line for further details.
Figure 55 - NPN Input 2 Using External Power
Function
Power Source - Outputs
Output 1 +
Output 1 -
Output 2 +
Output 2 -
Output 3 +
Output 3 -
Power Reference Outputs
= 1 Vdc max. @ 10 mA
Input Device
Pulled up to External
Input Device Power
Input
Signal
4