Install the hub stack in a site free from strong
electromagnetic field generators (such as motors), vibration,
dust, and direct exposure to sunlight.
Leave at least 10cm of space at the front and rear of the hub
for ventilation.
Install the hub on a sturdy, level surface that can support its
weight, or in an EIA standard-size equipment rack. For
information on rack installation, see the next section, Rack
Mounting.
When installing the hub stack on a level surface, attach the
rubber feet to the bottom of each device.
cushion the hub and protect the hub case from scratching.

100Base-FX Module Installation

The installation procedure for each module is the same.
Additional information about each module is provided below.
To install any of the modules: (Includes SC or ST type
connectors)
1. Locate the module slot in the switch's rear panel.
2. Using a screwdriver, undo t he two screws and remove
the dust cover on the module slot.
3. Holding the module component-side up and connector-
side in, gently slide the module along the guides and seat
it in the internal connector.
4. Using a screwdriver, replace the two screws and tighten
until snug.