Error Message and Recovery Procedures
Error Message GIGASTACK-6-LOOP_DETECTED
Explanation
master loop breaker. Link 2 of this GigaStack GBIC is disabled to break the loop.
Recommended Action
Error Message GIGASTACK-6-NO_LOOP_DETECT
Explanation
links on a GigaStack GBIC. Either the neighboring switch does not support the GigaStack
loop-breaking algorithm, or the link between the two GigaStack GBICs is broken. Under this
condition, a GigaStack loop topology is not automatically detected, and the connectivity between
switches in the stack could be lost.
Recommended Action
running on all switches in the stack. Verify that the GigaStack GBICs involved are functioning.
Error Message GIGASTACK-6-LOOP_BROKEN: Link loss is detected in the Gigastack
loop\nLink 2 of the Gigastack GBIC in [chars] is re-enabled.
Explanation
loop breaker is re-enabled to replace the broken link
Recommended Action
Error Message GIGASTACK-6-LOOP_DETECTED: Gigastack GBIC in [chars] is selected as
Master Loop Breaker. \nLink 2 of the Gigastack GBIC is disabled to break the loop.
Explanation
loop breaker. Link 2 of this GigaStack GBIC is disabled to break the loop.
Recommended Action

HW_MEMORY Messages

This section contains the hardware memory error messages.
Error Message HW_MEMORY-3-READMEMFAIL: \n[chars]: Failed to read [chars] from ASIC.
Explanation
Recommended Action
Copy the error message exactly as it appears on the console or in the system log. Enter the show
tech-support command to gather data that might provide information to determine the nature of the
error. If you cannot determine the nature of the error from the error message text or from the show
tech-support output, contact your Cisco technical support representative, and provide the
representative with the gathered information.
Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
A-18
A loop has been detected in the GigaStack, and this GigaStack GBIC is selected as the
No action is required.
No acknowledgement for GigaStack loop detection request is received from one of the
If loop topology is used in the GigaStack, make sure that the latest software is
A loop formed by GigaStack modules is broken because of link loss. Link 2 of the master
No action is required.
A loop is detected in the GigaStack, and this GigaStack GBIC is selected as the master
No action is required.
Failed to read memory from hardware.
If this is happening with all features on the switch, this is a hardware failure.
Appendix A
System Messages
78-6511-08