MacroAir Technologies LINCOLN STREET Installation Manual

MacroAir Technologies LINCOLN STREET Installation Manual

Residential fan

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LINCOLN STREET and is the answer not in the manual?

Questions and answers

Summary of Contents for MacroAir Technologies LINCOLN STREET

  • Page 3: Table Of Contents

    Warranty ......21 © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 4: Installation Overview

    ATTENTION: Mounting on an Inclined Ceiling. The maximum angle (or slope) of the ceiling cannot be greater than 20 degrees (or 4:12 pitch). © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 5: Fan Dimensions, Fan Components

    Installation Overview LINCOLN STREET Fan Dimensions The dimensions listed above are applicable to all MacroAir Lincoln Street fans using a 6” drop tube. Add 6” to drop dimensions provided when using the 12” drop tube. Fan Components View of Assembled Fan...
  • Page 6: Mounts And Components

    (1) Clevis Pin (1) Hairpin Cotter Pin Fan Blades (6) Blades Images are not to scale © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 7: Tools Required

    Installation Overview LINCOLN STREET Tools Required Images are not to scale © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 8: Ceiling Fan Junction Box

    (typically at the building main breaker box) and is secured against accidentally being powered on during installation. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 9: Installing The Fan

    Installing the Fan LINCOLN STREET Unboxing the Fan Location of fan components in the packaging container. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 10: Securing The Drop Tube To The Motor Unit

    Note: The Swivel Ball will come previously mounted to the top of the 6” Drop Tube. It is not necessary to remove the Swivel Ball unless transferring it to the 12” Drop Tube. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 11 Motor Unit to more securely affix the drop tube in the motor. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 12: Assembling The Top Of The Drop Tube

    Swivel Ball must be removed from the 6” tube and then mounted onto the 12” tube. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 13: Securing The Swivel Ball To 12" Drop Tube

    4) Tighten the Pinching Screw through the threaded hole of the Swivel Ball and against the wall of the Drop Tube until the Drop Tube is held firm. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 14: Ceiling Fan Junction Box And Pwr Wires

    (typically at the building main breaker box) and is secured against accidentally being powered on during installation. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 15: Ceiling Fan Mnting Bracket & Pwr Wires

    (unjacketed) copper wire. The illustrations in this manual depict the ground wire with a green jacket to more easily differentiate it from other wires in the illustrations. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 16: Hanging The Ceiling Fan

    Mounting Bracket. This prevents the assembly from spinning when the fan is operating. Refer to the following pages for additional instructions on hanging the fan. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 17 Note: The Ceiling Mounting Bracket is not shown mounted on the ceiling fan junction box in the above view for clarity. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 18: Connecting To 110-120Vac Power

    Bowl Cap and Ceiling Mounting Bracket in the Hardware Kit (ref instruction 2 page 9 of this manual). © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 19: Installing Fan Blades

    2) Using a 5/32 Hex Key remove four (4) of the twelve (12) blade mounting bolts from the motor unit. Two (2) on one side and two (2) directly opposite. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 20: Attaching The Fan Blades

    4) After all six (6) fan blades are mounted, reinstall the bottom cover using a 5/32 Hex Key and the mounting screws previously removed. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 21: Handheld Remote

    LIGHT ON / OFF (IF INSTALLED ON FAN) BATTERY SIZE: CR2032 (NOT INSTALLED) Images are not to scale © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 22: Fan Settings

    5) The remote is now paired and drive calibrated. Fan speed can now be selected as normal. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...
  • Page 23: Maintenance

    Reverse Operation: The beauty of MacroAir Lincoln Street fans is that they are built to run in forward and reverse mode. However, changing the direction of your fan can put initial stress on the fan if it has not been properly checked.
  • Page 24: Warranty

    1 "Standard Electrical" means any common electrical component that is utilized across more than one fan line will assume the higher warranty period. 2 "Operate properly" applies only to mechanical, electrical, and structural systems of the Product. © 2021 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com LINCOLN STREET FAN INSTALLATION MANUAL 90-30092-00 Rev A-01 Date: 060424...

Table of Contents