MacroAir Technologies X Series Operation Manual

MacroAir Technologies X Series Operation Manual

Local override remote

Advertisement

Operation Manual
MacroAir Local
Override Remote

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MacroAir Technologies X Series

  • Page 1 Operation Manual MacroAir Local Override Remote...
  • Page 3: Table Of Contents

    Three Phase (High Voltage) ...... 10 Operation Basic Operation ......... 11 Appendices Warranty ..........12 Technical Support ........13 © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com Local Override Remote Operation Manual 90-30059-00 Rev A-01 Date: 060120...
  • Page 4: Caution & Safety

    ATTENTION: Qualified Technicians. All electrical troubleshooting and repair must be done by a qualified technician and meet all applicable codes. REFER TO FAN INSTALLATION MANUAL(S) FOR FURTHER MAINTENANCE INFORMATION. © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com...
  • Page 5: Remote Enclosure

    Introduction Remote Enclosure Control Panel Enclosure Images are not to scale © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com Local Override Remote Operation Manual 90-30059-00 Rev A-01 Date: 060120...
  • Page 6: Remote Panel Overview

    Wiring the Fan Remote Panel Overview Control Panel Overview 1 Phase (Low Voltage) © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com Local Override Remote Operation Manual 90-30059-00 Rev A-01 Date: 060120...
  • Page 7 Wiring the Fan Control Panel Overview, cont. 3 Phase (Low Voltage) 3 Phase (High Voltage) © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com Local Override Remote Operation Manual 90-30059-00 Rev A-01 Date: 060120...
  • Page 8 MacroAir. 7. Connect CAT5e ntroller. This control panel overview supersedes and replaces that found in your fan Operation Manual. © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com Local Override Remote Operation Manual 90-30059-00 Rev A-01 Date: 060120...
  • Page 9: Remote Panel Schematic

    Wiring Diagrams Remote Panel Schematic © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com Local Override Remote Operation Manual 90-30059-00 Rev A-01 Date: 060120...
  • Page 10: Control Panel Schematic Single Phase (Low Voltage)

    Wiring Diagrams Control Panel Schematic - Single Phase (Low Voltage) This control panel schematic supersedes and replaces that found in your fan Operation Manual. © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com Local Override Remote Operation Manual 90-30059-00 Rev A-01 Date: 060120...
  • Page 11: Control Panel Schematic Three Phase (Low Voltage)

    Wiring Diagrams Control Panel Schematic -Three Phase (Low Voltage) This control panel schematic supersedes and replaces that found in your fan Operation Manual. © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com Local Override Remote Operation Manual 90-30059-00 Rev A-01 Date: 060120...
  • Page 12: Control Panel Schematic Three Phase (High Voltage)

    Wiring Diagrams Control Panel Schematic -Three Phase (High Voltage) This control panel schematic supersedes and replaces that found in your fan Operation Manual. © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com Local Override Remote Operation Manual 90-30059-00 Rev A-01 Date: 060120...
  • Page 13: Basic Operation

    FAN: Refer to the fan manual for information regarding the fan. REMOTE FAIL: If the Local Override Remote fails to operate the fan, check the wiring, and/or check the VFD for faults. © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com...
  • Page 14: Warranty

    START DATE OF WARRANTY COVERAGE Warranty period for X Series and AVD fans with 50,000 operating hours covers the Motor, Electrical Controls, and Remote for 50,000 hours of run time. For all other fans, the warranty period begins fifteen (15) days following shipment of the product, or on the date the product is installed (not to exceed sixty (60) days Customer receives the product), whichever date is later.
  • Page 15: Technical Support

    866-668-3247 option 2 Website: www.macroairfans.com/support For Installation assistance, application questions, technical support, and any other inquiries, please contact our Technical Support team at (866) 668-3247. © 2020 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com Local Override Remote Operation Manual 90-30059-00 Rev A-01 Date: 060120...
  • Page 16 794 South Allen Street San Bernardino, CA 92408 (866) 668-3247 Macroairfans.com...

Table of Contents