Contents General Description....................1 Major Features ....................1 Specification ......................2 Unpacking the Instrument ..................2 Standard Accessories ..................2 Optional Accessories..................3 Optional Reagents and HACH Cross Reference ..........3 Installation......................4 Battery Installation ..................4 Instruction Overview ....................5 Control Keys ....................5 Main Module On/Off ..................6 Measurement ......................6 Supported Methods ..................6 Measurement Procedure ................6 Calibration ......................8...
Page 3
Pyxis Lab Inc. Standard Limited Warranty Pyxis Lab warrants its products for defects in materials and workmanship. Pyxis Lab will, at its option, repair or replace instrument components that prove to be defective with new or remanufactured components (i.e., equivalent to new). The warranty set forth is exclusive and no other warranty, whether written or oral, is expressed or implied.
The SP-208 is factory calibrated & may be field calibrated utilizing our Pyxis DPD Chlorine Secondary Standard Solution (1 or 2ppm). For rapid accuracy verification, users may also desire to utilize the Pyxis DPD Chlorine Secondary Verification Kits (LR and HR). These kits consist of pre-made vials set to a specific chlorine concentration.
2 Specification *NOTE* Specifications are subject to change without notice. Contact Pyxis (service@pyxis- lab.com) for an updated specification list. Item SP-208 OXI-GO 63068 Low Chlorine Range 0.02-2.2mg/L (Free or Total Chlorine) High Chlorine Range 0.1-10.0mg/L (Free or Total Chlorine) Temperature Range...
4 Installation 4.1 Battery Installation The SP-208 is powered by 4 AA alkaline batteries. The 4 AA alkaline batteries will last sufficient for approximately 10,000 measurements. When the battery capacity is critically low, the SP-208 will display a LOW BATTERY warning for 5 seconds and then automatically turn off.
5 Instruction Overview Figure 2 5.1 Control Keys The SP-208 has three control keys, as shown in Figure 2. The left ( ), right ( ), and ok ) keys are used to launch actions indicated on the LCD display directly above the keys. The labels above the keys indicate the function associated with each key and functions can be changed in different operation modes.
5.2 Main Module On/Off To turn on the SP-208, press momentarily and release. To turn off the SP-208, press and hold the key. Release the key when the LCD display turns off. The SP-208 turns itself off after 60 seconds without user interaction detected. This is done to conserve battery life.
7 Calibration The method has been calibrated prior to shipping, there is no need to calibrate unless a calibration check indicates that the method needs a calibration. The following steps are used to calibrate a method: Each method has been calibrated prior to shipping, there is no need to calibrate unless a calibration check indicates that the method needs a calibration.
Figure 7 Figure 8 Figure 9 Figure 10 8 Device Information and Diagnosis The Information screen is launched when System ( ) is pressed while not in an ongoing measurement procedure. This screen contains the device serial number, software version, and hardware version (Figure 18).
(Figure 13). The information has no use for normal operation, but instead is used for device troubleshooting. Provide an image of both the Information screen and the diagnosis screen when you contact service@pyxis-lab.com for troubleshooting your device or call +1 (866) 203-8397.
8.2 Factory Reset Use the following steps to restore all device parameters to factory default: Power on the SP-208 by pressing Press System ( ) as needed to launch the Information screen as show in figure. Press Diag ( ) to launch the diagnosis screen. The display updates as shown in Figure 13.
1. Follow the steps in the Bluetooth Connection to Devices section to make the SP-208 discoverable. 2. Open uPyxis® Mobile App. 3. On uPyxis® Mobile App, pull down to refresh the list of available Pyxis devices. 4. If the connection is successful, the SP-208 and its Serial Number (SN) will be displayed (Figure 16).
9.3 Setting Screen From the Setting screen (Figure 17), the user can set the Power off time and Screen off time in seconds. Figure 17 Figure 18 System Screen When connected, the uPyxis® Mobile App will default to the System screen (Figure 18). From the System screen, users can change the Device Name, find the Serial Number, Hardware Version, and Firmware Version, as well as update the firmware of the SP-208 by pressing Check...
Datalog Screen From the Datalog screen, the user can view and export the internal log files of the SP-208 by pressing Read Datalogs and selecting the desired datalog (these are separated by month). The SP-208 will then populate any relevant log event from the selected datalog which can be viewed in more detail by pressing Read Record or exported as a CSV document by...
10.1 Install uPyxis® Desktop App Download the latest version of uPyxis® Desktop software package from: https://pyxis- lab.com/upyxis/ this setup package will download and install the Microsoft.Net Framework 4.5 (if not previously installed on the PC), the USB driver for the MA-NEB USB-Bluetooth adapter (P/N: MA-NEB) and the main uPyxis®...
Once connected to the device, a picture of the device will appear on the top-left corner of the window and the uPyxis® Desktop App will default to the System screen. From the System screen, users can upgrade the firmware by selecting an appropriate firmware file (contact service@pyxis-lab.com for these firmware files) and clicking Upgrade Firmware.
10.5 Datalog Screen From the Datalog screen, the user can view, delete, and export the internal log files of the SP- 208 by clicking Read Datalog List and selecting the desired datalog (these are separated by month). The SP-208 will then populate any relevant log event from the selected datalog which can be viewed in more detail by clicking Read Datalog, deleted by clicking Delete, or...
11 Device Maintenance and Precaution 11.1 Maintenance Best Practices and Quick Tips For greatly increased working life and ease of use of the SP-208 follow the list of maintenance best practices and quick tips below: • Use a soft cloth or lint free paper tissue to clean the sample vial compartment periodically.