CAUTION
DO NOT attempt to operate the pump until the Safety,
General Information and Inspection sections of this
manual have been read and thoroughly understood.
CAUTION
DO NOT pump flammable fluids, corrosive chemicals or
fluids containing toxic substances. These fluids can create
potentially dangerous health and environmental hazards.
Contact local authorities for assistance.
CAUTION
This pump uses a water-cooled mechanical seal to
prevent water from seeping into the engine. The passage
of water through the pump casing lubricates the seal and
prevents it from overheating. NEVER operate the pump
without water in the casing as this will cause damage to
the mechanical seal.
BEFORE STARTING
1. Clean the unit, removing dirt and dust, particularly the
engine cooling air inlet, and air filter.
2. Check the air filter for dirt and dust. If air filter is dirty,
replace air filter with a new one as required.
3. Check fastening nuts and bolts for tightness.
4. The QP2TK provides two methods of starting:
a. 12V battery electric start operation (battery tray
measures 10 x 7 x 12 inches).
b. Manual recoil start (on units with serial number
0181and above).
QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 17
STARTING THE ENGINE (ELECTRIC START)
Refer to Figure 9.
1. Ensure the battery cables are connected to the battery
terminals.
2. Ensure the engine ON/OFF stop lever is not in the OFF
position.
3. Move the engine speed control lever to the LOW position
4. Turn the ignition key to the START (ST) position until the
engine starts.
5. Allow the engine to idle for about 10 seconds before
advancing the engine speed control lever to the HIGH
position.
IGNITION
SWITCH
SPEED
CONTROL
LEVER
ON/OFF
STOP LEVER
RECOIL
HANDLE
Figure 9. Starting the Engine
CAUTION
ALWAYS run engine at full speed while pumping.