Rectifying faults
Warnings
Error 57: Slave tacho error
Category B
Fault in the wire f eeder (slave drive).
Check the connections (connectors, lines).
Permanent overload of the wire drive (slave drive).
Do not lay the liner in tight radii.
Check the liner f or ease of movement.
Error 58: Short circuit
Category B
Short circuit in the welding circuit.
Eliminate the short circuit in the welding circuit.
Place the welding torch on an insulated surface.
Error 59: Incompatible machine
A machine connected to the system is not compatible.
Disconnect the incompatible machine from the system.
Error 60: Incompatible software
The sof tware of a machine is not compatible.
Disconnect the incompatible machine from the system
Request service.
Error 61: Welding monitoring
The actual value of a welding parameter is outside the specified tolerance range.
Maintain the tolerance ranges.
Adjust the welding parameters.
Error 62: System component
The system component was not found.
Request service.
Error 63: Mains voltage error
Operating and mains voltage are incompatible.
Check or adjust the operating and mains voltage.
[1]
See technical data for values and other switching thresholds.
7.3
Warnings
Depending on the display options of the machine display, a warning message is displayed as follows:
Display type - machine control
Graphic display
two 7-segment displays
one 7-segment display
The cause of the warning is indicated by a corresponding warning number (see table).
• In case of multiple warnings, these are displayed in sequence.
• Document machine warning and inform service personnel, if required.
Warning
1 Excess temperature
76
Display
Potential cause / remedy
A shutdown is imminent due to excess temperature.
099-5TLPXQ-EW501
15.12.2022
Need help?
Do you have a question about the M3.7X-O and is the answer not in the manual?
Questions and answers