1.4 Specifications
Extension Card
CS (1 unit)
PT-interface CS (1 unit)
ISDN Extension
VPS (1 port)
*1
Only the extension cards that can support SLTs count for the MEC figures.
Calculation Example (KX-TDA100)
KX-T7600 series DPT
SLC16
MSLC16
VPS
Total
The total MEC figure is 88. As this exceeds 64, you need to install an MEC card for this configuration.
Power Supply Unit Selection
The Hybrid IP-PBX needs an optional power supply unit (PSU) suitable for its configuration. Calculate the
load figure from the type and number of items of equipment to be connected, and determine the type of PSU
that will be required.
Load Figure Calculation
PT
Extension Card
34
Installation Manual
Equipment Type
*1
DHLC8
SLC8
SLC16
MSLC16
Equipment Type
Equipment Type
KX-T7600 series DPT/DSS console
KX-T7560/KX-T7565 DPT
Other DPT/DSS console
APT
IP-PT
*1
DHLC8
SLC8
SLC16
MSLC16
48 units
1 card
1 card
8 ports
MEC Figure
8
8
16
16
0
0
0
1
MEC Figure
48
16
16
8
88
Load Figure
1
1
4
4
0
8
8
16
16