Appendix A
System Messages
Error Message CMP-5-MGMT_VLAN_CHNG: The management vlan has been changed to [dec]
Explanation
Recommended Action

CPU_NET Message

This section contains the CPU network interface error message.
Error Message CPU_NET-0-QUEUE_STUCK: The interface between the CPU and the switch
has\nbecome stuck. The switch must now reset to clear this condition\n.Retrieval
queue [dec].\n
Explanation
Recommended Action

ENVIRONMENT Messages

This section contains the environment error messages.
Error Message ENVIRONMENT-2-FAN_FAULT: System Fault: FAN FAULT is detected.
Explanation
on the Catalyst 3524-PWR XL switch.
Recommended Action
to check if a fan on the switch has failed. The Catalyst 3524-PWR XL switch can operate normally
with one failed fan. Replace the switch at your convenience.
Error Message ENVIRONMENT-2-OVER_TEMP: System Fault:OVER TEMPERATURE condition is
detected.
Explanation
available only on the Catalyst 3524-PWR XL switch.
Recommended Action
it does:
78-6511-08
The management VLAN has been changed.
No action is required.
The CPU can no longer communicate with the network.
Reload the system.
This message means that an internal fan fault is detected. This message is available only
Either check the switch itself, or use the show env privileged EXEC command
This message means that an overtemperature condition is detected. This message is
Use the show env command to check if an overtemperature condition exists. If
Place the switch in an environment that is within 32 to 113°F (0 to 45°C).
Make sure fan intake and exhaust areas are clear.
If a multiple-fan failure is causing the switch to overheat, replace the switch.
Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
Error Message and Recovery Procedures
A-9