How Do You Install Your Oven; E Lectrical Connection - Fagor 5H-730X User Manual

Hide thumbs Also See for 5H-730X:
Table of Contents

Advertisement

Available languages

Available languages

99639111_A_ML.qxp
02/03/2006
H
ow do you install your oven?
Electrical connection
Monophase line 220-240 V ~
16A fuse or differential
Electrical outlet
2-prong receptacle
+ ground lead
IEC Standard 60083
Before making the connection, ensure that the wires in your
electrical set-up have enough cross-sectional area to properly
supply electricity to the appliance (cross-sectional area must be
at least equal to that of the power cable).
The fuse in your set-up must be 16 amperes.
The electrical connection should be performed before the appliance is installed in the
cabinet.
• The oven must be connected with a power cable (standardised) with three 1.5 mm
conductors (1 ph +1 N + ground) that must be connected to a monophase 220-240
V network via a IEC 60083 standardised receptacle (1 ph +1 N + ground lead) or an
all-pole cut-off device with a minimum distance between contact openings of 3 mm.
The safety wire (green-yellow) is connected to the appliance's terminal
be connected to the ground lead of the electrical set-up.
• In the case of connections with an electric receptacle, it must remain accessible
after installation of the appliance.
• The oven's neutral conductor (blue wire) must be connected to the network's
neutral conductor.
16:50
Page 7
circuit breaker
Power cable
length:
approximately 1.5 m
Monophase 20A Meter
220-240 V ~ 50 Hz
EN
2
and must
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5h-730 series

Table of Contents