STARTING PROCEDURE
WARNING
DO NOT attempt to operate this concrete pump until
the Safety Information, General Information, and
Inspection sections have been read and understood.
1. Locate the emergency stop switch (Figure 21) on
the digital control panel. Turn the emergency stop
switch clockwise and release (open). This will allow
the engine to start.
Figure 21. Emergency Stop Switch
NOTICE
If the emergency stop switch is in the closed position
(STOP), the engine will not start. To start the engine, make
sure the emergency stop switch is in the OPEN (fully
extended) position.
2. Place the cylinder stroke control switch in the
AUTOMATIC position (Figure 22).
AUTOMATIC
Figure 22. Cylinder Stroke Control Switch
(Automatic)
3. Place the pumping control switch in the CENTER OFF
position (Figure 23) for normal pumping operation.
LOCAL
CENTER
Figure 23. Pumping Control Switch (OFF)
PAGE 34 — MAYCO LS450 CONCRETE PUMP • OPERATION MANUAL — REV. #2 (02/23/21)
JOG
REMOTE
OFF
4. Place the direction control switch in the FORWARD
position (Figure 24).
FORWARD
Figure 24. Direction Control Switch
(FORWARD)
5. To start the engine, insert the ignition key (Figure 25)
into the ignition switch and turn the key to the ON
position.
OFF
OFF
IGNITION
IGNITION
Figure 25. Ignition Switch
6. When the ignition key is in the ON position, the digital
readout screen (primary) will cycle through 3 displays
as shown in Figure 26.
450
450
450
Figure 26. Primary Screen (Ignition Key ON)
7. Turn the key to the START position and listen for the
engine to start. In warm weather, let the engine warm
up for 5 minutes. In cold weather, let the engine warm
up for 10 minutes.

OPERATION

REVERSE
ON
ON
START
START