Functional Overview
The show environment last command retrieves and displays the NVRAM log, which shows the reason
for the last system shutdown (if the shutdown was related to voltage or temperature) and the
environmental status at that time. Air temperature is measured and displayed, and the DC voltage
supplied by the power supply is also displayed.
Following is sample output of the show environment last command:
Router# show environment last
Temperature readings:
chassis inlet previously measured at 27C/80F
chassis outlet 1 previously measured at 31C/87F
chassis outlet 2 previously measured at 37C/98F
chassis outlet 3 previously measured at 45C/113F
Voltage readings:
+3.45 V previously measured at +3.51 V
+5.2 V
+12.2 V previously measured at +12.42 V
-12.2 V previously measured at -12.14 V
Reason for last shutdown:
power supply
The show environment table command displays the temperature and voltage thresholds for each
temperature sensor and for each monitored status level, which are related to those thresholds listed in
Table 1-10
Following is sample output of the show environment table command for a Cisco 7206 that has an
installed NPE-150:
Router# show environment table
Sample Point
chassis inlet
chassis outlet 1
chassis outlet 2
chassis outlet 3
+3.45 V
+5.15 V
+12.15 V
-11.95 V
System shutdown for chassis outlet 1 58C/136F
System shutdown for chassis outlet 3 70C/158F
Following is sample output of the show environment table command for a Cisco 7206 that has an
installed NPE-100 or NPE-200:
Router# show environment table
Sample Point
chassis inlet
chassis outlet 1
chassis outlet 2
chassis outlet 3
+3.45 V
+5.15 V
+12.15 V
-11.95 V
System shutdown for chassis outlet 1 58C/136F
System shutdown for chassis outlet 3 65C/149F
Cisco 7206 Installation and Configuration Guide
1-34
previously measured at +5.19 V
and
Table
1-11. The display also lists the shutdown threshold for the system.
LowCritical
+3.26
+4.86
+11.39
-9.52
LowCritical
+3.26
+4.86
+11.39
-9.52
LowWarning
HighWarning HighCritical
40C/104F
43C/109F
75C/167F
55C/131F
+3.34
+3.55
+4.99
+5.31
+11.67
+12.62
-10.73
-13.16
LowWarning
HighWarning
40C/104F
43C/109F
75C/167F
50C/122F
+3.34
+3.55
+4.99
+5.31
+11.67
+12.62
-10.73
-13.16
Chapter 1
Product Overview
50C/122F
53C/127F
75C/167F
65C/149F
+3.63
+5.43
+12.91
-14.38
HighCritical
50C/122F
53C/127F
75C/167F
60C/140F
+3.63
+5.43
+12.91
-14.38
OL-5102-02