2.6 Modulators
The Nyx three modulators have identical controls and range times:
Rise: 1ms to 5sec
Fall:10ms to 15sec
GATE
HOLD
Don't care
OFF
ON
Don't care
Don't care
OFF
ON
LOW
ON
HIGH
When the Modulators are into LFO state,
their speed and wave shape depend on the RISE and FALL settings
2.7 REVERB
NYX is equipped with a digital Reverb algorithm.
1.TIME: Sets the Pre-delay
brightness of the Reverb. The higher the Time the
brighter the Reverb sound.
2. DECAY: Reverb's decay time. At max it's infinite.
3. MIX: Blends between dry and wet Reverb sound.
2.8 Routing
There are 3 rotary switches that will determine how NYX will sound and behave.
WARNING!
In some cases and combinations,
you might not get sound at all or the required result.
1. VCO ROUTING
NOR: Both Oscillators are being routed to Filter 1.
SPLIT: Oscillator 1 is routed to Filter 1 and Oscillator
2 is routed to Filter 2.
HALF: Both Oscillators are being routed to Filter 2.
VCA: Both Oscillators are being
VCA, bypassing the Filters.
LFO
RESULT
OFF
ATTACK/DECAY
OFF
ATTACK/DECAY
LFO
ON
LFO
ON
MAX STATE
ON
Time.
This will also affect the
routed
directly to
REVERB
1
2
DECAY
ROUTING
VCO
nor
LPF
split
HPF
half
EVEn
vcA
odd
3
VCF