Zapi ACE3 User Manual page 43

Hide thumbs Also See for ACE3:
Table of Contents

Advertisement

2) SET POT BRK MAX (Only for TRACTION)
It records the maximum value of braking pedal potentiometer when the
braking pedal is fully pressed; the procedure is similar to the "Program Vacc"
function (see chapter 9.4). This procedure must be carried out only if the
"A10 Function" option is programmed as "BRAKE".
3) MIN LOWER (Only for PUMP)
It records the minimum value of lower potentiometer when the lower switch is
closed; the procedure is similar to the "Program Vacc" function (see chapter
9.4).
4) MAX LOWER (Only for PUMP)
It records the maximum value of lower potentiometer when the lower switch
is closed; the procedure is similar to the "Program Vacc" function (see
chapter 9.4).
5) SET BATTERY TYPE
It selects the nominal battery voltage.
6) ADJUST KEY VOLT
Fine adjustment of the key voltage measured by the controller.
7) ADJUST BATTERY
Fine adjustment of the battery voltage measured by the controller.
8) SET POSITIVE PEB
It sets the voltage connected to CNA-17.
9) THROTTLE 0 ZONE
It establishes a deadband in the accelerator input curve (see chapter 9.4)
10) THROTTLE X1 MAP
This parameter changes the characteristic of the accelerator input curve.
(see chapter 9.4)
11) THROTTLE Y1 MAP
This parameter changes the characteristic of the accelerator input curve.
(see chapter 9.4)
12) THROTTLE X2 MAP
This parameter changes the characteristic of the accelerator input curve.
(see chapter 9.4)
13) THROTTLE Y2 MAP
This parameter changes the characteristic of the accelerator input curve.
(see chapter 9.4)
14) THROTTLE X3 MAP
This parameter changes the characteristic of the accelerator input curve.
(see chapter 9.4)
15) THROTTLE Y3 MAP
This parameter changes the characteristic of the accelerator input curve.
(see chapter 9.4)
AFFZP0BA – ACE3 - User Manual
Page - 43/92

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACE3 and is the answer not in the manual?

Table of Contents