Rectifying faults

Resetting JOBs (welding tasks) to the factory settings

Warning
34 JOB unknown
35 Excess current on the wire feed
motor slave
36 Slave tacho error
37 FAST bus f ailure
38 Incomplete component infor-
mation
39 Mains half -wave failure
40 Weak power grid
41 Cooling unit not recognised
47 Battery (remote control, type
BT)
[1]
only f or the XQ machine series
[2]
See technical data for values and other switching thresholds.
7.4
Resetting JOBs (welding tasks) to the factory settings
All customised welding parameters that are stored will be replaced by the factory settings.
7.4.1

Resetting a single JOB

78
Potential cause / remedy
JOB selection was not carried out because the JOB number is
unknown.
Excess current detected on wire f eed motor slave (push/push
system or intermediate drive).
Fault of wire feeder - permanent overload of the wire drive
(push/push system or intermediate drive).
Wire f eeder not connected (reset by actuating the automatic cir-
cuit-breaker of the wire feed motor).
Check the XNET component management.
Check supply voltage.
Check supply voltage.
Check the cooling unit connection.
Battery level is low (replace battery)
7s
Figure 7-1
5s
5s
099-5TLPXQ-EW501