Advertisement

Quick Links

ASTRID
(formerly codenamed SBC-C61)
Single Board Computer
with the NXP i.MX 8M Mini Processors
on 3.5" form factor

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASTRID and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seco ASTRID

  • Page 1 ASTRID (formerly codenamed SBC-C61) Single Board Computer with the NXP i.MX 8M Mini Processors on 3.5” form factor...
  • Page 2: Revision History

    SECO S.p.A. reserves the right to change precise specifications without prior notice to supply the best product possible. For further information on this module or other SECO products, but also to get the required assistance for any and possible issues, please contact us using the dedicated web form available at http://www.seco.com (registration required)
  • Page 3 3.3.6 Optional LED Driver Connector ......................................29 3.3.7 I2C Touch Screen Connector ....................................... 29 ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 4 3.3.16 Boot Mode Select Jumper ........................................38 APPENDICES ....................................39 Thermal Design ............................................40 ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 5 Electrostatic discharges • RoHS compliance • Safety Policy • Terminology and definitions • Reference specifications ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 6: Warranty

    All changes or modifications to the equipment not explicitly approved by SECO S.p.A. could impair the equipment s functionalities and could void the warranty. ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 7: Information And Assistance

    A RMA Number will be sent within 1 working day (only for on-line RMA requests). ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 8: Electrostatic Discharges

    Check carefully that all cables are correctly connected and that they are not damaged. 1.5 Electrostatic discharges The ASTRID board, like any other electronic product, is an electrostatic sensitive device: high voltages caused by static electricity could damage some or all the devices and/or components on-board.
  • Page 9: Safety Policy

    The board shall be powered by a Power Supply Unit separately approved and classified ES1/PS2 according to the requirements of IEC EN 62368-1. ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 10: Terminology And Definitions

    Abbreviation of Physical, it is the device implementing the Physical Layer of ISO/OSI-7 model for communication systems Power Supply Unit Pulse Width Modulation ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 11 User Identity Module, an extension of SIM modules. Universal Serial Bus uSDHC Ultra Secure Digital Host Controller V_REF Voltage reference Pin ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 12: Reference Specifications

    SD Card Association https://www.sdcard.org/home SDIO https://www.sdcard.org/developers/overview/sdio SM Bus http://www.smbus.org/specs USB 2.0 and USB OTG https://www.usb.org/sites/default/files/usb_20_20190524.zip ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 13 • Introduction • Technical specifications • Electrical specifications • Mechanical specifications • Block diagram ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 14 An LTE Cat4 module, Quectel EG-25, with dedicated micro-SIM slot is also available as a factory option The ASTRID board offers two USB 2.0 standard Type-A connectors, an internal header with two additional USB 2.0 Host ports and an USB 2.0 port on micro-AB connector (this interface is shared with the optional modem).
  • Page 15: Technical Specifications

    Optional Shielded Ultra Small Dual Band WiFi 802.11 a/b/g/n/ac with Bluetooth 5.0 Module onboard ** Measured at any point of SECO standard heatsink for this product, during Optional soldered on-board LTE Cat 4 Modem with micro-SIM slot or Telenor any and all times (including start-up). Actual temperature will widely depend eSIM with 5MB Bundle on application, enclosure and/or environment.
  • Page 16: Electrical Specifications

    Batteries supplied with ASTRID board are compliant to requirements of European Directive 2006/66/EC regarding batteries and accumulators. When putting out of order ASTRID, remove the batteries from the board in order to collect and dispose them according to the requirement of the same European Directive above...
  • Page 17: Power Rails

    Storage: 4GB eMMC; Video Interface: eDP; Networking: 2x Gigabit LAN + WiFi with u.FL Connector; ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 18 Reproduction FullHD (*) Idle optimized: Modem not powered, WiFi/BT disabled, Eth0 disabled, video disabled ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 19: Mechanical Specifications

    The printed circuit of the board is made of ten layers, some of them are ground planes, for disturbance rejection. ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 20: Block Diagram

    2.5 Block diagram ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 21 • Introduction • Connectors overview • Connectors description ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 22 3.1 Introduction On ASTRID board, there are several connectors located on the lower plane. Standard connectors are placed on the same side of PCB, so that it is possible to place them on a panel of an eventual enclosure. Please be aware that, depending on the configuration purchased, the appearance of the board could be different from the following pictures.
  • Page 23: Connectors Overview

    CAN1 Bus Termination CN35 Backlight Power selector CAN2 Bus Termination CN52 Boot Mode selector ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 24: Connectors Description

    GBEx_MDI3+/GBEx_MDI3-: Ethernet Controller #x Media Dependent Interface (MDI) I/O differential pair #3. It is the fourth differential pair in Gigabit Ethernet mode; it is not used in 10/100Mbps modes. ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 25 3.3.3 On board WiFi + BT modules The ASTRID board can be equipped with a Dual band (2.4GHz + 5.0 GHz) WLAN 802.11 a/b/g/n/ac + BT 5.0 embedded module, which is Murata Type 1MW, p/n LBEE5HY1MW-230. This optional WiFi + BT module, as a further factory option, can be equipped with a PCB ceramic chip antenna (PulseLarsen W3006) or with an U.FL connector (CN17, type HIROSE U.FL-R-SMT1(10) )for external antenna.
  • Page 26 LVDS_1_TX1+/ LVDS_1_TX1-: LVDS Channel #1 differential data pair #1. TOUCH_SDA TOUCH_INT# LVDS_1_TX2+/ LVDS_1_TX2-: LVDS Channel #1 differential data pair #2. ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 27 +12V Since the use of jumpers in environments with vibrations issues could be a problem, it is possible to provide ASTRID boards with the LCD Power and Backlight Power fixed at the desired value. For this purpose, some dedicated 0-Ohm resistors can be mounted (factory default: not available). Please contact you local Sales rep in case you need this special configuration.
  • Page 28: Edp Connector

    BKLT_PWM: this signal can be used to adjust the backlight brightness in displays supporting eDP_ML2N Pulse Width Modulated (PWM) regulations (LCD_PWR electrical level). eDP_ML3P eDP_ML3N LCD_PWR ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 29 The signals available on this connector are exactly the same available on LVDS connector CN40. Please look at par. 3.3.4. TOUCH_SDA for their description. TOUCH_SCL TOUCH_RST ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 30 When connecting CSI cameras to CN16 connector, it is strongly recommended to use shielded cable for EMC compatibility. ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 31: Usb Connectors

    10KΩ pull-up resistor. Please be aware that the USB Host mode on CN36 is allowed only if the ASTRID board is not equipped with the optional Modem module. The second USB interface is carried to a Microchip USB2514 USB2.0 Hub, which makes available four USB Dual USB 2.0 Type-A Socket...
  • Page 32: Audio Connectors

    These connectors are type MOLEX 53398-0571 or equivalent, with the pinouts shown in the tables in the next page. Mating connectors: MOLEX 51021-0500 receptacle with MOLEX 50079-8000 female crimp terminals. ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 33: Serial Ports Connectors

    M4_DUART_RX: UART port #4 Receive signal, VDD_3V3 electrical level. VDD_3V3 M4_DUART_RX M4_DUART_TX: UART port #4 Transmit signal, VDD_3V3 electrical level. M4_DUART_TX ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 34 This means that there are 16 possible configurations of these interfaces. Please be aware that the board’s configuration with ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 35: Factory Option

    RS232_1_TX : COM Port #3 RS-232 Mode Transmit data RS232_1_RTS : COM Port #3 RS-232 Mode Request to Send handshaking signal. ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 36 OUT4 ECSPI1_SS0 CN51-6 OUT5 ECSPI2_MOSI CN51-7 OUT6 ECSPI2_MISO CN51-8 OUT7 ECSPI2_SCLK CN51-9 OUT8 ECSPI2_SS0 ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 37 JTAG_TMS documentation for a description of the signals and their usage. JTAG_TDI JTAG_TDO JTAG_TRST_B ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 38 FLASH device or for debug purposes. ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 39 • Thermal Design ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.
  • Page 40: Thermal Design

    When using ASTRID boards, it is necessary to consider carefully the heat generated by the module in the assembled final system, and the scenario of utilization. Until the board is used on a laboratory shelf, on free air, just for software development and system tuning, then a heatsink with integrated fan could be sufficient for board’s cooling.
  • Page 41 52100 Arezzo - ITALY Ph: +39 0575 26979 - Fax: +39 0575 350210 www.seco.com ASTRID ASTRID User Manual - Rev. First Edition: 1.0 - Last Edition: 1.4 - Author: S.B. - Reviewed by N.P. - Copyright © 2022 SECO S.p.A.

Table of Contents