Electric strike

Advertisement

Quick Links

4500C Series
Electric Strike
Installation Instructions
Product Components
A
4500C Series Electric Strike Body
B
Keeper Shims & Screws
(#4-40 x 1/8" and #4-40 x 3/16")
C
Centerlined and Non-handed
Faceplate for Cylindrical Locksets
D
Offset and Non-handed
Faceplate for Mortise Locksets
E
#12-24 x 1/2" Mounting Screws
F
12 & 24 Volt Plug In Connectors
G
Trim Enhancer & Screws
Electrical Specifications
Electrical Ratings
for Solenoid
Continuous Duty
Voltage
12 VDC
Resistance in Ohms
50
Amps
.24
Solenoids are rated at +/– 10% indicated value.
* 10% max duty cycle (2 min. max on time)
For inductive kickback protection, consider using with the HES 2005M3
SMART Pac
III or 2001M Plug-in Bridge Rectifier with built-in MOV.
®
Minimum Wire Guage Requirements
Voltage
200 feet or less
200–300 feet
300–400 feet
Lengths based on round trip.
Intermittent Duty*
24 VDC
12–16 VAC
24 VAC
200
50
200
.12
.24–.32
.12
12 VDC
24 VDC
18 guage
20 guage
16 guage
18 guage
14 guage
16 guage
A
B
F
G
C
D
E
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the h.e.s. 4500C Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Assa Abloy h.e.s. 4500C Series

  • Page 1 4500C Series Electric Strike Installation Instructions Product Components 4500C Series Electric Strike Body Keeper Shims & Screws (#4-40 x 1/8" and #4-40 x 3/16") Centerlined and Non-handed Faceplate for Cylindrical Locksets Offset and Non-handed Faceplate for Mortise Locksets #12-24 x 1/2" Mounting Screws 12 &...
  • Page 2 Fail Safe mode, THEN CONVERT in accordance with Diagram 4, “Fail Safe Conversion” (see page 3). Preparing the Frame Schlage L9000 and ASSA ABLOY ACCENTRA ™ Diagram 1: 8700 (formerly Yale Commercial) locksets 12 VDC to 24 VDC Conversion must use the template labeled “Schlage...
  • Page 3 Installation (continued) Converting the Diagram 2: Operation Mode Latchbolt Monitor REMOVE the Fire Door Safety White Screw as shown in Diagram 4. Orange NOTE: If no Fire Safety Screw is used the electric strike WILL NOT be fire-rated. Green LOOSEN the two #2-56 screws Diagram 3: located on the back of the strike, Strike Monitor...
  • Page 4 Printed in the U.S.A. Patent pending and/or patent www.assaabloydss.com/patents techsupport.hes@assaabloy.com Copyright © 2024, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company. hesinnovations.com | 800 626 7590 All rights reserved. Reproduction in whole or in part without the express written...