Node Controller Hardware User Manual Catalog Numbers 700-0871-00, 700-1573-00, 700-1842-00, MMI-NC-ENET-01, MMI-NC-SER08-01 User Manual Original Instructions...
Page 2
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
Label Identification and Location ..........................18 Electrical Hazards.................................21 Recycling and Disposal Information ......................... 22 Node Controllers..............................22 Packaging................................22 3 Node Controller Overview Node Controller Description............................23 Node Controller Types............................23 NC-S Node Controller........................... 23 Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 4
NC LITE................................... 55 AC Power Option ............................55 DC Power Option............................55 Ethernet Switch with Power over Ethernet Injector..................58 AC Power Option ............................58 DC Power Option............................58 Site Requirements ............................... 59 Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 6
Unpacking and Inspection..........................95 Network Connections ............................95 Motor Connections............................... 95 Configuration............................... 95 Maintenance................................95 B History of Changes Rev. A..................................97 Rev. B ..................................97 Rev. C ..................................97 Rev. D ..................................97 Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
ATTENTION: Caution indicates a hazardous situation, which if not avoided, could result in minor or moderate injury. NOTICE ATTENTION: Notice indicates practices that are not related to personal injury that could result in equipment or property damage. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
MagneMotion Virtual Scope Utility User Manual, publication This manual explains how to install and use the MagneMotion Virtual Scope utility. This utility MMI-UM011 provides real-time feedback of the change in Linear Synchronous Motor performance parameters. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Restoring from Backup Files Damaged files can be restored by copying the backup files into the appropriate locations. Transport System Limits For transport system limits information, see the MagneMotion® Node Controller Interface User Manual, publication MMI-UM001. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Vehicles with magnet arrays. • Paths and nodes. • User-supplied host controller. Transport System Components Overview This section identifies the components of a transport system as shown in Figure 1-1 and described after the figure Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 12
• Vehicle with Magnet Array – Carries a payload through the transport system as directed. The magnet array is mounted to the vehicle and interacts with the motors, which moves each vehicle independently. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
NCHost TCP Interface Utility System Testing MagneMotion Info and Config Service (MICS_motor_data.xml) track_file.mmtrk demo_script.txt Motors MagneMotion System Configurator node_configuration.xml MICS_motor_data.xml MagneMotion NC File Retrieval Tool Commissioning Tool Figure 1-2: Simplified View of Transport System Software Organization Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
See the MagneMotion Host Controller TCP/IP Communication Protocol User Manual, publication or the MagneMotion Host Controller EtherNet/IP MMI-UM003 Communication Protocol User Manual, publication MMI-UM004. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
• EMC Directive • 61010-1 NOTICE ATTENTION: It is the responsibility of the end user/third party integrator to make sure that the installed node controllers comply with the appropriate facility, local, and national regulations. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Ergonomic hazards can exist with certain installation or service operations that are related to the node controllers. Equipment Safety Guidelines The following safety considerations are provided to aid in the placement and use of the Rockwell Automation node controllers. •...
Table 2-3: Mandatory Action Symbol Identification Symbol Description ATTENTION: Lockout Required – Indicates that all power must be disconnected using a method that helps prevent accidental reconnection. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
The following tables list the labels that are affixed to the node controllers. The figure after each table shows the location of each label that is identified in the table. To replace a lost or damaged label, contact Rockwell Automation and reference its name.
Page 19
SN *XXNNXXNNN* SN *XXNNXXNNN* Product Information Label Qty: 1 Location: On the back of the NC-E Series B node controller 123456 Information Label Figure 2-2: Label Locations on the NC-E Series B Node Controller Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 20
Location: On the back of the NC-12 node controller MAC ID Label S/N:????????? Qty: 1 MAC: 1A-2B-3C-4D-5E-6F Location: On the back of the NC-12 node controller Information Label MAC ID Label Figure 2-3: Label Locations on the NC-12 Node Controller Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
ATTENTION: To avoid electric shock, do not open any node controller. Node controllers do not contain any user-serviceable parts. ATTENTION: Do not turn on electrical power to the node controllers until after connecting all other transport system components. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
The packaging for the node controllers contains the following materials. If the packaging is not being saved, it must be disposed of by following all facility, local, and national procedures for the disposal of packaging material: • Cardboard. • Polyethylene Foam. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Check the product label to see which series of node controller you have (see Figure 2-2). NC-E Series B node controllers are labeled with “SRS B”. For Series A specific information, see NC-E Series A Node Controller Specifications. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Motors that use Ethernet communication can use different network connection schemes depending on the application. When using Ethernet, all motors must be on the same LAN as the node controllers that own them. The motor user manual describes different motor network topologies and provides examples. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
• The use of Allen-Bradley® Stratix® Managed Ethernet Switches is recommended to deliver the required network performance. • Ethernet chains can consist of multiple paths (as defined in the transport system layout drawing). Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
The processor loading on the node controllers when using Ethernet to communicate with the motors has been determined based on the various use cases as shown in Table 3-1. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Figure 3-2: Digital I/O Equivalent Circuits Table 3-2: Digital I/O Power Requirements NC-E Digital Inputs (+V DC) +5…24V DC +5…35V DC Digital Outputs (DC) Digital outputs have a +5…35V DC 100mA sink current Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
E-stop Resistor * Digital I/O High Digital I/O Low Digital I/O Ground NC-E Series B Node Controller 24V DC Power Supply * Resistor to reduce current to less than 20 mA (as needed). Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Make sure that the connector blades are making direct contact with the wire and are not in contact with the insulation. Connector Release Connector Connector Release Connector Figure 3-3: Digital I/O Connections Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
NOTE: Motion cannot resume until the button is released and the host controller issues a Resume command to the paths associated with the E-stop. E-stop E-stop NC-12 Node Controller Digital In Digital In +3…24V DC Power Supply Figure 3-4: E-stop Wiring Diagram, Single Node Controller Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
3-6, is connected to a digital output on the host controller such that breaking the circuit activates the interlock. The interlock is cleared by taking the interlock signal High. In this configuration other digital I/O functions are not available. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 32
EMO (Emergency Off), which removes power to the transport system. NC-12 Node Controller Digital In User-installed Circuit Digital In +3…24V DC Power Supply Figure 3-6: Interlock Wiring Diagram Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
CO N SO LE N ET 0 N ET 1 N ET 2 [1.71] 43.5 NODE CONTROLLER-S [11.49] 291.9 Weight: 1.95 kg [4.3 lb] All Dimensions in Millimeters [Inches] Figure 4-1: NC-S Node Controller Mechanical Drawing Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 34
Ingress Protection Rating: Designed for IP20. See NC-S Node Controller on page 44 for the electrical specifications. Exposed Materials The node controller has unprotected openings and must not be installed in locations where harsh conditions exist. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Ingress Protection Rating: Designed for IP30. See NC-E Series B Node Controller on page 47 for the electrical specifications. Exposed Materials The node controller has unprotected openings and must not be installed in locations where harsh conditions exist. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Ingress Protection Rating: IP20. See NC-12 Node Controller on page 50 for the electrical specifications. Exposed Materials The node controller provides openings for airflow and must not be installed where harsh conditions exist. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Ingress Protection Rating: IP20. See NC-12 Node Controller on page 50 for the electrical specifications. Exposed Materials The node controller provides openings for airflow and must not be installed where harsh conditions exist. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Ingress Protection Rating: IP30. See NC LITE on page 55 for the electrical specifications. Exposed Materials The node controller has unprotected openings and must not be installed in locations where harsh conditions exist. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
ATTENTION: AC power must be disconnected before servicing. AC Power Cable The optional remote power supply for the NC-S node controller is supplied with a power cable. Contact Rockwell Automation for replacement cables. The AC power cable plugs directly into the power supply.
Page 45
POWER 24-48V DC ±10%, 10 W M12 Eurofast, 4-Pin, Plug Rockwell Automation recommends that the odd number connectors be used for upstream connections and the even number connectors be used for downstream connections. † Rockwell Automation requires grounding the NC-S through the chassis ground connection on the power connector.
Power Status Indicators Reset Power Ethernet Digital I/O Port Figure 4-12: NC-E Series B Node Controller Electrical Connections, Controls, and Indicators Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 48
6V…36V DC IN 6…36V DC, 40 W 3P pluggable connector with latch (V-, GND, V+) Rockwell Automation requires grounding the NC-E Series B through the chassis ground connection on the power connector. Table 4-8: NC-E Series B Node Controller Controls Label...
ATTENTION: AC power must be disconnected before servicing. AC Power Cable The optional remote power supply for the NC-12 node controller is supplied with a power cable. Contact Rockwell Automation for replacement cables. The AC power cable plugs directly into the power supply.
Page 51
M6 threaded stud IP67 rated mating connector is not required. † Rockwell Automation recommends that the odd number connectors be used for upstream connections and the even number connectors be used for downstream connections. ‡ Rockwell Automation requires grounding the NC-12 through the ground stud with a minimum of 14 AWG wire.
Page 52
† Ground M6 threaded stud Rockwell Automation recommends that the odd number connectors be used for upstream connections and the even number connectors be used for downstream connections. † Rockwell Automation requires grounding the NC-12 through the ground stud with a minimum of 14 AWG wire.
Page 54
16 outputs Input Output +3…24V DC +5…35V DC † — DC RTN Figure 3-2 on page 27 for the digital I/O equivalent circuits. † The GND pin is not used for the digital inputs. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
AC Power Cable The optional remote power supply for the NC LITE is supplied with a power cable. Contact Rockwell Automation for replacement cables. The AC power cable plugs directly into the power supply. The remote power supply and AC cable for the NC LITE is not required if Power over Ethernet is being used.
Page 56
Rockwell Automation requires grounding the NC LITE by mounting to a grounded surface. † Rockwell Automation recommends that the odd number (male) connectors be used for upstream connections and the even number (socket) connectors be used for downstream connections. Table 4-24: NC LITE Power Pinout Sleeve 2.0 mm Coax, Plug...
ATTENTION: AC power must be disconnected before servicing. AC Power Cable The Ethernet Switch with PoE power supply is supplied with a power cable. Contact Rockwell Automation for replacement cables. The AC power cable plugs directly into the power supply.
When operating in a high altitude environment with lower air pressure, the operating temperature range must be derated compared to that of sea level. Lighting, Site No special lighting is required for proper operation of the node controllers. Maintenance can require a user-supplied service lamp (for example, a flashlight). Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
NOTE: The exclusion zones that are shown are for the node controllers only. Additional exclusion zones may be required based on the design of the transport system. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
61; inspect and verify the contents against the shipping documents. Report any damage or missing items immediately to the shipper and to Rockwell Automation. One set of shipping documents is attached to the outside of the main shipping crate for easy access.
2. Clip the node controller onto the DIN rail in the appropriate location. Make sure that the service and exclusion zones are maintained. 3. Install cable management as required to secure the cables that are connected to the node controller. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 63
2. Locate the node controller as required and secure it with a minimum of two screws per mounting bracket. Make sure that the service and exclusion zones are maintained. 3. Install cable management as required to secure the cables that are connected to the node controller. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 64
Mounting NC-S Power Supplies Locate the power supply close to the node controller it is powering to minimize the length of all wiring. The power supply can be oriented in any direction required. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
3. Clip the node controller onto the DIN rail in the appropriate location. Make sure that the service and exclusion zones are maintained. 4. Install cable management as required to secure the cables that are connected to the node controller. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 66
3. Locate the node controller as required and secure it with four screws (two per mounting bracket) make sure that the service and exclusion zones are maintained. 4. Install cable management as required to secure the cables that are connected to the node controller. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Rack Mounting The NC-12 can be mounted in a standard 19 inch rack by attaching the optional 2U rack mounting brackets as shown in Figure 5-8. Figure 4-8 on page 41 for dimensions. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 68
Mounting NC-12 Power Supplies Locate the power supply close to the node controller it is powering to minimize the length of all wiring. The power supply can be oriented in any direction required. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
If the node controller is powered using the remote power supply (instead of using PoE), locate the power supply close to the node controller it is powering to minimize the length of all wiring. The power supply can be oriented in any direction required. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
3. Connect power to each NC-12: NOTICE ATTENTION: The NC-12 node controller does not support Power over Ethernet. Never connect these node controllers to a powered Ethernet network as damage to internal components can result. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Controller (optional) Uplink EtherNet/IP TCP/IP or ENet/IP SYNC IT (optional) Network Switch (No PoE) Network Switch (PoE) NC LITE NC LITE NC LITE NC-12 NC-E NC-S . . . Figure 5-10: Network Wiring Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 72
For NC LITE node controllers, connect the Ethernet cable to the LAN connector as shown in Figure 4-14. NOTICE ATTENTION: The NC LITE only supports Power over Ethernet. Never connect the NC LITE to a standard PoE network as damage to internal components can result. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
When connecting a DE-9 connector, tighten the mounting screws to 3 in•lb [0.34 N•m] – do not overtighten. When connecting a Nano-Mizer connector, tighten the connector shell finger tight only – do not overtighten. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
2. Connect a Cat5 or better Ethernet cable from the downstream connection on the motor to the upstream connection on the next motor in the chain. 3. Continue making motor-to-motor Ethernet connections until the last motor in the path is reached. 4. Create a MICS file to define the Ethernet motor connections. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
The Configuration File must then be uploaded to each node controller in the transport system before using the system. See the MagneMotion Node Controller Interface User Manual, publication MMI-UM001 for details. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Upgrades to the software can be uploaded through the network communications link. See the Upgrade Procedure in the Release Notes supplied with the software upgrade. NOTE: Only qualified personnel or personnel that are directed by Rockwell Automation should make alterations or changes to the software.
Node Controller, NC-12 Power Node Controller, NC LITE None — 6. If power-up was successful, the node controller is ready to accept commands. However, if the power-up sequence was unsuccessful, see Troubleshooting on page Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
6. Move vehicles individually or create a Demo Script for repetitive testing (see the MagneMotion NCHost TCP/IP Interface Utility User Manual, publication MMI-UM010). 7. Use the NCHost TCP Interface Utility to monitor transport system operation. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
8. Turn off the main power disconnect for the transport system. NOTE: This procedure only shuts down facilities to the motors, their subsystems, and the Host Controller. Any user equipment remains powered up. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 80
Installation This page intentionally left blank. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
This chapter provides maintenance schedules and procedures for the node controllers. Only trained, qualified personnel should attempt to perform maintenance or troubleshooting on the node controllers. Rockwell Automation provides training in the troubleshooting and repair of the transport systems and components.
ATTENTION: Only a qualified service representative can service the components of the transport system. Any attempt to open the transport system modules by anyone other than a qualified Rockwell Automation® service representative voids the warranty. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
NC-S it is necessary to upgrade all other node controllers in the system to the same software version. Upgrading to the NC-S may also require upgrading the motor software in all motors in the system. Table 6-6 identifies the minimum software versions that are required for proper operation of the NC-S node controller. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 84
From the host controller, issue a Reset command for all paths, once all paths have completed their reset issue a Startup command to all paths. Review the node controller log file to verify that the NC-S is operating properly. Start the host application to begin normal operation. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Follow all facility, local, and national procedures for the disposal of any hazardous materials. 4. When shipping individual components, remove all components that will be shipped (reverse the sequence to install the components) and see Shipping on page Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
4. Make sure that the container is properly labeled (This End Up, Caution – Heavy, and so forth) and all shipping documents are attached to the outside of the container. 5. When shipping, make sure that the RMA number is clearly visible on the outside of the box. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
RS-422 and some connections are made using Ethernet. This typically occurs when a node (for example, a Relay node) is being used to connect RS-422 motors to Ethernet motors. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Dimensions [4.72 W x 3.94 L x 2.19 H] ~95% @ 40 °C [104 °F] Relative Humidity: (noncondensing) Weight: 0.65 kg [1.43 lb] Power Dissipation: 40 W (max) All dimensions are millimeters [inches]. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 89
NOTE: The node controller has unprotected openings and must not be installed in locations where harsh conditions exist. Table A-3: Labels Used on the NC-E Node Controller Product Information Label Qty: 1 Location: On the back of the NC-E node controller Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
The NC-E Series A can be mounted to a DIN Rail by attaching the optional DIN rail mounting bracket as shown in Figure A-2. DIN Bracket M4 Screw (2X) Figure A-2: NC-E Node Controller DIN Rail Mounting Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
For connection of user-supplied terminal for setting the IP address (DE-9, Plug). Digital I/O: 4 optically isolated digital input bits and 4 optically isolated digital output bits (DA-26, Socket). Rockwell Automation requires grounding the NC-E through the chassis ground connection on the power connector. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Connecting with the power supply on can cause a short circuit at the connector, which can damage the power supply or any other equipment being powered by that power supply. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 94
External terminal DE-9, Plug 6V~36V DC IN 6…36V DC, 40 W 3P pluggable connector with latch (V-, GND, V+) Rockwell Automation requires grounding the NC-E through the chassis ground connection on the power connector. Table A-2: Controls Label Description Control Type Forced reset of node controller.
The maintenance information for Series A and Series B are the same. For additional information on preventive maintenance, transfer log files, troubleshooting, repair, and upgrading node controllers for the NC-E node controllers, see the respective heading Maintenance in the section starting on page Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 96
NC-E Series A Node Controller Specifications This page intentionally left blank. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Publication MMI-TD039 was added to of this document. Removed the following: • Figures reference chapter was removed. • Tables reference chapter was removed. • Glossary was removed. • Restricted parameters information was removed. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 98
Definition for setting up digital I/O on NC-E Series B, page • Additional node controller troubleshooting information, Table 6-3. • Reformatted document to RA standards. • Added MMI-RM003, MagneMotion Glossary of Terms to the Additional Documentation table. Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 99
NC-E Series A NC-E Series A NC-E Series B NC-E Series B NC-S NC-S Hazards, electrical DC Power Requirements High-Level Controller Ethernet Switch configure NC LITE identification NC-12 Host Controller NC-E Series B Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 100
Manual temperature Additional Resources NC-E Series A prerequisites connectors safety notices digital I/O Motor, identification dimensions Mounting DIN rail mounting NC LITE exclusion zones NC LITE power supply IP rating NC-12 labels Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 101
Temperature overview NC LITE service access NC-12 set IP Address NC-E either Series A or B shipping NC-S site lighting Terminal Emulator Requirements troubleshooting Transport System types components Node Controller Configuration File, create Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 102
MagneMover LITE QuickStick software Troubleshooting communications initial node controller Unpacking Vehicle Web Browser Requirements Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 103
Node Controller Hardware User Manual User Manual Rockwell Automation Publication MMI-UM013D-EN-P - August 2024...
Page 104
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Allen-Bradley, expanding human possibility, MagneMotion, MagneMover LITE, QuickStick, QuickStick HT, Rockwell Automation, Stratix, and SYNC IT are trademarks of Rockwell Automation, Inc. EtherNet/IP is a trademark of ODVA.
Need help?
Do you have a question about the Allen-Bradley 700-0871-00 and is the answer not in the manual?
Questions and answers