USER MANUAL ECO Hybrid Inverter SNA 3000-6000W WPV Where sun shined Power always on Monitor APP Download Android Version: SNA-EN-UM-2.0-00 PN:092.20024AA LUX POWER TECHNOLOGY CO., LTD www.luxpowertek.com info@luxpowertek.com...
Table Of Contents 3. Working Modes Information on this Manual Validity 3.1 Offgrid modes introduction Scope 3.2 Working modes related setting description Target Group 3.3 Working as a hybrid inverter. Related setting 4. LCD Display and settings Safety Instructions 4.1 LED Display 1.
Integrated with 2 MPPT solar charge controllers, MPPT ranges 120V~385V CAUTION-To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries and Rated power SNA5000WPV/5KW, SNA6000WPV/6KW, power factor 1 lithium batteries, other types of batteries may burst, causing personal injury and damage.
1.3 Packing List 1.2 Interface of the inverter Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items in the package: LCD display Expansion Screw Wi-Fi Module X1 Cross Head Soft Magnetic Function buttons...
1. Battery connection: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. The recommend battery capacity is 150AH-200AH, the recommended spec of DC breaker is SNA5000WPV 150A/80V, SNA6000WPV 200A/80V. Recommended battery cable and terminal size:...
3. Connect all battery packs as units requires. It's suggested to connect at least 200Ah capacity battery The ambient temperature should be between 0°C and 55°C to ensure optimal operation. for SNA5000WPV/ 6000WPV. 4. Insert the ring terminal of battery cable flatly into battery connector of inverter and make sure the bolts The recommended installation position is to be adhered to the wall vertically.
Page 7
2.4 CT Please refer to the connection diagram for the correct positions of Grid CT and clamp the CT on the wires at the service entry point in the main service panel. The arrow on the CT is pointing to the To measure the power imported from and exported to the grid, a pair of Cts must be installed at the inverter.(*** Incorrectly install CT will cause The Display to show incorrect information and features of the inverter will not function correctly) If the CT is in a wrong direction, there is an option you can...
2.5 AC Input/Output Connection 2.6 PV Connection Please follow below steps to implement PV module connection: CAUTION!! 1. Remove insulation sleeve 10 mm for positive and negative conductors. - There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and 2.
All lux units can work with generator: 2.9 Parallel function Users can connect the generator output to ECO hybrid inverters. GEN input terminal. SNA series inverter support up to 16 units to composed single phase parallel system or three phase The generator will be automatically started when battery voltage is lower than the cut-off value or there is parallel system, for parallel system setup...
Page 10
Step2. Please put the CAN communication PIN to on status for the first and the end inverter No.n No.1 No.2 No.n-1 Parallel Parallel Parallel Parallel Parallel line1 Parallel line2 Parallel line(n-1 to n) Parallel line(n to 1) The max parallel quantity is 10, so 2<n<10 Step3.
2.10 Power and EPS ON/OFF 1.When the EPS key off, the inverter charge the battery only PV Charge 2.When the battery is power off, the PV can wake up the battery P1-485B P2-485A MPPT485/CT WIFI automatically P4-CANH P5-CANL Li-ion CAN/RS485 Dry Port GEN No2COM2Nc2No1 COM1 N c1 PV charge the battery and...
3.3 Working as a hybrid inverter. Related settings 3.3.1. SNA series can work as traditional off grid inverter or as a hybrid inverter. When disable PV&AC take load Jointly, it will work as a traditional off grid inverter, otherwise it will work as a hybrid working as a traditional off grid inverter.
4.2 LCD Display According to Time: During the setting time, system will use AC to charge the battery until battery full and battery will not discharge during the setting time. According to Battery Voltage: During the setting voltage, system will use AC to charge the battery if battery voltage is lower than AC Charge Start Battery Voltage and will stop when Voltage is higher than AC Charge End Battery Voltage.
4.3 Inverter Status Display 4.4 LCD Settings Normal status, running status 40 Warning Status, warning 29 There are four buttons on the LCD. Step for setting by the display: Step1: After touch Enter button for about 2 seconds, the unit will enter setting mode. The setting icon and index will flashing.
Page 15
Run with No Battery: Totoal charge current MODEL: SNA5000WPV Step1:Choose battery type first, when no flashing, (Iac+Ipv)setting select Enter to choose Run with No battery Setting range :0A~110A Default: 110A AC charge current setting: For Lead Acid: Setting range :0A~110A...
Page 16
Cut off Voltage (Only in Lead-acid or SOC, depend battery type) SOC: 0-OnGrid EOD SOC on TEOd Default: 15% MODEL: SNA5000WPV Setting range: VOLT: Cut off Volt-58V Default: 42V Totoal discharge current setting Setting range :0A~110A Default: 110A Eod:...
Page 17
AC Charge function: AC charge setting Setting range: (The setting process 1.DIS: AC charge disable; Setting Range: must enable the AC 2.TIM: According to time; Feed-In Disable (default) charging function, 3.VOL: According to battery voltage; confirm the full 4.SOC: According to battery soc; Feed-In battery SOC value, (Touch “Enter”...
Page 18
Error Record ->Record Index ->>Record Msg: Setting Range: (Year: Month:Day; PV Off Grid Enable (default) Hour: Min:Sec; Error code) PV Off Grid Error/Alarm enable/disable Record PV Off Grid Disable Alarm Record->Record Index->>Record Msg: (Year:Month:Day; Hour:Min:Sec; Alarm code) Setting Range: External Grid CT Green Function Disable (Latest Version Only) (default)
Page 19
5. Monitor System for ECO Hybrid inverter Users can use wifi dongle / WLAN dongle / 4G dongle (Avaiblable from 2021 March for some countries) to monitor the energy storage system, The monitor website is: server.luxpowertek.com Generator charge setting The APP is also available in the google play and apple APP store(Scan two code bar to download the APP). ->charge control type Please download the introduction of guidance by website: https://www.luxpowertek.com/download/ Setting Range:...
Table 1 MPPT Mode Specifications Low DC Warning Warning Voltage @load < 20% -1.2V 20% ≤ load < 50% Voltage(Lead Acid) INVERTER MODEL SNA5000WPV SNA6000WPV Warning Voltage @load < 20% -3.6V load ≥ 50% Max. PV Array Power(W) 8000(4000/4000) Low DC Warning Voltage@Different load+2V...
Page 21
Table 3 Line Mode Specifications Table 4 Generator Mode Specifications INVERTER MODEL SNA5000WPV SNA6000WPV INVERTER MODEL SNA5000WPV SNA6000WPV Input Voltage Wavefor Sinusoidal(utility or generator) Rated GEN Voltage(V) 230Vac 50/60 Nominal Input Voltage(V) Rated GEN Frequency(Hz) 170Vac±7V(UPS); 90Vac±7V(Appliances) Low Loss Voltage Rated GEN Input Current(A) 180Vac±7V(UPS);...
7. Trouble Shooting & Error List The failures mainly divided into 5 categories, for each category, the behavior is different: Description Trouble shooting Code Code Description Trouble shooting Restart inverter, if the error still exist, Check if you have choose the right battery brand E000 Internal communication fault1 W000...
Need help?
Do you have a question about the SNA5000WPV and is the answer not in the manual?
Questions and answers